GB/T 16841-2008 English PDFUS$834.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 16841-2008: Guide for dosimetry in an electron beam facility for radiation processing at energies between 300 keV and 25 MeV Status: Valid GB/T 16841: Historical versions
Basic dataStandard ID: GB/T 16841-2008 (GB/T16841-2008)Description (Translated English): Guide for dosimetry in an electron beam facility for radiation processing at energies between 300 keV and 25 MeV Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: A58 Classification of International Standard: 17.240 Word Count Estimation: 42,433 Date of Issue: 2008-09-19 Date of Implementation: 2009-08-01 Older Standard (superseded by this standard): GB/T 16841-1997 Adopted Standard: ISOASTM 51649-2005, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the electron beam radiation processing in order to ensure all products to produce the desired effects of radiation received by the dose required, confirm the installation, operation confirmation, performance qualification (IQ, OQ and PQ) and daily doses that are involved in processing of measurement procedures, as well as the possible impact of these processes and products in the absorbed dose to monitor other programs. GB/T 16841-2008: Guide for dosimetry in an electron beam facility for radiation processing at energies between 300 keV and 25 MeV---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Guide for dosimetry in an electron beam facility for radiation processing at energies between 300 keV and 25 MeV ICS 17.240 A58 National Standards of People's Republic of China GB/T 16841-2008/ISO /ASTM51649.2005 Replacing GB/T 16841-1997 Processing apparatus dosimetry guidelines (ISO /ASTM51649.2005, Standardpracticefor processingatenergiesbetween300keVand25MeV, IDT) Posted 2009-08-01 2008-09-19 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4. Significance and Use 7 5 Characteristics of the radiation source 7 The main types of irradiation apparatus 6 8 7 dosimetry system 8 8 9 processing parameters 9 9 Installation Qualification 10 OQ 11 11 12 Performance Qualification Daily production and processing 13 12 13 14 Measurement Uncertainty 14 Certificate 14 Keywords 15 15 Appendix A (informative) electron beam depth dose distribution, temperature and radiation material processing yield during processing 16 Annex B (informative) beam width and the beam width dosimetry unevenness 25 Annex C (informative) electron beam energy is determined by the depth dose distribution 26 Annex D (informative) energy is greater than 300keV electron accelerator features 33 References 35 GB/T 16841-2008/ISO /ASTM51649.2005ForewordThis standard is identical with ISO /ASTM51649.2005 "energy of 300keV ~ 25MeV electron beam radiation processing dosimetry Guidelines "(in English). For ease of use, this standard made the following editorial changes. a) prepared in accordance with Chinese customary for some format has been modified. b) for ISO /ASTM51649. other international standards cited in 2005 have been adopted as the equivalent of the standard, this section with References of these national standards or industry standards corresponding to international standards in place, the rest not equivalent to the standards of China International standards in this standard are a direct reference. c) the original number of international standards in Appendix A1, A2, A3, A4 to Appendix A, Appendix B, Appendix C, Appendix D. This standard replaces GB/T 16841-1997 "energy of 300keV ~ 25MeV electron beam radiation processing dosimetry guidelines." this Standard and GB/T 16841-1997 main changes are as follows. --- Redefined the standards applicable to the "scope" (1997 version of Chapter 1; Chapter 2 of this edition); --- An increase of some terminology, and the original part of the standard terminology redefined (Excerpts Chapter 3); --- Added "dosimeter calibration system" article and specific requirements (see Excerpts 7.3.1,7.3.2,7.3.3, Note 4); --- With "Confirm Installation", "Operation Qualification", "performance verification" and "daily production process," replaced "means to confirm," "confirmation process" and "Daily production and processing" (see the 1997 version of Chapter 7, Chapter 8, Chapter 9; edition, Chapter 9, Chapter 10, Chapter 11, Section 12 chapter); --- Added "Processing Parameters" chapter content (see Chapter 8 edition); --- Increasing the uncertainty of classification standards and evaluation criteria (see Chapter 13); --- Refine the initial energy of the electron beam is determined by the depth dose distribution methods methods and conditions (see Appendix A Excerpts); --- Re-described "microwave power accelerator" and "RF Power Accelerator" performance characteristics (see Appendix D of this edition and D.1.2 D. 1.3). The Standard Appendix A, Appendix B, Appendix C and Appendix D is an informative annex. 2002, IDT) GB/T 16639 using standard methods -EPR alanine dosimetry system (GB/T 16639-2008, ISO /ASTM 51607.2004, IDT) Selection and calibration of the guide GB/T 16640 dosimetry systems for radiation processing is (GB/T 16640-2008, ISO /ASTM 51261.2002, IDT) GB 18280 Sterilization of health care products requires validation and routine control of radiation sterilization (GB 18280-2000, ISO 11137. 1995, IDT) ISO /ASTM51205 using cerium sulfate - cerous dosimetry system Practice Practice ISO /ASTM51275 color film using radiation dosimetry systems ISO /ASTM51276 using polymethylmethacrylate dosimetry system Practice ISO /ASTM51401 use dichromate dosimetry system Practice ISO /ASTM51431 electron beam and X-ray (bremsstrahlung) facility for food processing dosimetry practice ISO /ASTM51538 chlorobenzene - Practice ethanol dose measurement system ISO /ASTM51539 radiation-sensitive labels indicating Guide GB/T 16841-2008/ISO /ASTM51649.2005 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 16841-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 16841-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 16841-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 16841-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 16841-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 16841-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |