GB/T 23199-2008 English PDFUS$399.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 23199-2008: Determination of rare earth elements in tea by inductively coupled plasma emission spectrometry and inductively coupled plasma mass spectrometry Status: Obsolete
Basic dataStandard ID: GB/T 23199-2008 (GB/T23199-2008)Description (Translated English): Determination of rare earth elements in tea by inductively coupled plasma emission spectrometry and inductively coupled plasma mass spectrometry Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: X55 Classification of International Standard: 67.140.10 Word Count Estimation: 10,140 Date of Issue: 2008-12-31 Date of Implementation: 2009-06-01 Regulation (derived from): National Standard Approval Announcement 2008 No.27 (Total No.140) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma atomic emission spectrometry (ICP-AES)-Determination of tea scandium (Sc), yttrium (Y), lanthanum (La), cerium (Ce), praseodymium (Pr), neodymium (Nd), samarium (Sm), europium (Eu), gadolinium (Gd), terbium (Tb), dysprosium (Dy), holmium (Ho), erbium (Er), thulium (Tm), ytterbium (Yb), lutetium (Lu) and other 16 kinds of rare earth elements (hereinafter referred to as 16 kinds of rare earth elements) method. This standard applies to the determination of rare earth elements in tea 16 kinds of. Inductively coupled plasma mass spectrometry detection limit: element scandium, yttrium, cerium, praseodymium, neodymium, samarium europium lanthanide detection limit/(��g/kg) 0. 5 0. 4 0. 09 0. 1 0. 07 0. 09 0. 2 0. 05 gadolinium, terbium, dysprosium, holmium, erbium element thulium, ytterbium, lutetium detection limit/(��g/kg) 0. 1 0. 3 0. 2 0. 05 0. 06 0. 05 0. 07 0. 05 inductively coupled plasma atomic emission spectrometry detection limit: Elements of scandium, yttrium, cerium, praseodymium, neodymium, samarium europium lanthanide detection limit/(��g/kg) 0. 4 2 11 15 16 16 9 7 elements gadolinium, terbium, dysprosium, holmium, erbium, thulium, ytterbium, lutetium detection limit/(��g/kg) 5 8 5 3 14 4 0. 6 0. 9. GB/T 23199-2008: Determination of rare earth elements in tea by inductively coupled plasma emission spectrometry and inductively coupled plasma mass spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Determination of rare earth elements in tea by inductively coupled plasma emission spectrometry and inductively coupled plasma mass spectrometry ICS 67.140.10 X55 National Standards of People's Republic of China Determination of rare earth elements in tea Inductively coupled plasma atomic emission spectrometry and Inductively Coupled Plasma Mass Spectrometry Posted 2008-12-31 2009-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThe Standard Appendix A, Appendix B, Appendix C are informative appendices. This standard was proposed by the National Food Quality Supervision, Inspection and Safety Center. This standard by the National Standardization Technical Committee of tea. This standard was drafted. the National Food Quality Safety Supervision and Inspection Center, the National Tea Quality Supervision and Inspection Center. The main drafters of this standard. everywhere, Yang Yanli, Zhou Weilong, non versed week, Chen, Xu Ling. Determination of rare earth elements in tea Inductively coupled plasma atomic emission spectrometry and Inductively Coupled Plasma Mass Spectrometry1 ScopeThis standard specifies the inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma atomic emission spectrometry (ICP-AES) measured Given tea scandium (Sc), yttrium (Y), lanthanum (La), cerium (Ce), praseodymium (Pr), neodymium (Nd), samarium (Sm), europium (Eu), gadolinium (Gd), terbium ( tb), dysprosium (Dy), Holmium (Ho), erbium (Er), thulium (Tm), ytterbium (Yb), lutetium (Lu) and other 16 kinds of rare earth elements (hereinafter referred to as 16 kinds of rare earth elements) method. This standard applies to the determination of 16 kinds of tea rare earths. Inductively Coupled Plasma Mass Spectrometry detection limit. Element yttrium scandium lanthanum, cerium, praseodymium, neodymium, samarium europium The detection limit/(μg/kg) 0.5 0.4 0.09 0.1 0.07 0.09 0.2 0.05 Element gadolinium, terbium, dysprosium, holmium, erbium, thulium, ytterbium, lutetium The detection limit/(μg/kg) 0.1 0.3 0.2 0.05 0.06 0.05 0.07 0.05 Inductively coupled plasma atomic emission spectrometry detection limit. Element yttrium scandium lanthanum, cerium, praseodymium, neodymium, samarium europium The detection limit of/(μg/kg) 0.4 2 11 15 16 16 9 7 Element gadolinium, terbium, dysprosium, holmium, erbium, thulium, ytterbium, lutetium The detection limit of/(μg/kg) 5 8 5 3 14 4 0.6 0.92 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 6682-2008 analytical laboratory use specifications and test methods (ISO 3696. 1987, MOD) GB/T 8302 sampling tea GB/T 8303-2002 tea milled sample preparation and determination of dry matter content (eqv ISO 1572. 1980) The first Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Principle 3 The samples were acid digestion solution with deionized water to dissolve, set the volume to volume. The sample solution was introduced into an inductively coupled plasma mass spectrometer (ICP-MS), a standard sample of each element corresponding to the mass of the premises response signal contrast, the content of each element is obtained. Were measured 16 kinds of rare earth elements in a given content, calculate the total amount.4 ReagentsUnless otherwise indicated, the reagents used in the analysis are excellent pure water to GB/T 6682-2008 specified level of water. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 23199-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 23199-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 23199-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 23199-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |