GB/T 14048.13-2017: Low-voltage switchgear and controlgear -- Part 5-3: Control circuit devices and switching elements -- Requirements for proximity devices with defined behaviour under fault conditions (PDDB)
Status: Valid

GB/T 14048.13: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 14048.13-2017519 Add to Cart 5 days Low-voltage switchgear and controlgear -- Part 5-3: Control circuit devices and switching elements -- Requirements for proximity devices with defined behaviour under fault conditions (PDDB) Valid
GB/T 14048.13-2006919 Add to Cart 4 days Low-voltage switchgear and controlgear -- Part 5-3: Control circuit devices and switching elements -- Requirements for proximity devices with defined behaviour under fault conditions (PDF) Obsolete

Similar standards

GB/T 14048.11   GB/T 14048.3   GB 14048.1   GB/T 14048.9   GB/T 14048.22   GB/T 14048.4   

Basic data

Standard ID: GB/T 14048.13-2017 (GB/T14048.13-2017)
Description (Translated English): Low-voltage switchgear and controlgear -- Part 5-3: Control circuit devices and switching elements -- Requirements for proximity devices with defined behaviour under fault conditions (PDDB)
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K30
Classification of International Standard: 29.130.20
Word Count Estimation: 26,223
Date of Issue: 2017-09-29
Date of Implementation: 2018-04-01
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 14048.13-2017: Low-voltage switchgear and controlgear -- Part 5-3: Control circuit devices and switching elements -- Requirements for proximity devices with defined behaviour under fault conditions (PDDB)



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Low-voltage switchgear and controlgear - Part 5-3. Control circuit devices and switching elements - Requirements for proximity devices with defined behavior under fault conditions (PDDB) ICS 29.130.20 K30 National Standards of People's Republic of China Replacing GB/T 14048.13-2006 Low-voltage switchgear and control equipment Part 5-3. Control circuit devices and switching elements In the fault conditions have a definite function Proximity Switch (PDDB) requirements Part 5-3.Controlcircuitdevicesandswitchingelements- faultconditions (PDDB) (IEC 60947-5-3.2013, IDT) 2017-09-29 Release.2018-04-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 General 1 2 Terms, definitions and abbreviations 2 3 Categories 8 4 Features 8 5 product information 8 6 normal use, installation and transportation conditions 9 7 Structure and performance requirements 9 8 Test 13 9 amendment 14 Appendix A (informative) Example of a simple control system complying with the IEC 61511 series of standards References 19

Foreword

"Low-voltage switchgear and control equipment" consists of the following components. --- Part 1. General principles; --- Part 2. Circuit breakers; --- Part 3. Switches, isolators, disconnectors and fuse combinations; --- Part 4-1. Contactors and Motor Starters Electromechanical contactors and motor starters (including motor protectors); --- Part 4-2. Contactors and Motor Starters Semiconductor Controllers and Starters for AC Motors (Including Soft Starters); --- Part 4-3. Contactors and motor starters AC semiconductor controllers and contactors for non-motor loads; --- Part 5-1. Control circuit devices and switching elements Electromechanical control circuit devices; --- Part 5-2. Control circuit appliances and switching elements proximity switch; --- Part 5-3. Control circuit devices and switching elements Proximity switch (PDDB) with defined function under fault conditions Claim; --- Part 5-4. Control circuit devices and switching elements small capacity contact performance evaluation method special test; --- Part 5-5 part of the control circuit electrical and switching elements with electrical mechanical locking latch emergency braking device; --- Part 5-6. DC link control circuit (NAMUR) for electrical and switching element proximity sensors and switching amplifiers; --- Part 5-7. Control circuit devices and switching elements for analog devices with the analog output requirements; --- Part 5-8. Control circuit electrical and switching elements three enable switch; --- Part 5-9. Control circuit electrical and switching components flow switch; --- Part 6-1. Multifunction electrical switch electrical appliances; --- Part 6-2. Multifunction Electrical Equipment (Equipment) Control and Protection Switching Equipment (CPS); --- Part 7-1. Auxiliary device copper conductor terminal block; --- Part 7-2. Auxiliary device copper conductor protective conductor terminal block; --- Part 7-3. Auxiliary fuses terminal block safety requirements; --- Part 8. Rotating motor with thermal protection (PTC) control unit. This section is "low-voltage switchgear and control equipment," Part 5-3. This section drafted in accordance with GB/T 1.1-2009 given rules. This Part replaces GB/T 14048.13-2006 "Low-voltage switchgear and control equipment Part 5-3. Control circuit devices and switches Elements with Proximity Switches (PDF) Requirements Under Fault Conditions ". This section compared with GB/T 14048.13-2006 main technical changes are as follows. --- Added terms and definitions related to failure, level of safety performance and structural limitations, etc., deleting terms related to integrated circuits; --- Added functional safety related specifications and usage information, and added performance to PDDB's ECM compatibility requirements Criteria and other aspects (see Chapter 7); --- Deleted the control and monitoring device design requirements (see 7.1); --- Deleted 8.7 "verification of determination of fault conditions" and 8.8 "Evaluation of programmable or composite integrated circuits" (see 8 chapters); --- Added "amendment" chapter (see Chapter 9); --- Standard full text is no longer related to integrated circuits and programming requirements, also deleted the original Appendix A "applied by the shadow of 8.7 and 8.8 LIST PDF Single Failure List of Electrical Equipment ", replace it with a new Appendix A (informative)" IEC 61511 compliant Column standard simple control system example. " This section uses the translation method identical with IEC 60947-5-3.2013 "low-voltage switchgear and control equipment Part 5-3. Control of electricity Road electrical appliances and switching elements in the fault conditions have determined the function of the proximity switch (PDDB) requirements. " The documents of our country that are consistent with the corresponding international documents that are normative references in this section are as follows. --- GB/T 14048.1-2012 low-voltage switchgear and control equipment Part 1. General (IEC 60947-1.2011, MOD); --- GB/T 14048.5-2008 Low-voltage switchgear and control equipment Part 5-1. Control circuit devices and switching elements Electromechanical control circuit appliances (IEC 60947-5-1.2003, MOD); Electromagnetic compatibility test and measurement techniques Electrostatic discharge immunity test (IEC 61000-4-2). 2001, IDT); --- GB/T 17626.3-2006 Electromagnetic compatibility test and measurement techniques RF electromagnetic field radiation immunity test (IEC 61000-4-3.2002, IDT); --- GB/T 17626.4-2008 Electromagnetic compatibility test and measurement techniques Fast transient impulse group immunity test (IEC 61000-4-4.2004, IDT); --- GB/T 17626.6-2008 electromagnetic compatibility test and measurement techniques RF field induced conduction disturbances immunity (IEC 61000-4-6.2006, IDT); Electromagnetic compatibility (EMC) - Testing and measurement techniques - Power frequency magnetic field immunity test (IEC 61000-4-8). 2001, IDT); --- GB/T 20438.1-2006 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1. General Seeking (IEC 61508-1.1998, IDT); --- GB/T 20438.2-2006 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2. Electrical / Requirements for electronic/programmable electronic safety related systems (IEC 61508-2.2000, IDT); --- GB/T 20438.3-2006 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3. Software requirements Seeking (IEC 61508-3.1998, IDT); --- GB 28526-2012 Mechanical and Electrical Safety Safety Functional Safety of Electrical, Electronic and Programmable Electronic Control Systems (IEC 62061.2005, IDT). This part made the following editorial changes according to the specific conditions of our country. --- Removed the terms and definitions of the index, and correction of article references the definition of article number. --- Removed 2.2.28 Central Plains Note 2, its content is only related to the choice of words in other language versions of different, has nothing to do with our country. This part is proposed by China Electrical Equipment Industry Association. This part of the National Standardization Technical Committee of low-voltage electrical (SAC/TC189) centralized. This section drafted unit. Shanghai Electric Apparatus Research Institute, Shanghai Electric Branch Electric Technology Co., Ltd., Zhejiang Chint Electric Co., Ltd. The main drafters of this section. Zhang Lili, Li Hui, Zeng Ping, Jin Haisheng. This part replaces the standards previously issued as. --- GB/T 14048.13-2006. Low-voltage switchgear and control equipment Part 5-3. Control circuit devices and switching elements In the fault conditions have a definite function Proximity Switch (PDDB) requirements

1 General

1.1 Scope This section of "Low-voltage switchgear and control equipment" is a supplement to GB/T 14048.10, provides a certain function of proximity to open Off (PDDB) Performance requirements under fault conditions. This section does not specify any other features required for a particular purpose. This section does not include proximity switches with analog output. This section does not address specific noise-related requirements, because the control circuit electrical appliances and switching noise can be regarded as non-hazardous. If the PDDB is used in some cases to meet the additional requirements specified in other standards, the requirements of the relevant standards apply. Compliance with this section does not guarantee the safety-related specific features. Moreover, this section does not specify the behavior of the PDDB or for subtraction Requirements for devices that interfere with each other, such as coded markings, with small switches. Therefore, in addition to the requirements of this section, the need to consider these and other needles Requirements for a specific purpose. Note 1. PDDB can also be used as an interlock (see ISO 14119) in view of its function under fault conditions. Note 2. The IEC 61496 series of standards give the requirements for electro-sensitive protective equipment for personnel testing. 1.2 Normative references The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 2423.1-2008 Environmental testing for electric and electronic products Part 2. Test methods Test A. Low temperature (IEC 60068-2- 1.2007, IDT) GB/T 2423.4-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Db alternating hot and humid (12h 12h cycle) (IEC 60068-2-30.2005, IDT) GB/T 4208-2008 enclosure protection (IP code) (IEC 60529.1989 A1.1999, IDT) GB/T 14048.10-2016 Low-voltage switchgear and control equipment Part 5-2. Control circuit appliances and switching elements close Switch (IEC 60947-5-2.2007 A1.2012, IDT) Safety of machinery - Part 1 of the safety control system for machinery - General principles of design (ISO 13849-1). 2006, IDT) Electromagnetic compatibility (EMC) test and measurement techniques Surge (immunity) immunity test (IEC 61000-4-5). 2005, IDT) GB/T 17626.11-2008 electromagnetic compatibility test and measurement techniques voltage dips, short interruptions and voltage variations immunity Test (IEC 61000-4-11.2004, IDT) IEC 60947-1-2007 low-voltage switchgear and control equipment Part 1. General (Low-voltagewitchgearandcon- trolgear-Part 1.Generalrules) IEC 60947-1.2007/A1.2010 No. 1 Amendment (Amendment1,2010) IEC 60947-5-1-2003 Low-voltage switchgear and controlgear - Part 5-1 - Control circuits Electrical and switchgear electromechanical
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 14048.13-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 14048.13-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 14048.13-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 14048.13-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 14048.13-2017?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14048.13-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.