Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 28518-2012 English PDF

US$419.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 28518-2012: Flame resistant optical fibre cables for communication for mine
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 28518-2012419 Add to Cart 3 days Flame resistant optical fibre cables for communication for mine Valid

Similar standards

YD/T 2554.1   GB/T 9771.1   GB/T 20186.1   GB/T 28511.1   GB/T 28511.2   GB/T 28515.2   

Basic data

Standard ID: GB/T 28518-2012 (GB/T28518-2012)
Description (Translated English): Flame resistant optical fibre cables for communication for mine
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: M33
Classification of International Standard: 33.180.10
Word Count Estimation: 18,124
Quoted Standard: GB/T 2951.11-2008; GB/T 2951.12-2008; GB/T 2951.42-2008; GB/T 3280; GB/T 6995.2; GB/T 7424.2-2008; GB/T 9771-2008; GB/T 12357.1-2004; GB/T 15972.20-2008; GB/T 15972.40-2008; GB/T 15972.43-2008; GB/T 15972.44-2008; GB/T 15972.45-2008; GB/T 18380.12-2008; G
Regulation (derived from): National Standards Bulletin No. 13 of 2012
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the coal mine fire communications cable (hereinafter referred to as fiber optic cable) classification, structure, technical requirements, test methods, inspection rules, marking, packaging and storage. This standard applies to coal

GB/T 28518-2012: Flame resistant optical fibre cables for communication for mine

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Flame resistant optical fibre cables for communication for mine ICS 33.180.10 M33 National Standards of People's Republic of China Coal mine fire communications cable Issued on. 2012-06-29 2012-10-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China. The standard by the China Communications Standards Association. This standard was drafted. China Electronics Technology Group Corporation No.8 Research Institute, China Coal Research Institute Shanghai Branch of light through Group Co. The company, Huainan City of Anhui Province Quality and Technical Supervision. The main drafters of this standard. Yang valuable, Liu Minhua, Xiaoyue Xia, Hu Zhanhua, Huang Junhua, Wang Quan. Coal mine fire communications cable

1 Scope

This standard specifies the Coal mine fire communications cable (hereinafter referred to as cable) classification, structure, technical requirements, test methods, inspection rules, Logo, packaging and storage. This standard applies to coal mine communication cable, is also applicable to other mine communications cable with flame retardant requirements.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2951.11-2008 and optical cables - Common test methods for insulating and sheathing materials Part 11. General test method Part 11. Measurement of thickness and overall dimensions of mechanical tests (IEC 60811-1-1.2001, IDT) GB/T 2951.12-2008 and optical cables - Common test methods for insulating and sheathing materials Part 11. General test method Part 12. Thermal aging test (IEC 60811-1-2.2001, IDT) GB/T 2951.42-2008 cable and the cable Common test methods for insulating and sheathing materials Part 42. polyethylene and polypropylene Mixture special heat treatment after the test method of tensile strength and elongation at break after winding test at high temperature hot air aging test Increase the quality of the winding test measures the long-term thermal stability test Test methods for copper catalyst oxidative degradation (IEC 60811-4-2.2001, IDT) GB/T 3280 stainless steel cold-rolled sheet and strip GB/T 6995.2 wire and cable identification methods - Part 2. Standard colors Basic test method. GB/T 7424.2-2008 cable Part 2 Generic specification (IEC 60794-1-2.2003MOD) GB/T 9771-2008 singlemode fiber communication GB/T 12357.1-2004 communication with multimode fiber - Part 1. A1 multimode fiber characteristics (IEC 60793-2-10.2002) Part 20 GB/T 15972.20-2008 fiber test methods. Measurement methods and test procedures dimensional parameters attenuation (IEC 60793-1-20.2001, MOD) GB/T 15972.40-2008 fiber test methods - Part 40. Measuring methods for transmission and optical characteristics and testing Program attenuation (IEC 60793-1-40.2001, MOD) GB/T 15972.43-2008 fiber test methods - Part 43. Measuring methods for transmission and optical characteristics and testing Program numerical aperture (IEC 60793-1-43.2001, MOD) GB/T 15972.44-2008 fiber test methods - Part 44. Measuring methods for transmission and optical characteristics and testing Program cutoff wavelength (IEC 60793-1-44.2001, MOD) GB/T 15972.45-2008 fiber test methods - Part 45. Measuring methods for transmission and optical characteristics and testing Program mode field diameter (IEC 60793-1-45.2001, MOD) GB/T 18380.12-2008 burning test and optical fiber cables under fire conditions - Part 12. single insulated wire and cable fire Test 1kW pre-mixed flame spread vertical flame test methods (IEC 60332-1-2.2004, IDT) GB/T 18380.35-2008 and optical fiber cables under fire conditions - Test - Part 35. Vertical mounted bunched wires Cable vertical flame spread test Class C (IEC 60332-3-24.2000, IDT) AQ1043-2007 mining product safety signs logo
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 28518-2012_English be delivered?

Answer: Upon your order, we will start to translate GB/T 28518-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 28518-2012_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 28518-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.