GB/T 20441.5-2017 English PDFUS$319.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 20441.5-2017: Electroacoustics -- Measurement microphones -- Part 5: Methods for pressure calibration of working standard microphones by comparison Status: Valid
Basic dataStandard ID: GB/T 20441.5-2017 (GB/T20441.5-2017)Description (Translated English): Electroacoustics -- Measurement microphones -- Part 5: Methods for pressure calibration of working standard microphones by comparison Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: A59 Word Count Estimation: 16,145 Date of Issue: 2017-09-07 Date of Implementation: 2018-04-01 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GB/T 20441.5-2017: Electroacoustics -- Measurement microphones -- Part 5: Methods for pressure calibration of working standard microphones by comparison---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Electroacoustics - Measurement microphones - Part 5. Methods for pressure calibration of working standard microphones by comparison ICS 17.140.50 A59 National Standards of People's Republic of China Electro-acoustic measurement microphone Part 5. Working standard microphone sound pressure Calibrated comparison method Part 5.Methodsforpressurecalibrationofworking (IEC 61094-5.2001, IDT) 2017-09-07 Posted 2018-04-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Reference environmental conditions 2 5 Comparison of sound pressure calibration principle 2 5.1 Principle 2 5.2 Microphone output voltage measurement 3 6 factors affecting the sensitivity of sound pressure 3 6.1 Overview 3 6.2 microphone pressure balanced leakage 3 6.3 Polarization voltage 3 6.4 Ground Shield Reference Structure 3 6.5 Diaphragm pressure distribution 3 6.6 Relationship with environmental conditions 4 6.7 Confirm 4 7 Calibration uncertainty component 4 7.1 Overview 4 7.2 Reference Microphone Sensitivity 4 7.3 Microphone output measurement 4 7.4 measured microphone and reference microphone at the sound pressure difference 4 7.5 Sound pressure sensitivity level of uncertainty 4 Appendix A (Informative) Examples of Simultaneous Exciter Couplers and Mounting Devices Appendix B (Informative) Examples of Incentive Couplers Appendix C (informative) without the insertion voltage method to determine the opening microphone sensitivity measurement 10 Appendix D (Informative) Typical Uncertainty Analysis 11 Reference 13 ForewordGB/T 20441 "measuring microphone" is divided into 8 parts. --- Part 1. Laboratory standard microphone specifications; --- Part 2. Reciprocal techniques for laboratory-standard microphones sound pressure calibration of the primary method; --- Part 3. Reciprocal techniques for the laboratory standard microphone free field calibration of the primary method; --- Part 4. Working standard microphone specifications; --- Part 5. Working standard microphone sound pressure calibration comparison method; --- Part 6. Electrostatic exciter to measure the frequency response; --- Part 7. Laboratory standard microphone free field sensitivity and sound pressure sensitivity of the difference between; --- Part 8. Working standard microphone free field calibration comparison method. This section GB/T 20441 Part 5. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the translation method identical with IEC 61094-5.2001 "electroacoustic measurement microphone Part 5. Working standard microphone Sound pressure calibration comparison method. " The documents of our country that are consistent with the corresponding international documents that are normative references in this section are as follows. --- GB/T 20441.1-2010 Electroacoustic measuring microphones Part 1. Laboratory standard microphone specifications (IEC 61094- 1.2000, IDT) --- GB/T 20441.4-2006 Measuring microphones Part 4. Working standard microphone specifications (IEC 61094-4.1995, IDT) Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents. This part is proposed by the Ministry of Industry and Information Technology of the People's Republic of China. This part of the National Electroacoustic Standardization Technical Committee (SAC/TC23) centralized. The main drafting units in this section. China Institute of Metrology, Hengyang Hengyi Electric Co., Ltd., China Electronics Technology Group Corporation third graduate School. The main drafters of this section. Xu Huan, Zhang Mei E, Liu Xiang Heng, Weng Tailai, Chen Jianlin. Electro-acoustic measurement microphone Part 5. Working standard microphone sound pressure Calibrated comparison method1 ScopeGB/T 20441 provisions of this part of the laboratory has been calibrated according to IEC 61094-2.1992 standard microphones or have been according to the Department Sub-calibrated working standard microphones are compared to determine the sound pressure sensitivity method. This section applies to meet the requirements of IEC 61094-4 and protect the hood can be removed working standard microphones and meet IEC 61094-1 Seeking laboratory standard microphone. The comparison method based on the principle described in IEC 61094-2.1992 is also feasible, but is beyond the scope of this section.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. IEC 61094-1 Measurement Microphone Part 1. Laboratory Standard Microphone Specification (Measurement Microphones- Part 1.Specifications for laboratory standard microrophones) IEC 61094-2.1992 Measuring microphones - Part 2. Original sound pressure calibration of laboratory standard microphones using reciprocity techniques Level method (Measurementmicrophones-Part 2.Primarymethodforpressurecalibrationoflaboratory standardmicrophonesbythereciprocitytechnique) IEC 61094-4 Measurement microphones Part 4. Working standard microphone specifications (Measurementmicrophones-Part 4. Specificationsforworkingstandardmicrophones) ISO /IEC GUIDEEXPRESS.1995 Measurement Uncertainty Guide [Guidetotheexpressionofuncer- taintyinmeasurement (GUM)]3 Terms and definitionsIEC 61094-1 defines the following terms and definitions apply to this document. 3.1 Reference microphone referencemicrophone Sound pressure sensitivity has been determined in advance laboratory standard microphone or working standard microphone. 3.2 Measured microphone testmicrophone A lab standard microphone or a working standard microphone that is calibrated by comparison with a reference microphone. 3.3 Monitor microphone monitormicrophone Microphone for measuring changes in sound pressure in the coupler. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 20441.5-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 20441.5-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 20441.5-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 20441.5-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |