GB/T 15175-2012: Measurement methods for main parameter of solid state lasers
Status: Valid

GB/T 15175: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 15175-2012579 Add to Cart 5 days Measurement methods for main parameter of solid state lasers Valid
GB/T 15175-1994839 Add to Cart 6 days Measurement methods for main parameter of solid-state lasers Obsolete

Similar standards

GB/T 7247.1   GB/T 18490.1   GB/T 30117.2   GB/T 45239   GB/T 22453   GB/T 18462   

Basic data

Standard ID: GB/T 15175-2012 (GB/T15175-2012)
Description (Translated English): Measurement methods for main parameter of solid state lasers
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: L51
Classification of International Standard: 31.260
Word Count Estimation: 25,261
Older Standard (superseded by this standard): GB/T 15175-1994
Quoted Standard: GB 7247.1; GB/T 15313
Regulation (derived from): National Standards Bulletin No. 41 of 2012
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the main parameters of solid-state laser measurement method. This standard applies to solid-state laser (hereinafter referred to as "laser") the main parameters of the measurements.

GB/T 15175-2012: Measurement methods for main parameter of solid state lasers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS31.260 L51 National Standards of People's Republic of China Replacing GB/T 15175-1994 The main parameters of solid-state laser measurement method Issued on. 2013-06-01 2012-12-31 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms, definitions and symbols 1 4 2 General requirements 4.1 Measurement Condition 2 4.2 measurement apparatus 2 4.3 Security 2 4.4 test laser 2 4.5 Preparation for measurement 2 5 main parameters of the laser measurement method 2 5.1 peak wavelength of 2 5.2 Continuous Power 3 5.3 Pulse repetition frequency 4 5.4 pulse energy 5 Pulse width 5.5 6 5.6 Peak power 6 5.7 beam width or beam diameter of 6 5.8 beam divergence angle of 10 5.9 beam quality 11 5.10 output instability 13 5.11 degree of polarization 14 5.12 Threshold 15 Electro-optical conversion efficiency 16 5.13 5.14 beam pointing instability Test Method 17 (Normative) expression beam width or beam diameter Appendix A 19 Correction formula in Appendix B (informative) beam width of 20 Annex C (informative) Derivation object space beam waist diameter is calculated 21

Foreword

This standard rule according to GB/T 1.1-2009 given draft. This standard replaces GB/T 15175-1994 "solid-state lasers main parameters of the test method." This standard and GB/T 15175-1994 compared to the main changes are as follows. --- Quoted in Chapter 3 GB/T 15313, delete the original standard and GB/T 15313 the same content of terms and definitions; --- Chapter 4 adds provisions "arbitration measure atmospheric conditions"; --- Delete the original standard "transverse mode mode" measuring method (see 1994 edition 5.3); --- In the "beam width or beam diameter" measurement method increases the measurement "hollow probe method" (see 5.7); --- Increase "beam quality" measurement methods (see 5.9); --- States that the "degree of polarization" specific content measurement method, delete the original standard GB/T 7257 "helium-neon laser parameters tested party Law "reference (see 5.11); --- Added Appendix A, Appendix B and Appendix C. The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China. The standard by the China Electronics Standardization Institute. This standard was drafted. China Electronics Standardization Institute. The main drafters. Zhang Peng, Chen Lan. This standard replaces the standards previously issued as follows. --- GB/T 15175-1994. The main parameters of solid-state laser measurement method

1 Scope

This standard specifies the method for measuring the main parameters of solid-state lasers. The main measurement standard applies to solid-state lasers (hereinafter referred to as "laser") parameters.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated edition applies to this article Member. For undated references, the latest edition (including any amendments) applies to this document. Safety - Part 1 GB 7247.1 laser products. Equipment classification, requirements GB/T 15313 Laser term 3 Terms, definitions and symbols GB/T 15313 and established the following terms and definitions apply to this document. 3.1 Operating current operatingcurrents When the laser is operating, the pump source operating current. 3.2 Working conditions operatingconditions Laser operating conditions refer to its operating mode and the operating wavelength and other conditions. 3.3 Output instability outputinstability 3.3.1 Output power instability outputpowerinstability SP Output power within a predetermined time interval fluctuate over time characteristics when the laser is operating properly. 3.3.2 Output energy instability outputenergyinstability SQ Energy output within the specified time intervals fluctuate over time characteristics when the laser is operating properly. 3.4 The maximum beam offset beammaximalexcursion Δθmax Within a certain time frame, the maximum angle of deviation from the center of the beam spot of the optical axis. 3.5 Repeat pulse average power output repetitionpulseoutputaveragepower Repeat pulse laser under specified operating conditions, over a period of time of the n-times the average output power measurement.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 15175-2012_English be delivered?

Answer: Upon your order, we will start to translate GB/T 15175-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 15175-2012_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 15175-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 15175-2012?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15175-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.