GB/T 19216.12-2008: Tests for electric or optical fibre cables under fire conditions -- Circuit integrity -- Part 12: Apparatus -- Fire with shock at a temperature of at least 830 Celsius
Status: Obsolete
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 19216.12-2008559 Add to Cart 3 days Tests for electric or optical fibre cables under fire conditions -- Circuit integrity -- Part 12: Apparatus -- Fire with shock at a temperature of at least 830 Celsius Obsolete

Similar standards

GB/T 12706.3   GB/T 12706.4   GB/T 19666   GB/T 29631   GB/T 19216.2   GB/T 19216.3   

Basic data

Standard ID: GB/T 19216.12-2008 (GB/T19216.12-2008)
Description (Translated English): Tests for electric or optical fibre cables under fire conditions -- Circuit integrity -- Part 12: Apparatus -- Fire with shock at a temperature of at least 830 Celsius
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K13
Classification of International Standard: 29.060.20
Word Count Estimation: 14,143
Date of Issue: 2008-12-31
Date of Implementation: 2009-11-01
Adopted Standard: IEC 60331-12-2002, IDT
Regulation (derived from): Announcement of Newly Approved National Standards No. 23 of 2008 (No. 136 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard provides for controlled heat output nominal temperature is 850��C flame for the fire and mechanical shock test conditions required to maintain circuit integrity test cable test device used. Appendix A provides a test with a blowtorch and control system authentication method.

GB/T 19216.12-2008: Tests for electric or optical fibre cables under fire conditions -- Circuit integrity -- Part 12: Apparatus -- Fire with shock at a temperature of at least 830 Celsius


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Tests for electric or optical fibre cables under fire conditions Circuit integrity Part 12.. Apparatus Fire with shock at a temperature of at least 830 Celsius ICS 29.060.20 K13 National Standards of People's Republic of China GB/T 19216.12-2008/IEC 60331-12.2002 Under fire conditions or fiber optic cable lines Integrity testing - Part 12. Apparatus --- Flame temperature of not lower than 830 ℃ Impact is applied for fights (IEC 60331-12.2002, Testsforelectriccablesunderfireconditions- Circuitintegrity-Part 12. Apparatus- Firewithshockatatemperatureofatleast830 ℃, IDT) Posted 2008-12-31 2009-11-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions Test conditions 4 1 5 Test apparatus 1 Appendix A (normative) heat source verification program 8 Reference 9 GB/T 19216.12-2008/IEC 60331-12.2002

Foreword

GB/T 19216 "in electric cables under fire conditions - Circuit integrity" is divided into six sections. --- Part 11. Test equipment --- flame temperature not lower than 750 ℃ \u200b\u200bseparately for the fire; Applying an impact test apparatus --- flame temperature of not lower than 830 ℃ for fights;. --- Part 12 --- Part 21. Procedures and requirements --- rated voltage 0.6/1.0kV and below cable; --- Part 23. Procedures and requirements --- data cable; --- Part 25. Procedures and requirements --- fiber optic cable; --- Part 31. for fire with shock - Test procedure and requirements --- rated voltage 0.6/1kV and below cable. This section GB/T Part of 1,219,216. This section identical with IEC 60331-12.2002 "under fire conditions - Circuit integrity - Part 12 cables. Test installed Applying an impact "means --- flame temperature not lower than 830 ℃ for the fights. For ease of use, this section made the following editorial changes. --- This part name is amended as. "In the electric cables under fire conditions - Circuit integrity - Part 12. Apparatus --- Applying an impact flame temperature not lower than 830 ℃ for the fights "; --- This part corresponds to the name, the English name changed to. "Testsforelectricoropticalfibrecablesunderfire conditions-Circuitintegrity-Part 12. Apparatus-Firewithshockatatemperatureofat least830 ℃ "; --- Remove the IEC 60331-12.2002 Foreword and Introduction; --- With a decimal point "." Instead of a comma as the decimal point "." This section of Appendix A normative appendix. This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee Wire and Cable (SAC/TC213) centralized. This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute. Participated in the drafting of this section. Wuxi Jiangnan Cable Co., Ltd., Shanghai-Wuxi City Electric Wire & Cable Co., Ltd., Jiangsu has a new remote cable Limited, Jinlong Yu Group Co., Ltd., Shanghai Shenghua Cable (Group) Co., Ltd., Sichuan Star Cable Co., Ltd. The main drafters of this section. Gong Guoxiang, Xia Yafang, money Xiaojuan, Xueyuan Hong, Lu technology only, Jinhai Wen, Wu Sheng industry. This section first release. GB/T 19216.12-2008/IEC 60331-12.2002 Under fire conditions or fiber optic cable lines Integrity testing - Part 12. Apparatus --- Flame temperature of not lower than 830 ℃ Impact is applied for fights

1 Scope

GB/T 19216 provisions of this section for the fire and mechanical shock testing conditions for controlled thermonuclear flame output at a nominal temperature of 850 ℃ , The test equipment required to maintain the integrity of the test cable lines used. Appendix A provides a test with a blowtorch and control system authentication method.

2 Normative references

The following documents contain provisions which, through reference GB/T 19216 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 19216.11-2003 in electric cables under fire conditions - Circuit integrity - Part 11. Apparatus --- Flame temperature not lower than 750 ℃ \u200b\u200bfor a separate fire (IEC 60331-11.1999, IDT) GB/T 16839.1-1997 Thermocouples - Part 1. indexing table (idt IEC 60584-1.1995) IEC Guide 104.1997 Safety Publications application development and basic safety publications and similar security publications

3 Terms and Definitions

The following terms and definitions apply to this section. 3.1 When under fire and prescribed burning time, it can continue to run in the state the ability to specify.

4 Test conditions

4.1 Test Environment The test shall be in a suitable housing having at least 20m3 in the conduct of the cabinet has provided any removal of harmful gases produced by combustion Shi, and to maintain adequate ventilation during the test flame. But should not use forced ventilation. Note 1. Examples of suitable housing, such as GB/T 17651.1 specified in the combustion chamber. At the beginning of each test, the test box and the device should be kept between 10 ℃ ~ 40 ℃. In the cable test and verification process, cabinets and barrier ventilation conditions should be the same. Note 2. barrier, such as GB/T 17651.1 specified baffles can be put in place to protect the torch, so that air does not affect the geometry of the flame. Note 3. This part of the test may use hazardous voltage and temperature, should be appropriate protective measures to prevent possible shock, burning, fire and explosion And dangerous, and prevent any harmful gases that may arise.

5 test device

5.1 Test apparatus consisting of Test equipment should have the following components. GB/T 19216.12-2008/IEC 60331-12.2002
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 19216.12-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 19216.12-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 19216.12-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 19216.12-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.