GB/T 18014-2008 English PDFUS$299.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 18014-2008: PVC insulated wire for ignition of electric detonators Status: Valid GB/T 18014: Historical versions
Basic dataStandard ID: GB/T 18014-2008 (GB/T18014-2008)Description (Translated English): PVC insulated wire for ignition of electric detonators Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K13 Classification of International Standard: 29.060.20 Word Count Estimation: 13,140 Date of Issue: 2008-06-18 Date of Implementation: 2009-03-01 Older Standard (superseded by this standard): GB 18014-1999 Regulation (derived from): Announcement of Newly Approved National Standards No. 10 of 2008 (total 123) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the electrical blasting detonators with PVC insulated wire (hereinafter referred to as detonating cords) product classification, code, models, technical requirements, test methods and inspection rules, packaging, labeling and storage. This standard applies to electrical detonators and galvanized steel core with a copper core PVC insulated wire. GB/T 18014-2008: PVC insulated wire for ignition of electric detonators---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.PVC insulated wire for ignition of electric detonators ICS 29.060.20 K13 National Standards of People's Republic of China Replacing GB 18014-1999 Electric detonators PVC insulated wire Posted 2008-06-18 2009-03-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ 1 Scope 1 2 Normative references 1 3 Definitions 1 4 classification, code, model and product representation 1 5 2 Technical Requirements 6 Test Method 3 7 Inspection rules 5 8 packaging, labeling and storage of 5 Appendix A (normative) galvanized steel core conductors 7ForewordThis standard replaces GB 18014-1999 "electrical detonators PVC insulated wire." This standard compared with GB 18014-1999 main changes are as follows. --- GB 18014-1999 canceled in 6.1.1,6.1.2,6.1.3 article, the contents of which are incorporated in Chapter 3 of this standard; --- Modify finished detonation pressure test described in the text line (before version 4.4.3, this version 5.4.3); --- The GB/T 18014-1999 6.3,6.4,6.5 as category in this standard 6.4; --- Increasing the looped wire diameter tolerance requirements (edition 8); --- "Quality" to "quality (weight)" (before version 7.1, this version 8); --- Clearly Appendix A normative appendix (the previous version to Appendix A, this edition Appendix A); --- Increasing the "look and feel" requirements (Excerpts Table A.2); --- Increased reading and related content measurements (Excerpts A.2.1). Appendix A of this standard is a normative appendix. The standard proposed by China Electrical Equipment Industrial Association. This standard by the national wire and cable Standardization Technical Committee (SAC/TC213) centralized. Drafting of this standard. Shanghai Electric Cable Research Institute. Participated in the drafting of this standard. Fushun Branch of Coal Science Research Institute, Shenyang twenty-three factory, Wenzhou Zhenhua Electronics Co., Ltd., Hangzhou, Wei Xin Electronics Co., Ltd. Chengdu Xin cattle cable. The main drafters of this standard. Lu Yanhong, para. , Liu Shan, Yang Feng, Li Xiaodong, Wei Ying, Zhang Xian Ling. This standard replaces the previous editions of the standard. --- GB/T 18014-1999. Electric detonators PVC insulated wire1 ScopeThis standard specifies the electrical blasting detonators PVC insulated wire (hereinafter referred to as detonating cords) product classification, code, type No, technical requirements, test methods and inspection rules, packaging, labeling and storage. This standard applies to electrical detonators and galvanized steel core with a copper core PVC insulated wire.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 2951.11-2008 cable insulation and sheathing materials test methods - Part 11. General test method --- thickness Dimensions and measurement --- mechanical tests (IEC 60811-1-1.2001, IDT) GB/T 3048.4-2007 electrical wire and cable performance test methods - Part 4. Conductor DC resistance test GB/T 3048.8-2007 electrical wire and cable performance test methods - Part 8. AC voltage test (IEC 60060-1. 1989, NEQ) GB/T 3048.9-2007 electrical wire and cable performance test methods - Part 9. spark test of insulated cores GB/T 3953-1983 electrician round copper wire GB/T 4909.2-1985 Test methods for bare wires sizing (neqIEC 251. 1978) GB/T 4909.3-1985 Test methods for bare wires tensile test (neqIEC 207. 1966) GB/T 8815-2002 with a soft PVC wire and cable (IEC 60227-1.1993, NEQ)3 DefinitionsThe following definitions apply to this standard. 3.1 By the manufacturer in the manufacturing of all finished detonating cord length of detonating cord to verify the integrity of the test. 3.2 According to the frequency specified by the manufacturer in the finished detonating cords on the sample or on specimens taken from the finished detonating cords carried out to verify the finished primer Explosion line to meet the requirements of the test. 3.3 Before rolling out this standard provides a model of detonating cord, in order to verify satisfactory performance characteristics when consistent with its intended use The tests carried out. After the completion of the type examination, generally we do not need to repeat the test, but the performance characteristics of detonating cords affecting raw materials, When there is a change design and manufacturing processes need to repeat the test. 4 classification, code, model and product representation 4.1 Classification 4.1.1 Material and galvanized steel core and copper core conductors into a conductor. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 18014-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 18014-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 18014-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18014-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 18014-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18014-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |