| GB/T 14642-2009 English PDFUS$329.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 14642-2009: Industrial circulating cooling water and boiler water -- Determination of fluoride, chloride, phosphate, nitrite, nitrate and sulfate -- Ion chromatography Status: Valid GB/T 14642: Historical versions
 Basic dataStandard ID: GB/T 14642-2009 (GB/T14642-2009)Description (Translated English): Industrial circulating cooling water and boiler water -- Determination of fluoride, chloride, phosphate, nitrite, nitrate and sulfate -- Ion chromatography Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G76 Classification of International Standard: 71.040.40 Word Count Estimation: 14,113 Date of Issue: 2009-05-18 Date of Implementation: 2010-02-01 Older Standard (superseded by this standard): GB/T 14642-1993 Adopted Standard: ASTM D4327-2003, NEQ Regulation (derived from): National Standard Announcement 2009 No.6 (Total No.146) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the determination of industrial cooling water and boiler water fluoride ion (F-) ion chromatography, chloride ions (C1-), phosphate ion (PO43-), nitrite (NO2-), nitrate ion (NO3-), sulfate ions (SO4-) method. This standard applies to industrial cooling water and boiler water fluoride content 0. 10 mg/L ~ 100. 0 mg/L, chloride ion content of 0. 10 mg/L ~ 500. 0 mg/L, phosphate ion content of 0. 10 mg/L ~ 100. 0 mg/L, sulfate ion content of 0. 20 mg/L ~ 500. 0 mg/L measurement range, nitrate ion content of 0. 10 mg/L ~ 100. 0 mg/L, nitrite ion content of 0. 10 mg/L ~ 100. 0 mg/L. This standard also applies to surface water, groundwater and other industrial water fluoride ion (F-), chloride ions (C1-), phosphate ion (PO43-), nitrite (NO2-), nitrate ion (NO3-), sulfate ion (SO42-) determination of plasma. GB/T 14642-2009: Industrial circulating cooling water and boiler water -- Determination of fluoride, chloride, phosphate, nitrite, nitrate and sulfate -- Ion chromatography---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Industrial circulating cooling water and boiler water. Determination of fluoride, chloride, phosphate, nitrite, nitrate and sulfate. Ion chromatography ICS 71.040.40 G76 National Standards of People's Republic of China Replacing GB/T 14642-1993 Industrial circulating cooling water and boiler water Fluorine, chlorine, phosphoric acid, nitrite, nitrate and Determination of sulfate ion chromatography Posted 2009-05-18 2010-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard corresponds to ASTMD4327.2003 "Standard Test Method for Determination of anions in water chemical suppression Ion Chromatography" (English Edition), and ASTMD4327.2003 is non-equivalent. This standard replaces GB/T 14642-1993 "industrial circulating cooling water and boiler water, fluoride, chloride, phosphate, nitrite, nitrate and Sulfate by ion chromatography. " The main changes in the standards and GB/T 14642-1993, compared as follows. --- Given ion chromatography flow path diagram in the method of the feed; --- Added "5 interference." The Standard Appendix A, Appendix B, Appendix C are informative appendices. The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Standardization Technical Committee of Chemical Water Treatment Chemicals Branch (SAC/TC63/SC5) centralized. This standard is drafted by. Guangzhou City Special Pressure Equipment Inspection and Research Institute, CNOOC Tianjin Chemical Research & Design Institute. The main drafters of this standard. Zhou Guofu, Du Yuhui, Zhuzhuan Jun, Xie Haiyuan, Bai Ying. This standard was first published in 1993. Industrial circulating cooling water and boiler water Fluorine, chlorine, phosphoric acid, nitrite, nitrate and Determination of sulfate ion chromatography1 ScopeThis standard specifies the Ion Chromatography industrial circulating cooling water and boiler water fluoride ions (F-), chlorine ion (Cl-), phosphate ion (PO43-), nitrite (NO2-), nitrate ion (NO3-), sulfate ion (SO42-) method. This standard applies to industrial cooling water and boiler water fluoride content of 0.10mg/L ~ 100.0mg/L; chloride ion content 0.10mg/L ~ 500.0mg/L; phosphate ion content of 0.10mg/L ~ 100.0mg/L; nitrite ion content of 0.10mg/L ~ 100.0mg/L; a nitrate ion content of 0.10mg/L ~ 100.0mg/L; a sulfate ion content 0.20mg/L ~ 500.0mg/L range Determination. This standard also applies to surface water, ground water and other industrial water fluoride ion (F-), chlorine ion (Cl-), phosphate ion (PO43-), nitrite (NO2-), nitrate ion (NO3-), sulfate ion (SO42-) plasma was measured.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. Preparation of standard solution of GB/T 602 chemical reagent determination of impurities (GB/T 602-2002, ISO 6353-1. 1982, NEQ) GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3696. 1987, MOD) GB/T 6907 boiler water and cooling water analysis water sample collection methods3 Terms and DefinitionsThe following terms and definitions apply to this standard. 3.1 By ion exchange separation of ionic components, and then use the appropriate detector, it is a branch of high-performance liquid chromatography. 3.2 Before separation column placed to protect the separation column against particulate matter or irreversible contamination of impurities such reservations. 3.3 According to the detected ion retention characteristics, it will be detected prior to detection of the ion exchange column separation. 3.4 After the guard column is connected in one or more separation columns for separating the composition of a series of test ion analysis system. All the pillars of the series The total capacity of the column analytical column with the contribution. 3.5 Installed between the analytical column and a detector for detecting the response lotion reduce leaching of ionic components, in response to detection of an increase of the detected ion, ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 14642-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 14642-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 14642-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 14642-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 14642-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14642-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |