GB/T 25915.2-2021 PDF EnglishUS$260.00 · In stock · Download in 9 seconds
GB/T 25915.2-2021: Cleanrooms and associated controlled environments - Part 2: Monitoring to provide evidence of cleanroom performance related to air cleanliness by particle concentration Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB/T 25915.2: Historical versions
Similar standardsGB/T 25915.2-2021: Cleanrooms and associated controlled environments - Part 2: Monitoring to provide evidence of cleanroom performance related to air cleanliness by particle concentration---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT25915.2-2021 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 13.040.35 CCS C 70 GB/T 25915.2-2021 / ISO 14644-2:2015 Replacing GB/T 25915.2-2010 Cleanrooms and associated controlled environments - Part 2: Monitoring to provide evidence of cleanroom performance related to air cleanliness by particle concentration (ISO 14644-2:2015, IDT) ISSUED ON: AUGUST 20, 2021 IMPLEMENTED ON: MARCH 01, 2022 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of ContentsForeword ... 3 Introduction ... 5 1 Scope ... 8 2 Normative references ... 8 3 Terms and definitions ... 8 4 Creating, implementing and maintaining a monitoring plan ... 9 5 Periodic classification of air cleanliness by particle concentration ... 12 Annex A (Informative) Matters to consider when developing a monitoring plan ... 13 Annex B (Informative) Considerations for setting alert and action levels ... 17 Bibliography ... 23ForewordThis document was drafted in accordance with the rules given in GB/T 1.1-2020, Directives for standardization - Part 1: Rules for the structure and drafting of standardizing documents. This document is Part 2 of GB/T 25915, Cleanrooms and associated controlled environments. The following parts have been issued for GB/T 25915: -- Part 1: Classification of air cleanliness by particle concentration; -- Part 2: Monitoring to provide evidence of cleanroom performance related to air cleanliness by particle concentration; -- Part 3: Test methods; -- Part 4: Design, construction and start-up; -- Part 5: Operations; -- Part 6: Vocabulary; -- Part 7: Separative devices (clean air hoods, gloveboxes, isolators and minienvironments); -- Part 8: Classification of air cleanliness by chemical concentration (ACC); -- Part 9: Classification of surface cleanliness by particle concentration; -- Part 10: Classification of surface cleanliness by chemical concentration; -- Part 12: Specifications for monitoring of air cleanliness by nanoscale particle concentration. This document replaces GB/T 25915.2-2010, Cleanrooms and associated controlled environments - Part 2: Specifications for testing and monitoring to prove continued compliance with GB/T 25915.1. Compared with GB/T 25915.2-2010, the main technical changes are as follows: a) Modify the scope (see Chapter 1; Chapter 1 of the 2010 edition); b) In terms and definitions, keep only the original two terms, test and monitoring; delete the other six terms (see Chapter 3 of the 2010 edition); add two terms, action level and alert level (see 3.3 and 3.4); c) Change “Demonstration of maintaining the requirements” to “Creating, implementing and maintaining a monitoring plan” (see Chapter 4; Chapter 4 of the 2010 edition); Cleanrooms and associated controlled environments - Part 2: Monitoring to provide evidence of cleanroom performance related to air cleanliness by particle concentration1 ScopeThis document specifies minimum requirements for a monitoring plan. This monitoring plan is for cleanroom or clean zone performance related to air cleanliness by particle concentration, based upon parameters that measure or affect airborne particle concentration. This document applies to the monitoring of particle concentration of particle-size range 0.1 μm ~ 5 μm. This document does not address condition monitoring of aspects such as vibration or general maintenance of the engineering systems. Concentrations of ultrafine particles (particles smaller than 0.1 μm) will be addressed in a separate standard.2 Normative referencesThe following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 25915.1-2021, Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness by particle concentration (ISO 14644-1:2015, MOD) Note: There is no technical difference between the content cited in GB/T 25915.1-2021 and the content cited in ISO 14644-1:2015.3 Terms and definitionsFor the purposes of this document, the terms and definitions given in GB/T 25915.1- 2021 and the following apply: 3.1 ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. |