Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 15053-2008 English PDF

US$349.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 15053-2008: Standard method for using radio chromic film and polymethylmethacrylate dosimetry system to measure absorbed dose
Status: Valid

GB/T 15053: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 15053-2008349 Add to Cart 3 days Standard method for using radio chromic film and polymethylmethacrylate dosimetry system to measure absorbed dose Valid
GB/T 15053-1994279 Add to Cart 3 days Standard method for using radiochromic film and polymthymethacrylate dosimetry systems to measure absorbed dose Obsolete

Similar standards

JJF 1234   JJG 188   GB/T 14365   GB/T 25439   GB/T 15447   GB/T 15446   

Basic data

Standard ID: GB/T 15053-2008 (GB/T15053-2008)
Description (Translated English): Standard method for using radio chromic film and polymethylmethacrylate dosimetry system to measure absorbed dose
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: A58
Classification of International Standard: 17.240
Word Count Estimation: 15,155
Date of Issue: 2008-09-19
Date of Implementation: 2009-08-01
Older Standard (superseded by this standard): GB/T 15053-1994
Quoted Standard: GB/T 15446; GB/T 15447; GB/T 16509; GB/T 16510; GB/T 16640; ICRU Report No. 60
Adopted Standard: ISOASTM 51275-2004, NEQ; ISOASTM 51276-2002, NEQ
Regulation (derived from): Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the use of radiant color film and poly (methyl methacrylate) (PMMA) Determination of absorbed dose dosimetry systems operation and measurement procedures. This standard applies to both dosimetry systems measure photon or electron irradiation of water absorbed dose represents the absorbed dose according to the material. Both dose measurement system is defined as working-level dosimetry systems (see GB/T 16640).

GB/T 15053-2008: Standard method for using radio chromic film and polymethylmethacrylate dosimetry system to measure absorbed dose


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Standard method for using radiochromic film and polymethylmethacrylate dosimetry system to measure absorbed dose ICS 17.240 A58 National Standards of People's Republic of China Replacing GB/T 15053-1994 The use of radiation color film and polymethyl methacrylate Dosimetry systems measure absorbed dose method (ISO /ASTM51275.2004, Standardpracticeforuseofradiochromic filmdosimetrysystem; ISO /ASTM51276.2002, Standardpractice foruseofpolymethylmethacrylatedosimetrysystem, NEQ) Posted 2009-08-01 2008-09-19 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard corresponds to ISO /ASTM51275.2004 "the use of radiation color film dosimetry system standards" (in English) and ISO / ASTM51276.2002 "using polymethylmethacrylate dosimetry system standards" (in English), and ISO /ASTM51275.2004 And ISO /ASTM51276.2002 non-equivalent. The technical differences between the standards with international standards as follows. a) The ISO /ASTM51275 and ISO /ASTM51276 merge the contents of two international standards for our country standard; b) In the ISO /ASTM51276.2002 standard Information Appendix A of the original content, based on the increase of the radiation dosimeter color film Relevant content (see Appendix A). For ease of use, this standard also made the following editorial changes. c) according to the Chinese custom for some formatting has been modified. d) In the second chapter, "normative references", the referenced ISO and ASTM standards, who have converted to our standards (including meter The amount of test regulations), the reference to our standards. This standard replaces GB/T 15053-1994 "use of radiation color film and polymethyl methacrylate absorbed dose measurement system Standard Method "dose. Compared with the standard GB/T 15053-1994 The main changes are as follows. --- Redefined the dosimeters used for radiant energy and the irradiation temperature range (see 1994 edition of 1.2.1,1.2.2; Excerpts 1.2.1,1.2.2); --- Added "Normative references" (see Chapter 2 of this edition); --- In the "Terms and definitions" clause added some terminology, and some of the terms of the original redefined (see 1994 edition Excerpts of chapter 3); Chapter 2; --- The title of "equipment" chapter to "dose measurement system" (see the 1994 version of Chapter 4; Chapter 5 of this edition); --- Added "equipment performance check" the technical content (see Chapter 6 of this edition, 6.1, 6.2); --- On the "Calibration of dosimetry systems" chapters made big adjustment, and added, "is calibrated dosimeter share volume in the radiation field Changes in dose rate should be less than ± 1% (range ≤2%) "requirements (see the 1994 version of Chapter 5; Chapter 7 of this edition); --- Added "Batch dosimeters characterization" of the technical content (see Chapter 9 edition); --- Increased "dose measurement system application" of technical content (see edition Chapter 10); --- Use the "Measurement Uncertainty" in chapter headings and related technical content replaces the 1994 version of the "Error Analysis" technical content (see 1994 version of Chapter 8; first edition Chapter 12); Appendix A of this standard is an informative annex. The standard proposed by China National Nuclear Corporation. This standard by the National Standardization Technical Committee of nuclear energy. This standard was drafted. China Institute of Metrology. The main drafters. Zhang Yanli, summer shading, Gong Xiaoming. This standard replaces the standards previously issued as follows. --- GB/T 15053-1994. The use of radiation color film and polymethyl methacrylate Dosimetry systems measure absorbed dose method

1 Scope

1.1 standard specifies the use of radiation color film and polymethyl methacrylate (PMMA) dosimetry systems for measuring absorbed dose of exercise For and measurement procedures. This standard applies to both dosimetry systems measure the photon or electron irradiation dose absorbed water is expressed according to the material The absorbed dose. Both dose measurement system is as working-level dose measuring system (see GB/T 16640). 1.2 This standard specifies two doses of the measurement system applicable conditions are as follows. 1.2.1 radiation color film dosimetry system a) absorbed dose range. 1Gy ~ 100kGy. b) absorbed dose rate range. 1 × 10-2Gy · s-1 ~ 1 × 1013Gy · s-1. c) radiation energy range. 0.1MeV ~ 50MeV (photons and electrons). d) irradiation temperature range. -78 ℃ ~ 60 ℃. 1.2.2 polymethyl methacrylate (PMMA) dosimetry systems a) absorbed dose range. 0.1Gy ~ 100kGy. b) absorbed dose rate range. 1 × 10-2Gy · s-1 ~ 1 × 107Gy · s-1. c) radiation energy range. 0.1MeV ~ 50MeV (photon); 3MeV ~ 50MeV (electrons). d) irradiation temperature range. -78 ℃ ~ 50 ℃. 1.3 This standard does not involve safety problems associated with its use (if it exists). Users of this standard is responsible for establishing the applicable safety and health Standards, and prior to use to determine the applicable limits.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 15446 doses of radiation processing of academic language GB/T 15447 X, γ-rays and electron beams of different materials absorbed dose conversion method GB/T 16509 doses of radiation processing Uncertainty Evaluation Guidelines GB/T 16510 radiation processing dosimetry calibration laboratory competency requirements Selection and calibration of the guide GB/T 16640 dosimetry systems for radiation processing is ICRU Report No. 60 of ionizing radiation and the amount of the basic unit

3 Terms and Definitions

GB/T 15446 and ICRU Report No. 60 and established the following terms and definitions apply to this standard. 3.1 Spectrophotometer or photometer instrument for measuring the absorbance of the solution or a film selected wavelength.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 15053-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 15053-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 15053-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 15053-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 15053-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15053-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.