Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 22694-2008 English PDF

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 22694-2008RFQ ASK 6 days Fixed residual current protective socket-outlets without integral overcurrent protection for household and similar uses (FRCS) Obsolete

Similar standards

GB/T 16935.3   GB/T 18802.31   GB/Z 16935.2   GB/T 11918.6   GB/T 15934   GB/T 14048.11   

Basic data

Standard ID: GB/T 22694-2008 (GB/T22694-2008)
Description (Translated English): Fixed residual current protective socket-outlets without integral overcurrent protection for household and similar uses (FRCS)
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K30
Classification of International Standard: 29.120.30
Word Count Estimation: 37,382
Date of Issue: 2008-12-31
Date of Implementation: 2009-11-01
Regulation (derived from): Announcement of Newly Approved National Standards No. 23 of 2008 (No. 136 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the household and similar fixed residual current protection socket (hereinafter referred FRCS) requirements. This standard applies without over -current protection, AC 50Hz or 60Hz, rated voltage to ground does not exceed AC 250V, rated current not exceeding 16A single- phase circuit FRCS. FRCS also be used as additional shock protection failure supplementary protection measures. FRCS within the scope of this standard applies to residual current can be executed simultaneously detect the residual current value is compared with a reference value and when the residual current exceeds this value, disconnect the circuit to be protected features such as fixed installations. FRCS within the scope of this standard in addition to a conventional power socket of the basic functions, but also has a ground fault protection and other functions, the current setting is not self-regulation can not be modified. FRCS rated residual operating current not exceeding 0. 03A, fixed socket should meet the relevant national standards. Technical requirements of this standard apply to 7. 1 specified environmental conditions. In more severe ambient conditions using FRCS may need to supplement the technical conditions. FRCS contains batteries not included within the scope of this standard. This standard does not apply to the power side of the fault has detected an additional function, and failure in the power supply circuit to prevent its closure FRCS.

GB/T 22694-2008: Fixed residual current protective socket-outlets without integral overcurrent protection for household and similar uses (FRCS)


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Fixed residual current protective socket-outlets without integral overcurrent protection for household and similar uses (FRCS) ICS 29.120.30 K30 National Standards of People's Republic of China Household and similar purposes without overcurrent protection Fixed residual current protection socket (FRCS) Posted 2008-12-31 2009-11-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 Category 6 5 FRCS features 7 6 logos and other product information 9 7 and 10 of the standard operating conditions Installation 8 Structure and operating requirements 10 9 Test 16 Test procedure Appendix A (normative) to verify compliance with this standard and the number of samples submitted 26 Appendix B (normative) Routine tests 30 Annex C (normative) determining clearances and creepage distances 31 Annex D (normative) FRCS verify compliance with electromagnetic compatibility (EMC) test technical requirements, additional test procedures and test again Quantity List 33

Foreword

The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Electric annex Standardization Technical Committee (SAC/TC67) centralized. This standard was drafted. Zhejiang Chint Building Appliance Co., Ltd., Hangzhou Hongyan Electric Co., Ltd., Suzhou Road think the United States Electric Co., Ltd., TCL- Legrand low-voltage electrical (Wuxi) Co., Ltd., Shanghai Hyde Electronics Manufacturing Co., Ltd., China Electric Apparatus Research Institute. The main drafters of this standard. Chen, single toward blue, Chuang Yu, Jun Kong, TURAL Chen positive, Zhu Zhenqing, Li Lixin, Luohuai Ping, Luzhen You, Cao canal. Household and similar purposes without overcurrent protection Fixed residual current protection socket (FRCS)

1 Scope

This standard specifies the household and similar fixed residual current protection socket (hereinafter referred FRCS) requirements. This standard applies Without overcurrent protection for AC 50Hz or 60Hz, ground rated voltage not exceeding AC 250V, rated current not exceeding 16A single FRCS phase circuit. FRCS also be used as supplementary electric shock protection other protective measures at failure. FRCS within the scope of this standard applies to residual current detection can be performed simultaneously, the residual current value is compared with a reference value and when Fixed installations when the residual current exceeds this value, disconnect the protected circuit functions. FRCS within the scope of this standard in addition to the basic functions of a traditional power outlet outside, and a ground fault protection and other functions, tuning power Stream can not adjust itself, not can be modified. FRCS rated residual operating current not exceeding 0.03A, fixed socket should comply with the relevant national standards. This standard applies to the technical requirements of the environmental conditions specified in 7.1. Under more severe environmental conditions may need to add the FRCS Technical conditions. FRCS contain batteries not included within the scope of this standard. This standard does not apply to the additional function which detects the power supply side of the fault, and to prevent its closure FRCS when the power supply circuit failure. Note. Consistent with the general requirements FRCS requirements of GB 16916.1. FRCS mainly operated by non-professionals and is designed to not require maintenance.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 1002 Household and similar single-phase plugs and socket type, basic parameters and dimensions GB 2099.1-2008 plug socket for household and similar purposes - Part 1. General requirements (IEC 60884-1.2006, MOD) GB/T 4207-2003 solid insulating materials under moist conditions index tracking of the measuring method and the proof tracking index compared (IEC 60112. 1979, IDT) GB 4208-2008 housing protection (IP Code) (IDTIEC 60529.2001) GB/T 5169.10-2006 Fire hazard testing for electric and electronic products - Part 10. Glowing/hot wire based test methods for burning Hot wire apparatus and common test procedure (IEC 60695-2-1-10.2000, IDT) (RCCB) Part 1 GB 16916.1-2003 household and similar uses overcurrent protection for residual current operated circuit breaker Score. General rules (IEC 61008-1.1996, MOD) GB/T 16935.3-2005 within low-voltage systems Insulation coordination for equipment - Part 3 use coatings, canned or molding for antifouling Protection (IEC 60664-3.2003, IDT) GB 18499-2008 household and residual current device similar purposes (RCD) Electromagnetic compatibility (IEC 61543.1995, IDT) Portable residual current device (PRCD) GB 20044-2005 electrical accessories for household and similar purposes without overcurrent protection (IEC 61540.1997, MOD)
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 22694-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 22694-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 22694-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 22694-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.