GB/T 32346.2-2015 English PDFUS$489.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 32346.2-2015: Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um=252 kV) -- Part 2: Long AC submarine cables Status: Valid
Basic dataStandard ID: GB/T 32346.2-2015 (GB/T32346.2-2015)Description (Translated English): Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um=252 kV) -- Part 2: Long AC submarine cables Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K13 Classification of International Standard: 29.060.20 Word Count Estimation: 23,266 Date of Issue: 2015-12-31 Date of Implementation: 2016-07-01 Quoted Standard: GB/T 2951.11-2008; GB/T 2951.12-2008; GB/T 2951.21-2008; GB/T 2951.31-2008; GB/T 3048.4; GB/T 3048.8; GB/T 3048.11; GB/T 3048.12; GB/T 3048.13; GB/T 3082-2008; GB/T 3280-2007; GB/T 3956-2008; GB/T 4909.3-2009; GB/T 9771-2008; GB/T 12357-2004; GB/T 15065-2009; GB/T 15972 Regulation (derived from): State Standard Announcement 2015 No.43 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the types, materials, technical requirements, tests, acceptance rules, loading and unloading rules for 220 kV (Um = 252 kV) XLPE insulated large-length AC submarine cables (the following submarine cables refer to AC submarine cables). Storage and transportation. This standard is applicable to large-size submarine cables of rated voltage 220 kV (Um = 252 kV) single-core, three-core XLPE insulation and optical fiber composite XLPE insulated for submarine laying and operating conditions. This standard does not apply to dynamic cables such as offshore floating platforms. GB/T 32346.2-2015: Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um=252 kV) -- Part 2: Long AC submarine cables---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Long AC submarine cables with cross-linked polyethylene insulation and their accessoried for rated voltage of 220 kV (Um = 252 kV) - Part 2. Long AC submarine cables ICS 29.060.20 K13 National Standards of People's Republic of China Rated voltage of 220kV (Um = 252kV) crosslinked poly Vinyl-insulated large length AC submarine cables and accessories Part 2. Large AC submarine cable length accessoriedforratedvoltageof220kV (Um = 252kV) - Part 2. LongACsubmarinecables Issued on. 2015-12-31 2016-07-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 Use Characteristics 2 5 3 Product Naming 6 material and technical requirements 5 Finished 7 cable mark 10 10 8 Tests and requirements 9 Acceptance Rule 14 Shipment and storage 10 14 After laying test 11 14 Appendix A (informative) XLPE insulation material 15 Performance Annex B (informative) semi-conductive shielding material 16 Performance Annex C (informative) semiconductive jacket material 17 PerformanceForewordGB/T 32346 "rated voltage of 220kV (Um = 252kV) XLPE insulated large length AC submarine cables and accessories" into Three parts. --- Part 1. Test methods and requirements; --- Part 2. Large AC submarine cable length; --- Part 3. submarine cable accessories. This section GB/T Part of 232,346. This section Press GB/T 1.1-2009 given rule drafting. This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee Wire and Cable (SAC/TC213) centralized. This section is drafted. Jiangsu Hengtong high-voltage cable Ltd., Shanghai Electric Cable Research Institute, Ningbo Orient Cable Co., Ltd., the national Wire and cable for Quality Supervision and Inspection Center, ZTT Submarine Cable Company Limited, Qingdao Hanlan Co., Ltd., Fujian Yongfu Engineering Consultants Co. The company, Shanghai on cable Fujikura Cable Co., Ltd, China Power Construction Group ECIDI Limited, China Electric Power Research Institute, Shanghai Sanyuan Cable Accessories Limited. The main drafters of this section. Pan Wenlin, XU Xiaofeng, Zhou Zewei, Immunity From Zhang Jianmin, Ju Zi Rui Song Faxing, Cho Chak, Yang Jianjun, Rao Wenbin, Xu operation. Rated voltage of 220kV (Um = 252kV) crosslinked poly Vinyl-insulated large length AC submarine cables and accessories Part 2. Large AC submarine cable length1 ScopeThis section GB/T 32346 specifies the rated voltage of 220kV (Um = 252kV) XLPE submarine power exchange large length Cable (refer to the following submarine cable AC submarine cable) models, materials, technical requirements, testing, inspection rules, shipment and storage. This section is intended for use in laying and operating conditions of the seabed rated voltage of 220kV (Um = 252kV) single-core, three-core cross-linked poly Vinyl-insulated and XLPE insulated fiber composite long length submarine cables. Note. in line with the provisions of this Part of this section and press the test methods and requirements for inspection of long length submarine cables and accessories can be covered with respect to the scope of accreditation GB/T 32346.1-2015 3.7 large defined length shorter length submarine cables. This section does not apply to cable dynamic offshore floating platform used.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2951.11-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 11. General test side Law --- --- Measurement of thickness and overall dimensions of mechanical tests GB/T 2951.12-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 12. General test side Law --- Thermal aging methods GB/T 2951.21-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 21. elastomeric compounds designed Test method for ozone resistance test --- --- --- Hot set test - Mineral oil immersion test GB/T 2951.31-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 31. Polyvinyl chloride mixture Special test methods --- --- high temperature pressure test for resistance to cracking GB/T 3048.4 wire and cable electrical performance test methods - Part 4. Conductor DC resistance test GB/T 3048.8 wire and cable electrical performance test methods - Part 8. AC voltage test GB/T 3048.11 wire and cable electrical performance test methods - Part 11. dielectric loss tangent test GB/T 3048.12 wire and cable electrical performance test methods - Part 12. Partial discharge test GB/T 3048.13 wire and cable electrical performance test methods - Part 13. impulse voltage test method GB/T 3082-2008 armored cable with galvanized or galvanized -5% aluminum - rare earth alloy coated low carbon steel wire GB/T 3280-2007 cold-rolled stainless steel sheet and strip GB/T 3956-2008 conductor cable GB/T 4909.3-2009 Test methods for bare wires - Part 3. Tensile Test GB/T 6995.2-2008 wire and cable identification methods - Part 2. Standard colors GB/T 9771-2008 communication with single-mode fiber (all parts) GB/T 12357-2004 communication with multimode fiber (all parts) GB/T 15065-2009 black polyethylene plastic wire and cable ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 32346.2-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 32346.2-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 32346.2-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32346.2-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |