GB/T 25915.4-2010 English PDFUS$874.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 25915.4-2010: Cleanrooms and associated controlled environments -- Part 4: Design, construction and start-up Status: Valid
Basic dataStandard ID: GB/T 25915.4-2010 (GB/T25915.4-2010)Description (Translated English): Cleanrooms and associated controlled environments -- Part 4: Design, construction and start-up Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: C70 Classification of International Standard: 13.040.35 Word Count Estimation: 44,415 Date of Issue: 1/14/2011 Date of Implementation: 6/1/2011 Quoted Standard: GB/T 25915.1-2010; GB/T 25915.2-2010; GB/T 25915.3-2010; GB/T 25916.1-2010; GB/T 25916.2-2010 Adopted Standard: ISO 14644-4-2001, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 2 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Standard specifies clean room facility design and construction requirements, but does not provide the means to meet those specific technical or contractual requirements needed. This standard also gives an important performance parameter catalog, together with supply and demand side of cleanroom facilities, suppliers and designer to use. This standard gives guidelines include starting construction and validation requirements. In considering the operation and maintenance of related matters identified to ensure continued satisfactory operation of the design and construction of basic elements. GB/T 25915.4-2010: Cleanrooms and associated controlled environments -- Part 4: Design, construction and start-up---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Cleanrooms and associated controlled environments Part 4. Design, construction and start-up ICS 13.040.35 C70 National Standards of People's Republic of China Cleanroom and associated controlled environments Part 4. Design, construction, start Part 4. Design, constructionandstart-up (ISO 14644-4.2001, IDT) Issued on. 2011-01-14 2011-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsPreface Ⅰ Introduction Ⅱ 1 Scope 1 2 References 1 3 Terms and definitions 4 requires 2 5 Planning and Design 3 Construction and start 4 6 7 testing and inspection 4 8 file 4 Concepts Appendix A (informative) control and isolation of 7 Annex B (informative) Example 13 rating Acceptance Appendix C (informative) facility 15 Layout Appendix D (informative) facility 18 Annex E (informative) construction and material 21 Annex F (informative) cleanroom environment control 25 Annex G (informative) air cleanliness control 27 Appendix H (informative) be the demand side/user and the supplier/designer agreed additional technical requirements 29 References 37ForewordGB/T 25915 "cleanroom and associated controlled environment" is divided into eight sections. --- Part 1. air cleanliness level; --- Part 2. prove continued compliance with the GB/T 25915.1 detection and monitoring of technical conditions; --- Part 3. Detection; --- Part 4. design, construction, start-up; --- Part 5. Run; --- Part 6. Vocabulary; --- Part 7. isolation device (clean hoods, glove boxes, isolators, micro-environment); --- Part 8. Classification of air pollution molecules. This part of GB /Part 4 T 25915 of. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the translation method identical with ISO 14644-4.2004 "clean rooms and associated controlled environments - Part 4. Design, construction, start move". This part of the National Clean rooms and associated controlled environments Standardization Technical Committee (SAC/TC319) and focal points. This in part by China Electronics Engineering Design Institute, China Petrochemical Corporation Shanghai Engineering Co., Ltd., China Pharmaceutical and Biological Products is responsible for starting Grass, Beijing Hedo Construction Supervision Co., Ltd. Beijing World source Hedo engineering company Shenzhen Austrian Italian Architectural Design Co., Ltd., Shenzhen Xing Electrical and Mechanical Services Branch net decontamination Ltd., Tianjin Ryongchon clean Seiko Technology Development Co., China Alliance contractors Industry Co., Ltd., North Beijing North Tianyu Building Decoration Co., Ltd., Suzhou Industrial Park, Jia Environmental Technology Engineering Co., Ltd., Beijing Aerospace Changfeng Co. Shares The company participated in the drafting. The main drafters of this section. Lou Yu Miao De Hua, Bai Dongting, Suzhou Steel Man, Anzhi star, Liu Na, Yang one, Jiang Yuqin, Zhang Xu, Wang Hongming, Wang Yiping, Chen Lin new, Bao Xia, especially Rong method, strong pine, money Jing, Shi Xiaolei, Zhang Xin, Zhang Yan, Xiao Hongmei, red Swiss mother, Ping Xiong, Tongzhi Fu.IntroductionCleanroom and associated controlled environments in the air particulate matter control at an appropriate level in order to complete the pollution-sensitive jobs. product Art technology and benefit from the control of pollutants are. aerospace, microelectronics, pharmaceuticals, medical devices, health care and other industries. This section GB/T 25915 specifies the requirements for design and construction of clean room facilities for the demand side of the clean room, the supplier and designer to make Use, and provide the main performance parameters of the checklist. This section provides instructions to build, including start-up and requires confirmation. Khao When taking into account issues related to operation and maintenance, a clear basic design and construction requirements to ensure the continued satisfactory operation required. This section is a cleanroom and associated controlled environment of a series of standards. For the operation and control of cleanrooms and other controlled environments, In addition to the design, construction and start-up, there are many factors to consider. Other national standards in these factors in SAC/TC319 developed We have a more detailed discussion. Cleanroom and associated controlled environments Part 4. Design, construction, start1 ScopeThis section GB/T 25915 specifies the requirements for design and construction of cleanroom facilities, but does not provide the tools needed to meet those requirements Technical or contractual means body. This section also gives an inventory of important performance parameters, together with supply and demand side of the clean room facilities, supplier and designer use. This section gives guidelines include the construction start and confirmation requirements. When considering matters related to operation and maintenance, to ensure clear support Continued basic elements satisfactory operation of the design and construction. NOTE. For more information about the above requirements are explained in Appendix H. Appendix A ~ GB/T 25915 other parts also gives additional information. Application of this section are defined as follows. --- User requested by the demand side or the predetermined direction; --- Specific processes within the clean room facilities not specified; --- Without making special for fire and safety regulations, fire protection and safety should comply with applicable national and local regulations; --- It relates only to the route in different regions and between the cleanliness of process media and utilities; --- Only it relates to the construction and initial operation of the clean room related maintenance and specific requirements.2 ReferencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 25915.1-2010 cleanroom and associated controlled environments - Part 1. air cleanliness level (ISO 14644-1.1999, IDT) GB/T 25915.2-2010 cleanroom and associated controlled environments - Part 2. prove continued compliance with the GB/T 25915.1 detection Monitoring and technical conditions (ISO 14644-2.2000, IDT) GB/T 25915.3-2010 cleanroom and associated controlled environments - Part 3. Detection method (ISO 14644-3.2005, IDT) GB/T 25916.1-2010 cleanroom and associated controlled environments Biological Pollution Control Part 1. General principles and methods (ISO 14698-1.2003, IDT) GB/T 25916.2-2010 cleanroom and associated controlled environments Biological Pollution Control Part 2. Evaluation of biological contamination data And analysis (ISO 14698-2.2003, IDT)3 Terms and DefinitionsGB/T 25915.1-2010 and as defined in the following terms and definitions are applicable to this document. 3.1 Dressing changingroom When out of the clean room personnel wear clean clothes off the room. 3.2 Air purification devices cleanairdevice Air purification treatment and distribution, device independent of the environment to achieve a predetermined condition. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 25915.4-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 25915.4-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 25915.4-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 25915.4-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |