GB/T 25386.2-2021 English PDFUS$339.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 25386.2-2021: Wind turbines - Control system - Part 2: Test method Status: Valid GB/T 25386.2: Historical versions
Basic dataStandard ID: GB/T 25386.2-2021 (GB/T25386.2-2021)Description (Translated English): Wind turbines - Control system - Part 2: Test method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: F11 Word Count Estimation: 18,135 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 25386.2-2021: Wind turbines - Control system - Part 2: Test method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Wind turbines - Control system - Part 2.Test method ICS 27.180 F11 National Standards of People's Republic of China Replace GB/T 25386.2-2010 Wind turbine control system Part 2.Test method Released on 2021-03-09 2021-10-01 implementation State Administration of Market Supervision and Administration Issued by the National Standardization Management Committee Table of contentsForeword Ⅰ 1 Scope 1 2 Normative references 1 3 Test environment 2 4 Test preparation 3 5 Test method 3 6 Test report 11 Appendix A (informative appendix) Recommendations for test protocol 12 Appendix B (informative appendix) Requirements for measuring equipment 13 Appendix C (informative appendix) Test report format and content 14 Wind turbine control system Part 2.Test method1 ScopeThis part of GB/T 25386 specifies the test conditions and test methods for wind turbine control systems. This section applies to the grid-connected horizontal axis variable speed constant frequency wind turbine (hereinafter referred to as the "unit") control system.2 Normative referencesThe following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document. GB/T 2423.1-2008 Environmental testing of electric and electronic products Part 2.Test method Test A. Low temperature GB/T 2423.2-2008 Environmental testing of electric and electronic products Part 2.Test method Test B. High temperature GB/T 2423.3 Environmental Test Part 2.Test Method Test Cab. Constant Humidity Test GB/T 2423.4-2008 Environmental testing of electrical and electronic products Part 2.Test method Test Db Alternating damp heat (12h 12h cycle) GB/T 2423.5 Environmental Test Part 2.Test Method Test Ea and Guideline. Impact GB/T 2423.16-2008 Environmental testing of electric and electronic products Part 2.Test method Test J and guideline. Mould GB/T 2423.18-2012 Environmental test Part 2.Test method Test Kb. Salt spray, alternating (sodium chloride solution) GB/T 4208-2017 Enclosure protection grade (IP code) GB/T 7251.1 Low-voltage switchgear and control equipment Part 1.General GB/T 10233-2016 Basic test methods for low-voltage switchgear and electric control equipment GB/T 17626.2 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test GB/T 17626.3 Electromagnetic compatibility test and measurement technology Radio frequency electromagnetic field radiation immunity test GB/T 17626.4 Electromagnetic compatibility test and measurement technology Electrical fast transient pulse group immunity test GB/T 17626.5 Electromagnetic compatibility test and measurement technology surge (impact) immunity test GB/T 17626.6 Electromagnetic compatibility test and measurement technology Radio frequency field induced conducted disturbance immunity GB/T 17626.12 Electromagnetic compatibility test and measurement technology Ring wave immunity test GB/T 18451.1-2012 wind turbine design requirements GB/T 20320-2013 Wind turbine power quality measurement and evaluation method GB/T 20626.1 Special environmental conditions Plateau electrical and electronic products Part 1.General technical requirements GB/T 25386.1-2021 Wind Turbine Control System Part 1.Technical Conditions GB/T 36237 Wind turbine electrical simulation model GB/T 36995-2018 Wind Turbine Generator Fault Voltage Ride Through Capability Test Procedure GB 50054 Low Voltage Power Distribution Design Code NB/T 31053-2014 Wind Turbine Low Voltage Ride Through Modeling and Verification Method NB/T 33011-2014 Distributed power grid connection test technical specification4 Test preparation4.1 The tested control system should have been debugged, and the parameters should meet the relevant unit control and monitoring requirements. 4.2 The various components and sensors involved in the test have been debugged, and their functions and accuracy are in compliance with the relevant unit control, detection and protection requirements. 4.3 The function and dynamic performance of the simulation model participating in the experiment conforms to the actual situation of the simulation object, and the calculation period and communication period conform to the simulation. True accuracy requirements. 4.4 The instruments and meters used in the test should be within the validity period of the verification. For the requirements for measuring equipment, see Appendix B.5 Test method5.1 General inspection Check whether the electrical design and process of the control system meet the requirements of GB/T 50054, GB 7251.1 and GB/T 20626.1, and comply with Comply with the provisions of Chapter 10 of GB/T 18451.1-2012. 5.2 Equipment safety 5.2.1 Protection circuit effectiveness test The effectiveness test of the protection circuit shall be carried out in accordance with the method specified in 4.4 of GB/T 10233-2016. 5.2.2 Degree of protection The protection level test should be carried out in accordance with the methods specified in Chapter 13 and Chapter 14 of GB/T 4208-2017. 5.3 Insulation test 5.3.1 Dielectric performance test The test of dielectric properties should be carried out in accordance with the method specified in 4.5 of GB/T 10233-2016. 5.3.2 Insulation resistance test The insulation resistance measurement should be carried out in accordance with the method specified in 4.6 of GB/T 10233-2016. 5.4 Electromagnetic compatibility test 5.4.1 Ringing wave immunity test The ring wave immunity test should be carried out in accordance with the method specified in GB/T 17626.12. 5.4.2 Electrostatic discharge immunity test The electrostatic discharge immunity test shall be carried out in accordance with the method specified in GB/T 17626.2. 5.4.3 Radio frequency electromagnetic field radiation immunity test The radiated electromagnetic field immunity test should be carried out in accordance with the method specified in GB/T 17626.3. 5.4.4 Electrical fast transient pulse group immunity test The electrical fast transient pulse group immunity test should be carried out in accordance with the method specified in GB/T 17626.4. 5.4.5 Surge immunity test The surge immunity test should be carried out in accordance with the method specified in GB/T 17626.5. 5.4.6 Conducted disturbance immunity test induced by radio frequency field The conducted disturbance immunity test induced by the radio frequency field shall be carried out in accordance with the method specified in GB/T 17626.6. 5.5 Mechanical performance test 5.5.1 Vibration test (sinusoidal) Sweep at a rate of one octave per minute in accordance with the frequency range and amplitude specified in 4.7.1.1 of GB/T 25386.1-2021 Frequency, detect the resonance frequency of each axis, at each dangerous frequency point, in accordance with the frequency range specified in 4.7.1.2 of GB/T 25368.1-2021 Vibration resistance test is performed on the enclosure and amplitude, and the structural frequency of the control cabinet is determined through the frequency sweep test. 5.5.2 Impact test The impact endurance test should be carried out in accordance with the method specified in GB/T 2423.5.The test objects include the engine room control cabinet and its supports. 5.6 Low temperature performance test The low-temperature operation test shall be carried out in accordance with the test Ad specified in GB/T 2423.1-2008.When the test temperature is the lower limit of the working temperature and is stable After setting, the control system is energized and started to run (the product is powered on and the running time does not exceed 2h), and the continuous running time is 2h. Pass at low temperature During electrical operation, the input and output signals in the control system should be tested. At the end of the test duration, first power off the control system, and then The temperature of the test box slowly rises to within the temperature deviation range of the test standard conditions, and the temperature change in the test box should not exceed 1k/min (not more than 5min average). After the test, the control system is energized to start operation, and check whether the input and output functions of the control system are normal. 5.7 High temperature performance test The high temperature operation test shall be carried out in accordance with Test Bd specified in GB/T 2423.2-2008.When the test temperature is the upper limit of the working temperature and is stable After setting, the control system is energized to start operation, and the continuous operation time is 2h. During high-temperature power-on operation, respond to the input and output in the control system The signal is tested. At the end of the test duration, first power off the tested system, and then slowly reduce the temperature of the test chamber to the temperature of the test standard conditions. Within the range of degree deviation, the temperature change in the test box should not exceed 1k/min (not more than the average value of 5min). Check and control after the test Whether the input and output functions of the system are normal. 5.8 Humidity and heat performance test 5.8.1 Constant damp heat test The constant damp heat test should be carried out in accordance with the test method specified in GB/T 2423.3.The control system is placed in the test box without packaging and no electricity Inside, in the test chamber temperature (40 ± 2) ℃, relative humidity (93 ± 3)% conditions, the duration of 48h. The phase should be restored within 0.5h during recovery. The humidity is reduced to 73%~77%, and then the temperature is adjusted to the laboratory temperature within 0.5h. After the test, the insulation resistance should not be less than 0.5MΩ, the dielectric performance should meet the requirements specified in 4.6.2 of GB/T 25386.1-2021. 5.8.2 Alternating damp heat test The alternating damp heat test shall be carried out in accordance with the test method 1 specified in GB/T 2423.4-2008.The control system is unpackaged and placed without electricity In the test box, the temperature of the test box changes cyclically between (25±3)℃ and (55±2)℃, and the number of cycles is 2 times. After the test, the insulation resistance should be tested Not less than 0.5MΩ, the dielectric performance should meet the requirements specified in 4.6.2 of GB/T 25386.1-2021, and the measurement should be performed after the end of the recovery period. The measurement of all parameters should be completed within 0.5h after recovery. 5.9 Mold growth test According to the test method 1 in GB/T 2423.16-2008, the culture period is 28 days. The test sample is not packaged and not energized. test The test results should meet the requirements specified in 4.11 of GB/T 25386.1-2021. 5.10 Salt spray test According to the severity level 2 in GB/T 2423.18-2012, it includes. 3 spray cycles, each cycle 2h, each spray cycle After that, there is a damp and heat storage period of 20h-22h. The test sample is not packaged and not energized. The test result meets GB/T 25386.1- Requirements specified in 4.12 in 2021. 5.11 Operation monitoring function test 5.11.1 Data acquisition and processing function test When simulating key signal changes, check the correctness of the collected data through the monitoring interface to verify the data collection and processing functions of the control system. The correctness and reliability of performance. 5.11.2 Basic monitoring function test Through the monitoring interface, check whether the control system can monitor the operating status of the unit, the external environment and the grid status in real time, and trigger the machine through simulation. Group related faults, verify whether the control system protection meets the requirements of 5.2.2.2 in GB/T 25386.1-2021. 5.11.3 Human-computer interaction test View the current operating status, parameters, user permissions and status of each subsystem of the unit on the human-computer interaction interface, browse fault information and Modify parameters, etc., and check whether it meets the requirements of 5.2.2.3 in GB/T 25386.1-2021. 5.11.4 Accident and failure information recording test Simulate trigger unit accidents or failures, and check whether the control system can correctly record the corresponding information through the monitoring interface. 5.11.5 Data continuous recording function test Simulate the triggering of the unit failure, and check whether the continuously recorded data meets the requirements of 5.2.2.5 in GB/T 25386.1-2021 through the monitoring interface Claim. 5.11.6 Data statistics function test Check whether the statistical data meets the requirements of 5.2.2.6 in GB/T 25386.1-2021 through the monitoring interface. 5.11.7 Maintenance status test Check whether the maintenance function meets the requirements of 5.2.2.7 in GB/T 25386.1-2021 by flipping the maintenance switch of the control cabinet. 5.12 Coordinated control test of converter This part can use ground simulation test or field test. When using simulation test, the converter should be a real object. Under the normal working state of the control system, observe the power-on, power-off and torque demand issued by the control system by the converter through the monitoring interface Commands such as given values, as well as information such as generator speed and generator electromagnetic torque fed back to the control system, verify whether the interface and functions are correct Often, the test results should be able to meet the requirements of 5.2.3.1 in GB/T 25386.1-2021. 5.13 Coordinated control test of pitch system This part can use ground simulation test or field test. When using simulation test, the variable pitch system should be a real object. In the normal working state of the control system, observe the pitch system receiving the blade position and control issued by the control system through the monitoring interface Words and other instructions, as well as the current blade actual angle and state machine feedback to the control system, check whether the interface and function are normal, test The result should be able to meet the requirements of 5.2.3.2 in GB/T 25386.1-2021. 5.14 Start grid connection test This part can use ground simulation test or field test. When using simulation test, the converter should be a real object. When the unit is fault-free, check whether the control system has a start-up condition detection process through the monitoring interface, and when the start-up conditions are met, press Start the units separately according to the start mode in 5.2.3.3 of GB/T 25386.1-2021, and verify whether the control system can automatically coordinate and control the pitch The distance between the system and the converter completes the grid connection of the unit and enters the power generation state. The test results should meet the requirements of GB/T 25386.1-2021. The requirements of 5.2.3.3. 5.15 Variable speed control test This part can use ground simulation test or field test. After the unit is connected to the grid, when the wind speed changes between the cut-in wind speed and the rated wind speed, the control system coordinates the control of the pitch system and the converter. Through data recording and analysis, whether the wind speed-power curve or torque-speed curve is consistent with the optimal curve. 5.16 Constant power control test This part can use ground simulation test or field test. After the unit is connected to the grid, when the wind speed changes between the rated wind speed and the cut-out wind speed, the control system coordinates the control of the pitch system and the converter. Through data recording and analysis, whether the output power can be maintained within ±10% of the rated power. 5.17 Shutdown process test Field test should be used for this part. Shutdown usually includes one or more of normal shutdown, quick shutdown and emergency shutdown. When the wind speed changes between the cut-in wind speed and the rated wind speed, various types of shutdown behaviors designed by the unit are triggered, and the unit is detected and recorded The dynamic process of wind speed, generator speed, pitch angle, grid-connected point voltage, current, active power and operating state machine, the sampling period is not greater than 0.1s, the recording time meets the requirements of the corresponding technical specifications, and the test results should meet the requirements of 5.2.3.5 in GB/T 25386.1-2021. 5.18 Yaw control test 5.18.1 Manual yaw control test Operate the left yaw and right yaw function keys to execute the yaw action, and verify whether the yaw direction is consistent with the required direction. 5.18.2 Automatic yaw control test When the yaw system, anemometer and wind direction indicator are all fault-free, when the wind speed is greater than the minimum wind speed required for yaw start, manually Yaw, so that the wind deviation meets the requirements of automatic yaw and stop manual yaw. At this time, the crew should perform automatic yaw and check the automatic yaw direction and Whether the wind accuracy meets the requirements. 5.18.3 Yaw priority test In the cabin yaw state, operate the tower base yaw function key and the remote yaw function key respectively, and the crew should only perform the cabin yaw operation; In the tower bottom yaw state, operate the remote yaw function key, and the crew should only perform the tower bottom yaw operation; in the tower bottom yaw state, operate the cabin yaw power Yes, the crew should only perform cabin yaw operations. During the automatic yaw process, operate the cabin yaw function key, the tower base yaw function key or the far The control system should stop the automatic yaw action and execute the corresponding manual yaw action. 5.19 Unmooring control test This part can use ground simulation test or field test. When the yaw is fault-free and the wind speed is greater than the minimum wind speed required for yaw start, manual yaw is used to make the twisting angle greater than the automatic untwisting angle Stop manual yaw and switch to automatic yaw state. At this time, the crew should perform automatic unmowing and analyze whether the twisting angle is correct after unmowing is completed. Combined unit design requirements. 5.20 Offshore crew control test 5.20.1 Redundant function test According to the design description of the unit, in the power generation operation state of the unit, the module that declares the redundancy function for the unit, artificially triggers the redundancy Function, observe whether the performance of the unit conforms to the design specification, whether the redundant function can be automatically activated, and whether the redundant equipment abnormal warning message is reported. 5.20.2 Remote fault diagnosis test According to the design description of the unit, when the unit is in the power generation operation state, the number of targeted faults is artificially created through the remote system observation. According to whether it can meet the requirements of accurately locating the fault location, determining the fault status of the unit, and determining the feasibility of resetting. 5.20.3 Remote control function and permission test According to the design i......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 25386.2-2021_English be delivered?Answer: Upon your order, we will start to translate GB/T 25386.2-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 25386.2-2021_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 25386.2-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 25386.2-2021?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 25386.2-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |