GB/T 16639-2008 English PDFUS$214.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 16639-2008: Standard method for use of an alanine-EPR dosimetry system Status: Valid GB/T 16639: Historical versions
Basic dataStandard ID: GB/T 16639-2008 (GB/T16639-2008)Description (Translated English): Standard method for use of an alanine-EPR dosimetry system Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: A58 Classification of International Standard: 17.240 Word Count Estimation: 11,113 Date of Issue: 2008-09-19 Date of Implementation: 2009-08-01 Older Standard (superseded by this standard): GB/T 16639-1996 Adopted Standard: ISOASTM 51607-2004, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the use of alanine -EPR dosimetry systems measure photon and electron irradiation, the irradiated materials absorbed dose dosimeter materials involved in the choice of dosimeter preparation, equipment and dose measurement procedures. The system relies on electron paramagnetic resonance spectrometer alanine amino acid -derived free radicals measurements. The system was designated as the reference standard grade dosing system (see GB/T 16640). GB/T 16639-2008: Standard method for use of an alanine-EPR dosimetry system---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Standard method for use of an alanine-EPR dosimetry system ICS 17.240 A58 National Standards of People's Republic of China GB/T 16639-2008/ISO /ASTM51607.2004 Replacing GB/T 16639-1996 -EPR Using alanine dosimetry system Standard Method (ISO /ASTM51607.2004, Standardpractice foruseofanalanine-EPRdosimetrysystem, IDT) Posted 2008-09-19 2009-08-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard is identical with ISO /ASTM51607.2004 "-EPR using alanine dosimetry systems with standard practice" (in English). For ease of use, this standard made the following editorial changes. a) in accordance with Chinese custom to write some format has been modified. b) for ISO /ASTM51607. other international standards cited in 2004 have been adopted as the equivalent of a standard, this standard with References of these national standards or industry standards corresponding to international standards in place, the rest is not tantamount to the adoption of standard international standards, In this standard are a direct reference. This standard replaces GB/T 16639-1996 "Radiation Processing -EPR alanine dosimetry system." This standard and GB/T 16639-1996 compared to the main changes are as follows. --- Standard name to "use -EPR alanine dosimetry system standard method"; --- Radiation energy by the scope of "≤30MeV" to "0.1MeV ~ 28MeV" (1996 version of Chapter 1; this version 1.2.3); --- Redefined the standard "meaning and purpose", and added "4.3 Notes" content (the 1996 version of Chapter 4; Excerpts Chapter 4); --- Adjust the "dosimeters Preparation" chapter of the text content. The 1996 edition version 6.3.3 to 6.1 Note. --- In the "instrument" requirement adds to calibrate the instrument analytical balance technical requirements (1996 Version 7.1.3; Excerpts 7.1.2); --- Delete the words "establish the calibration curve," the technical requirements; and an increase in "8.1.4 Note 1", "8.1.4 Note 2" content (1996 Edition 8.5; Chapter 8 of this edition); --- Adjust the "EPR spectroscopy measurements" requirements; increased "9.1.5 Note", gives three methods of EPR spectra were corrected; --- Adjust the content of "Measurement Uncertainty" chapter; delete the contents of the 1996 version of 13.4 and 13.5. The standard proposed by China National Nuclear Corporation. This standard by the National Standardization Technical Committee of nuclear energy. This standard was drafted. China Institute of Metrology. The main drafters. Zhang Yanli, Liu Zhi cotton, summer shading, Zhang Hui. This standard replaces the previous standard edition published case. GB/T 16639-1996. GB/T 16639-2008/ISO /ASTM51607.2004 -EPR Using alanine dosimetry system Standard Method1 Scope1.1 standard specifies the use of alanine dosimetry system -EPR measured at photon and electron irradiation in the irradiated material absorbed dose Select the dosimeter material involved, namely the preparation of dose, dose measurement equipment and procedures. The system relies on electron paramagnetic resonance spectrometer Measurement of free radicals in alanine amino acid derivative. The system was designated as the reference standard level dosing system (see GB/T 16640). 1.2 This standard applies to the measurement of absorbed dose under the following conditions -EPR alanine dosimetry system. 1.2.1 absorbed dose range. 1Gy ~ 105Gy. 1.2.2 absorbed dose rate. ≤102Gy · s-1 (continuous radiation field). ≤5 × 107Gy · s-1 (pulsed radiation field) [1-3]. 1.2.3 radiation energy range. 0.1MeV ~ 28MeV [1,2,4]. 1.2.4 irradiation temperature range. -60 ℃ ~ 90 ℃ [2,5]. 1.3 SI units are given in value as the standard value, the value in parentheses is for reference only. 1.4 This standard does not involve security issues associated with its use. Users of this standard is responsible for establishing the applicable safety and health standards and make Before use to determine its limits applicable.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 16509 radiation processing dosimetry Uncertainty Evaluation Guidelines (GB/T 16509-2008, ISO /ASTM51707.2005, IDT) GB/T 16510 radiation absorbed dose calibration laboratory processing capacity requirements (GB/T 16510-2008, ISO /ASTM 51400.2002, IDT) Selection and calibration of the guide GB/T 16640 dosimetry systems for radiation processing is (GB/T 16640-2008, ISO /ASTM 51261.2002, IDT) ISO Guide to the Expression of Uncertainty in Measurement file ISO /ASTM51204 γ irradiation facility for food processing Practical guide of dosimetry ISO /ASTM51431 electrons and bremsstrahlung irradiation facility for food processing dosimetry practice ASTME170 radiation dose measurement and academic language ASTME668 using thermoluminescence (TLD) dosimetry systems for electronic equipment to determine the absorbed dose of radiation damage test in practice ICRU Report No. 14 Radiation Dosimetry. the maximum photon energy 0.6Mev ~ 25MeV X-rays and γ-rays ICRU Report No. 17 radiation dosimetry. a tube voltage of 5kV ~ 150kV X-ray generating means ICRU Report No. 34 pulse radiation dosimetry ICRU Report No. 35 of the initial energy of 1MeV ~ 50MeV electron beam radiation dosimetry ICRU Report No. 37 electrons and positrons stopping power ICRU Report No. 44 radiation dosimetry and measurement of tissue-equivalent ICRU Report No. 60 of ionizing radiation and the amount of the basic unit GB/T 16639-2008/ISO /ASTM51607.2004 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 16639-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 16639-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 16639-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 16639-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 16639-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 16639-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |