GB/T 14901-2008 English PDFUS$229.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 14901-2008: Test method for density of glass -- Method of the sink-float comparison Status: Valid GB/T 14901: Historical versions
Basic dataStandard ID: GB/T 14901-2008 (GB/T14901-2008)Description (Translated English): Test method for density of glass -- Method of the sink-float comparison Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: Q33 Classification of International Standard: 81.040 Word Count Estimation: 10,176 Date of Issue: 2008-11-12 Date of Implementation: 2009-09-01 Older Standard (superseded by this standard): GB/T 14901-1994 Quoted Standard: GB/T 2540 Regulation (derived from): National Standard Approval Announcement 2008 No.19 (Total No.132) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the determination of the density of the glass with the ups and downs of comparative law instruments, measurement procedure and the results of calculations. This standard applies to the determination of the density -density glass or other non-porous solid 1. 1g/cm3 ~ 3. 3g/cm3 can also be used to determine the apparent density ceramic or known porosity of solids. GB/T 14901-2008: Test method for density of glass -- Method of the sink-float comparison---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Test method for density of glass. Method of the sink-float comparison ICS 81.040 Q33 National Standards of People's Republic of China Replacing GB/T 14901-1994 Glass densitometry ups and downs of Comparative Law Posted 2008-11-12 2009-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard replaces GB/T 14901-1994 "glass density determination ups and downs of Comparative Law." Compared with the standard GB/T 14901-1994 The main changes are as follows. --- Reagent section made editorial changes (the 1994 edition of Chapter 5, Section 4 of this edition), methylene iodide to methylene iodide; --- Instrument part made editorial changes (1994 edition, Chapter 4, Chapter 5 of this edition); --- Reference standard sample and the sample position made changes (1994 Edition Chapter 6, edition 4.4). Appendix A of this standard is a normative appendix. The standard proposed by China Building Materials Federation. This standard by the National Standardization Technical Committee of architectural glass (SAT/T C255) centralized. This standard is drafted by. Qinhuangdao Glass Industry Research and Design Institute. The main drafters of this standard. tube Shifeng, Liu Fu, Luwan Shun, Han Ying, TAN Xiao arrows. This standard replaces the standards previously issued as follows. --- GB/T 14901-1994. Glass densitometry ups and downs of Comparative Law1 ScopeThis standard specifies the determination of the density of the glass with the ups and downs of comparative law instruments, measurement procedures and the results of calculations. This standard applies to the determination of the density of the glass 1.1g/cm3 ~ 3.3g/cm3 or other non-porous solid density can also be used to determine the Ceramic or apparent density solid known porosity.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 2540 Petroleum products - Determination of density (pycnometer method) Principle 3 Since the thermal expansion coefficient of the standard density of the solution is much greater than the thermal expansion coefficient of the glass case, so the density of the density of the solution at elevated temperatures Value decreased much more than glass reference standards and the density value of the glass sample. At room temperature 20 ℃ ± 3 ℃, density greater than the density of the solution in a glass Standard reference density and glass samples, therefore, reference standard glass and glass samples floating on the density of the solution. Then three simultaneous rise Temperature and density of the solution when the density falls below standard sample and the sample density, at different temperatures, standards and samples were settling, according to the Shen Lower temperature, calculate the density of glass samples. Glass reference standard at 30 ℃ 1) when the density of the solution prepared in the settlement, glass samples at 20 ℃ ~ In the range of 40 ℃ settlement, therefore, can be measured with a standard deviation for the density of the sample ± 0.0200g/cm3 or less. 1) In order to facilitate rapid determination of the glass sample density glass, glass reference standards sedimentation temperature may be set in the range of 25 ℃ ~ 35 ℃.4 Reagents and materials4.1 Reagents Density of the solution formulated reagents should be of analytical grade or pure class distinctions. The reagents used are the following. a) isopropyl salicylate, 30 ℃ when the density of 1.10g/cm3; b) α- bromonaphthalene, 30 ℃ when the density of 1.48g/cm3; c) symmetry - Tetrabromoethane, 30 ℃ when the density of 2.96g/cm3; d) diiodomethane, 30 ℃ when the density of 3.32g/cm3. Note. Due to methylene iodide, α- bromonaphthalene and symmetry - Tetrabromoethane having photosensitivity, it should be kept in a light-shielding container. Density of the solution should be prepared on the light-shielding container Saved. Diiodomethane put a piece of copper wire to slow decomposition of methylene iodide. Preparation 4.2 density of the solution Choice of two 4.1 reagent preparation solution density, volume density values \u200b\u200bof the two agents need to be formulated with the density of the solution varies. The volume of each reagent required, by the following equation. s = ρ1 ρs Vp Vp Vp 1 + ρ2 2 (1) S = 1 + Vp Vp Vp 2 (2) ρs = ρ Vp 1 Vp 1 + ρ2 2 Vp Vp 2 1+ (3) ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 14901-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 14901-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 14901-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 14901-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 14901-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14901-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |