| GB/T 14598.13-2008 English PDFUS$359.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 14598.13-2008: Electrical relays -- Part 22-1: Electrical disturbance tests for measuring relays and protection equipment. 1 MHz burst immunity tests Status: Obsolete GB/T 14598.13: Historical versions
 Basic dataStandard ID: GB/T 14598.13-2008 (GB/T14598.13-2008)Description (Translated English): Electrical relays -- Part 22-1: Electrical disturbance tests for measuring relays and protection equipment. 1 MHz burst immunity tests Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K45 Classification of International Standard: 29.120.70 Word Count Estimation: 9,939 Date of Issue: 2008-06-18 Date of Implementation: 2009-03-01 Older Standard (superseded by this standard): GB/T 14598.13-1998 Quoted Standard: GB/T 14047-1993; IEC 61000-4-18-2006 Adopted Standard: IEC 60255-22-1-2007, MOD Regulation (derived from): Announcement of Newly Approved National Standards No. 10 of 2008 (total 123) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies requirements for 1MHz and 100kHz burst immunity test the general requirements for these tests used in power system protection Measuring relays and protection equipment. Including use with these devices to control, monitor, and process interface device. Test purpose is to verify the test device is energized and be bound by, such as in high-voltage substation or power plant occurred breaker or disconnector open or closed caused by repeated harassment oscillation damping can work correctly. The requirements of this section apply to new measuring relays and protection equipment, as provided in this section all the tests only type testing. GB/T 14598.13-2008: Electrical relays -- Part 22-1: Electrical disturbance tests for measuring relays and protection equipment. 1 MHz burst immunity tests---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Electrical relays Part 22-1. Electrical disturbance tests for measuring relays and protection equipment 1 MHz burst immunity tests ICS 29.120.70 K45 National Standards of People's Republic of China Replacing GB/T 14598.13-1998 Electrical relays Part 22-1. Measuring relays and protection equipment Electrical disturbance tests 1MH z burst immunity test (IEC 60255-22-1.2007, MOD) Posted 2009-03-01 2008-06-18 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThe partial modification of international standard IEC 60255-22-1.2007 "Electrical relays - Part 22-1. Measuring relays and protection devices Set Electrical disturbance tests --- 1MHz burst immunity test "(in English). According to the actual situation of the power system, this part uses IEC 60255-22-1.2007 when the development of national standards, to retain the Content 100kHz burst test GB/T 14598.13-1998, and adopted the IEC 61000-4-18.2006 in 100kHz pulse Chong group specified tests. For ease of use, this section made the following editorial changes. a) 'this International Standard' to replace the word 'this section'; b) with a decimal point '. 'Instead of as a decimal point,' '; c) Remove the preface to international standards. This Part replaces GB/T 14598.13-1998 "Measuring Electrical disturbance tests for measuring relays and protection equipment - Part 1. 1MHz Burst disturbance test. " This portion of the GB/T 14598.13-1998 main changes are as follows. --- In this part of IEC 61000-4-18 is based; --- Grounded at one end only when shielded communication line test, increasing the coupling capacitance; --- Clear test program communication port; --- Test length of communication cable is fixed to 10m; --- Removed ground Fig. 4 test generator terminals; --- The concept of "port", the severity and the test voltage according to the different ports specified tests; --- Detailed description of the test configuration; --- Test severities for the fixed level (equivalent to the original standard grade 3); --- According to different functions of the device specified acceptance criteria; --- Removed Appendix A. This part is proposed by the China Electrical Equipment Industrial Association. The measure in part by the National Standardization Technical Committee centralized relays and protection equipment. This part mainly drafted by. National relay protection and automation equipment for Quality Supervision and Inspection Center, Nanjing NARI-RELAYS Electric Co. Division, Beijing Sifang Automation Co., Ltd., Guodian Nanjing Automation Co., Ltd., Beijing Purple Control Co., Ltd., Hebei Power company, Zhuhai Wanlida Electric Co., Ltd., Yantai Dongfang Electronics Information Industry Co., XJ Electric Company Limited Division of Xuchang Relay Research Institute. The main drafters of this section. Liquan Xi, anti-Lee, Fan, Geng Yan, GE Rong Shang, Caoshu Jiang, Wang Lei, Zhaoguo Gang, Jin Quanren, Yanghui Xia?. This part of the standard replaces the previous editions are. --- GB/T 14598.13-1998. Electrical relays Part 22-1. Measuring relays and protection equipment Electrical disturbance tests 1MH z burst immunity test1 ScopeGB/T 14598 in this section to IEC 61000-4-18, based on reference to the applicable sections of this publication, provides for 1MHz General requirements and 100kHz burst immunity test, these tests are suitable for power system protection used for measuring relays and protection Protection devices. Including the control, monitoring and process interface equipment used in conjunction with these devices. Trial is to verify the device under test is energized, and by the circuit breaker, such as occurred in the high-voltage substation or power plant or isolation Repetitive damped oscillatory knife open or closed caused by harassment can work correctly. The requirements of this section apply to new measuring relays and protection equipment, all the tests specified in this section only type testing. The purpose of this section is to provide. --- The definitions of terms used; --- Test severity; --- Test equipment; --- Test configuration; --- Test procedures; --- Acceptance criteria; ---experiment report.2 Normative referencesThe following documents contain provisions which, through reference GB/T 14598 in this section constitute provisions of this section. For dated references, All subsequent amendments (excluding corrections) or revisions do not apply to this section, however, encourage an agreement under this section Parties to study the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 14047-1993 measuring relays and protection equipment (idt IEC 60255-6. 1988) IEC 61000-4-18.2006 Electromagnetic compatibility - Part 4-18. Testing and measurement techniques --- damped oscillation immunity test3 Terms and DefinitionsThe following terms and definitions apply to this section. 3.1 And provides a signal to be used to verify the performance of the pilot plant is a pilot plant for the equipment required for normal operation. 3.2 It is ac or dc auxiliary energizing quantity of the pilot plant input interface. 3.3 And a limited number of clearly discernible pulse or series of limited duration oscillation. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 14598.13-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 14598.13-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 14598.13-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 14598.13-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 14598.13-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14598.13-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |