GB/T 25915.5-2010 English PDFUS$794.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 25915.5-2010: Cleanrooms and associated controlled environments -- Part 5: Operations Status: Valid
Basic dataStandard ID: GB/T 25915.5-2010 (GB/T25915.5-2010)Description (Translated English): Cleanrooms and associated controlled environments -- Part 5: Operations Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: C70 Classification of International Standard: 13.040.35 Word Count Estimation: 40,490 Date of Issue: 1/14/2011 Date of Implementation: 5/1/2011 Quoted Standard: GB/T 25915.1-2010; GB/T 25915.2-2010; GB/T 25915.3-2010; GB/T 25915.4-2010; GB/T 25915.6-2010; GB/T 25916.1-2010; GB/T 25916.2-2010 Adopted Standard: ISO 14644-5-2004, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 2 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Standard specifies the basic playing cleanroom run demand for ready to use and run the clean room personnel. This standard does not involve content and pollution control issues are directly related to the safety related issues should comply with national and local safety regulations. This Standard is applicable to the production of a variety of products at all levels of clean room, wide range of applications, but does not involve the specific requirements of various industries. This standard does not include details of the cleanroom conventional monitoring methods and planning, monitoring on particle see GB/T 25915. 2 and GB/T 25915. 3, microbiological monitoring See GB/T 25916. 1 and GB/T 25916. 2. GB/T 25915.5-2010: Cleanrooms and associated controlled environments -- Part 5: Operations---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Cleanrooms and associated controlled environments Part 5. Operations ICS 13.040.35 C70 National Standards of People's Republic of China Cleanroom and associated controlled environments Part 5. Run Part 5. Operations (ISO 14644-5.2004, IDT) Issued on. 2011-01-14 2011-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsPreface Ⅰ Introduction Ⅱ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 3 Technical requirements Appendix A (informative) Operation System 5 Annex B (informative) clean clothes 10 Annex C (informative) 14 persons Annex D (informative) fixture 17 Annex E (informative) Materials and portable devices 20 Clean Appendix F (informative) clean room 26 References 34ForewordGB/T 25915 "cleanroom and associated controlled environment" is divided into eight sections. --- Part 1. air cleanliness level; --- Part 2. prove continued compliance with the GB/T 25915.1 detection and monitoring of technical conditions; --- Part 3. Detection; --- Part 4. design, construction, start-up; --- Part 5. Run; --- Part 6. Vocabulary; --- Part 7. isolation device (clean hoods, glove boxes, isolators, micro-environment); --- Part 8. Classification of air pollution molecules. This part of GB/T 25915 Part 5. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the translation method identical with ISO 14644-5.2004 "clean rooms and associated controlled environments - Part 5. Run." This part of the National Clean rooms and associated controlled environments Standardization Technical Committee (SAC/TC319) and focal points. This part by the Tianjin Ryongchon purification Engineering Co., Ltd. Shenzhen Geelong clean technologies, Civil Engineering and Mechanics, Yanshan University Science School is responsible for drafting, Beijing Hedo Construction Supervision Co., Ltd., Environmental Science and Engineering, Tianjin University, Tianjin Institute of Urban Construction, Tianjin Pharmaceutical Group Corporation, Shanghai morning-long International Trade Co., Ltd., Suzhou Huatai Air Filter Co., Ltd. participated in the drafting. The main drafters of this section. coated, Zhang Lihai, Huangji Hui, Tu equipment, Shi Zengde, Lu Jian, Xing Jincheng, Ling Jihong, Wang Shungang, Zhang Xin, Zhang Yan, Huang Jianhua, Wei Xiaobo, Huang Qiang, Wen Jige, Zhaoqiu Hua.IntroductionCleanroom widely used in various industries. Operating procedures for the production of clean room equipment to run its clean room cleaning operation can be achieved Clarity has an important influence. Cleanliness determine the stability of quality. Only careful working out a plan, the provisions in the plan, implement and test the determined And operating procedures, timely detect and enforce detailed regulations to run the system in order to achieve and maintain the cleanliness of the work required. this It is a standard part of the general operation of common file for all types of clean rooms, some responsible for the cleanroom technology and related products machine regulations Configuration may also increase the number of procedures and requirements attached inspection measures in this part of the general operating standards are not covered. GB/T 25915 in this part of the developed related to the following recommended normative and operational requirements. a) develop principles proposed system contains policies and operating procedures; b) produced by the body to be used for blocking dirt contamination and clean room environment isolated clean clothes; c) training of staff in the clean room staff, and supervise and monitor their compliance with the rules and discipline of the situation; d) fixing devices (not standard equipment includes fixed) moving, installation and maintenance; e) selection and use of clean room materials and portable devices; f) cleaning and maintaining the systematic monitoring of clean room cleanliness. Cleanroom and associated controlled environments Part 5. Run1 ScopeThis section GB/T 25915 specifies the basic requirements for cleanroom operation, ready for use and operation of the clean room personnel. this No part of the contents relates to pollution control are directly related to security issues, questions should comply with national and local safety regulations. This section Involving all levels of production of various kinds of cleanroom products, wide range of applications, but relates to the specific requirements of various industries. This section does not include Details of conventional monitoring methods and planning cleanroom see on monitoring particles GB/T 25915.2 and GB/T 25915.3, microorganisms Monitoring See GB/T 25916.1 and GB/T 25916.2.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 25915.1-2010 cleanroom and associated controlled environments - Part 1. air cleanliness level (ISO 14644-1.1999, IDT) GB/T 25915.2-2010 cleanroom and associated controlled environments - Part 2. prove continued compliance with the GB/T 25915.1 detection Monitoring and technical requirements (ISO 14644-2.2000, IDT) GB/T 25915.3-2010 cleanroom and associated controlled environments - Part 3. Detection method (ISO 14644-3.2005, IDT) GB/T 25915.4-2010 cleanroom and associated controlled environments - Part 4. Design, construction, start (ISO 14644-4.2001, IDT) GB/T 25915.6-2010 cleanroom and associated controlled environments - Part 6. Vocabulary (ISO 14644-6.2007, IDT) GB/T 25916.1-2010 cleanroom and associated controlled environments Biological Pollution Control Part 1. General principles and methods (ISO 14698-1.2003, IDT) GB/T 25916.2-2010 cleanroom and associated controlled environments Biological Pollution Control Part 2. Evaluation of biological contamination data And analysis (ISO 14698-2.2003, IDT)3 Terms and DefinitionsThe following terms and definitions apply to this document. 3.1 General terms 3.1.1 Biological clean room biocleanroom Products and cleanroom technology for microbial contamination of sensitive uses. 3.1.2 Dressing changingroom When out of the clean room personnel wear clean clothes off the room. [GB/T 25915.4-2010,3.1] ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 25915.5-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 25915.5-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 25915.5-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 25915.5-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |