GB/T 1408.3-2016 PDF EnglishUS$155.00 · In stock · Download in 9 seconds
GB/T 1408.3-2016: Insulating materials -- Test methods for electric strength -- Part 3: Additional requirements for 1.2/50μs impulse tests Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB/T 1408.3: Historical versions
Similar standardsGB/T 1408.3-2016: Insulating materials -- Test methods for electric strength -- Part 3: Additional requirements for 1.2/50μs impulse tests---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT1408.3-2016 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.035.99 K 15 GB/T 1408.3-2016 / IEC 60243-3:2013 Replacing GB/T 1408.3-2007 Insulating Materials – Test Methods for Electric Strength – Part 3: Additional Requirements for 1.2/50μs Impulse Tests (IEC 60243-3:2013, Electric Strength of Insulating Materials – Test Methods – Part 3: Additional Requirements for 1.2/50μs Impulse Tests, IDT) ISSUED ON: DECEMBER 13, 2016 IMPLEMENTED ON: JULY 1, 2017 Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the People’s Republic of China. Table of ContentsForeword ... 3 1 Scope ... 5 2 Normative References ... 5 3 Terms and Definitions ... 5 4 Significance of the Test ... 6 5 Electrodes and Test Specimens ... 7 6 Conditioning before Tests ... 7 7 Surrounding Medium ... 7 8 Electrical Apparatus ... 8 9 Procedure ... 8 10 Application of Voltage ... 8 11 Criterion of Breakdown ... 9 12 Number of Tests... 9 13 Report ... 10ForewordGB/T 1408 Electrical Strength of Insulating Materials - Test Methods consists of the following 3 parts: --- Part 1: Tests at Power Frequencies; --- Part 2: Additional Requirements for Tests Using Direct Voltage; --- Part 3: Additional Requirements for 1.2/50μs Impulse Tests. This Part is Part 3 of GB/T 1408. This Standard was drafted as per the rules specified in GB/T 1.1-2009. This Part replaced GB/T 1408.3-2007 Electric Strength of Insulating Materials Test Methods - Part 3: Additional Requirements for 1.2/50μs Impulse Tests. Compared with GB/T 1408.3-2007, the major technical changes of this Part are as follows: --- Modify GB/T 1408.1-2006 into “GB/T 1408.1-2016” in the whole text; --- Modify “pulse” into “impulse” in the whole text; --- Change the term "virtual" to "apparent" (see 3.3~3.6 of this Edition; 3.3~3.6 of the 2007 Edition); --- Add the terms "impulse breakdown voltage" and "withstand voltage" (see 3.7 and 3.8 of this Edition); --- Modify "report content". This Part uses translation method to equivalently adopt IEC 60243-3:2013 Electric Strength of Insulating Materials – Test Methods – Part 3: Additional Requirements for 1.2/50μs Impulse Tests (The 3rd Version). This Part was proposed by China Electrical Equipment Industry Association. This Part shall be under the jurisdiction of National Technical Committee on Electrical Insulating Materials and Insulating System Evaluation of Standardization Administration of China (SAC/TC 301). Drafting organizations of this Part: Machinery Industry Beijing Electrotechnical Institute of Economic Research; Jiaxing New World Electromechanical Co., Ltd.; Foshan Shunde Quality and Technical Supervision Standards and Coding Institute; Guilin Electrical Equipment Scientific Research Institute Co., Ltd.; and Beijing BEIZHONG Stem Turbine Generator Co., Ltd. Insulating Materials – Test Methods for Electric Strength – Part 3: Additional Requirements for 1.2/50μs Impulse Tests1 ScopeThis Part of GB/T 1408 gives requirements additional to those in GB/T 1408.1 for the determination of the electric strength of solid insulating materials under 1.2/50μs impulse voltage stress.2 Normative ReferencesThe following documents are essential to the application of this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this Document. GB/T 1408.1-2016 Electrical strength of insulating materials - Test methods - Part 1: Tests at power frequencies (IEC 60243-1:2013, IDT)3 Terms and DefinitionsFor the purposes of this Document, the terms and definitions given in GB/T 1408.1-2016 apply. 3.1 Full impulse-voltage wave Aperiodic transient voltage that rises rapidly to a maximum value, then falls less rapidly to zero (see Figure 1). 3.2 Peak value (of an impulse-voltage wave); UP Maximum value of voltage. 3.3 Virtual peak value of an impulse-voltage wave; U1 Value derived from a recording of an impulse-voltage wave on which high-frequency oscillations, or overshoot of a limited magnitude, may be present. 3.4 Virtual origin of an impulse-voltage wave; O1 peak voltages. The peak voltage of the initial set should be approximately 70 % of the expected breakdown voltage. Increase the peak voltage of successive sets by 5 % ~ 10 % of the peak value of the first set. Table 1 of GB/T 1408.1-2016 is applicable. Allow sufficient time between successive impulses for the generator to become completely charged. Normally, a time of three times the charging time constant for the generator is sufficient. Sufficient time shall also be allowed between successive impulses to allow dissipation of any injected space-charge. For many materials, the charging time of the generator will cover this eventuality. For materials having a longer space-charge retention time, the necessary time shall be specified in the material specification sheet. If this information is not known, but a long space-charge retention period is suspected, then additional tests should be run with longer intervals between impulses, to determine if a significant difference in breakdown values is obtained. A valid test on a test specimen is one in which impulse waves are applied at least two voltage levels without breakdown, before breakdown occurs at the third or a subsequent level. The electric strength shall be based on the virtual peak voltage of the last set of three waves which was applied without breakdown. The breakdown voltage is the nominal voltage of the next set of waves causing breakdown. When using asymmetrical electrode systems, preliminary tests shall be conducted to determine the polarity which yields the lower breakdown voltage. If significant differences are obtained, the polarity giving the lower test results should be used. 10.2 Proof tests One set of three impulses of specified proof voltage (virtual value) shall be applied to the test specimen in accordance with Clause 11 of GB/T 1408.1-2016. When necessary for calibration purposes, up to three impulses with peak voltages not exceeding 80 % of the proof voltage may be applied prior to the application of the proof voltage waves.11 Criterion of BreakdownClause 11 of GB/T 1408.1-2016 is applicable.12 Number of TestsClause 12 of GB/T 1408.1-2016 is applicable. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 1408.3-2016 be delivered?Answer: The full copy PDF of English version of GB/T 1408.3-2016 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 1408.3-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 1408.3-2016_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 1408.3-2016 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version GB/T 1408.3-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 1408.3-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of GB/T 1408.3-2016?A step-by-step guide to download PDF of GB/T 1408.3-2016_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 1408.3-2016". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |