GB/T 23660-2009 English PDFUS$369.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 23660-2009: Building structure crack split-stopping tape Status: Valid
Basic dataStandard ID: GB/T 23660-2009 (GB/T23660-2009)Description (Translated English): Building structure crack split-stopping tape Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G47 Classification of International Standard: 83.140.01 Word Count Estimation: 16,183 Date of Issue: 2009-04-24 Date of Implementation: 2009-12-01 Regulation (derived from): PRC National Standard Approval Announcement 2009 No.6 (Total No.146) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the building structural cracks crack band ended (hereinafter referred to as the crack band-stop) the terms and definitions, requirements, test methods, inspection rules, signs, packaging, storage and transport. This standard applies to the elastic modulus (200 to 300) MPa synthetic polymer materials for the core, the core surface recombination hot tangential arrangement of acid forming method of synthetic fiber ribbon can be wound composite film. Between the main structure of the building is mainly used for sewing all kinds of masonry and plaster frame shear corresponding structures such as, due to the construction of the main structure corresponding to prevent deformation or cracking joints caused cracks in plaster parts. Application Diagram See Appendix A. GB/T 23660-2009: Building structure crack split-stopping tape---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Building structure crack split-stopping tape ICS 83.140.01 G47 National Standards of People's Republic of China Structural cracks with crack arrest Posted 2009-04-24 2009-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThe standard of Appendices B and C are normative appendices, Appendix A is an information appendix. The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Rubber and rubber products Standardization Technical Committee rubber sundries Club (SAC/TC35/SC7) centralized. This standard was drafted. Kazakhstan Tech Suileng two plastic Limited. The main drafters of this standard. He Shaolan, Tianchun Feng, Li Po double. Structural cracks with crack arrest1 ScopeThis standard specifies the terms and definitions structural cracks with crack arrest (hereinafter referred to as crack arrest belt), requirements, test methods, inspection rules, marking Chi, packaging, storage and transportation. This standard applies to the elastic modulus (200 ~ 300) MPa synthetic polymer material as the core, the core surface of the composite heat tangential arrangement Rolling method of forming acid synthetic fiber ribbon can be wound composite sheet. Mainly used in construction of the main structure of various types of frame-wall masonry structures such as joints and Correspondence between the wiping surface and prevents the corresponding structural joints due to the construction of the main deformation or rupture caused by wiping the surface portion cracks. Application diagram Appendix A.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 11547-2008 plastic resistant to liquid chemical reagent performance measurement3 Terms and DefinitionsThe following terms and definitions apply to this standard. 3.1 Elastic modulus (200 to 300) MPa synthetic polymer materials for the core layer, the surface of the composite core disposed tangential molding method of hot rolling resistance Acid synthetic fibers, used to prevent construction of the main structures of various types of frame-wall masonry structures such as deformation or split seams corresponding to wipe the surface layer caused by generation Cracks can strip winding sheet. 3.2 Structural cracks with crack arrest binding strength of the core layer and the surface layer, with N/cm representation. 3.3 Structural cracks with crack arrest and engineering to withstand shear adhesive body size, expressed in MPa.4 Requirements4.1 Dimensions and tolerances Dimensions and tolerances are shown in Table 1. Table 1 Dimensions and tolerances Item Width/mm thickness/mm Length/(m/disc) Size 190,230,285,385 0.60 50 or more Tolerance ± 5mm ± 10% allowed negative Note. Special specifications agreed upon by both parties. ...... |