Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 14048.4-2020 PDF English

US$1805.00 · In stock · Download in 9 seconds
GB/T 14048.4-2020: Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters(Including motor protector)
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

GB/T 14048.4: Historical versions

Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
GB/T 14048.4-20201805 Add to Cart Auto, 9 seconds. Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters(Including motor protector) Valid
GB 14048.4-2010RFQ ASK 11 days [Replaced by GB/T 14048.4-2020] Low-voltage switchgear and control gear -- Part 4-1: Contactors and motor-starters -- Electromechanical contactors and motor-starters (Including motor protector) Valid
GB 14048.4-2003RFQ ASK 7 days Low-voltage switchgear and controlgear -- Electromechanical contactors and motor-starters Obsolete
GB 14048.4-1993RFQ ASK 9 days Low-voltage switchgear and controlgear. Low-voltage electromechanical contactors and motor starters Obsolete

Similar standards

GB 14536.1   GB 14536.11   GB 14536.15   GB/T 14048.9   

GB/T 14048.4-2020: Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters(Including motor protector)


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT14048.4-2020
NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.130.20 K 32 Replacing GB/T 14048.4-2010 Low-voltage switchgear and controlgear - Part 4-1. Contactors and motor-starters - Electromechanical contactors and motor-starters (Including motor protector) (IEC 60947-4-1.2018, Low-voltage switchgear and controlgear - Part 4-1.Contactors and motor-starters - Electromechanical contactors and motor-starters, MOD) Issued on. SEPTEMBER 29, 2020 Implemented on. APRIL 01, 2021 Issued by. State Administration for Market Regulation; Standardization Administration of the PRC.

Table of Contents

Foreword... 4 Introduction... 9 1 Scope... 10 2 Normative references... 11 3 Terms, definitions, symbols and abbreviated terms... 13 4 Classification... 28 5 Characteristics of contactors and starters... 28 6 Product information... 48 7 Normal service, mounting and transport conditions... 53 8 Constructional and performance requirements... 53 9 Tests... 82 Annex A (Normative) Marking and identification of terminals of contactors and associated overload relays... 120 Annex B (Normative) Special tests... 122 Annex C (Informative) Typical characteristics of starters... 132 Annex D (Normative) Items subject to agreement between manufacturer and user 139 Annex E Void... 140 Annex F (Normative) Requirements for auxiliary contact linked with power contact (mirror contact)... 141 Annex G (Informative) Rated operational currents and rated operational powers of switching devices for electrical motors... 144 Annex H (Normative) Extended functions to electronic overload relays... 149 Annex I (Informative) AC-1 contactors for use with semiconductor controlled motor load... 151 Annex J Void... 152 Annex K (Normative) Procedure to determine data for electromechanical contactors used in functional safety applications... 153 Annex L (Normative) Assessment procedure for electromechanical overload protection device used in safety applications and especially in explosive atmospheres... 155 Annex M (Normative) DC contactors for use in photovoltaic (PV) applications... 171 Annex N (Normative) Additional requirements and tests for equipment with protective separation... 180 Annex O (Informative) Load monitoring... 183 Annex P (Normative) Short-circuit breaking tests of MPSD... 188 Annex Q (Normative) Co-ordination under short-circuit conditions between a MPSD and another short-circuit protective device associated in the same circuit... 195 Bibliography... 204

Foreword

GB/T 14048 "Low-voltage switchgear and controlgear" consists of the following parts. - Part 1.General rules; - Part 2.Circuit-breakers; - Part 3.Switches, disconnectors, switch-disconnectors and fuse-combination units; - Part 4-1.Contactors and motor-starters - Electromechanical contactors and motor- starters (Including motor protector); - Part 4-2.Contactors and motor-starters - AC semiconductor motor controllers and starters (including soft-starters); - Part 4-3.Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads; - Part 5-1.Control circuit devices and switching element - Electromechanical control circuit devices; - Part 5-2.Control circuit appliances and switching elements - Proximity switches; - Part 5-3.Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB); - Part 5-4.Control circuit devices and switching elements - Method of assessing the performance of low-energy contacts - Special tests; - Part 5-5.Control circuit devices and switching elements - Electrical emergency stop device with mechanical latching function; - Part 5-6.Control circuit devices and switching elements - DC interface for proximity sensors and switching amplifiers (NAMUR); - Part 5-7.Control circuit devices and switching elements - Requirements for proximity devices with analogue output; - Part 5-8.Control circuit devices and switching elements - Three-position enabling switches; - Part 5-9.Control circuit devices and switching elements - Flow rate switches; - Part 6-1.Multiple function equipment - Transfer switching equipment; - Section 6-2.Multiple function equipment control and protective switching devices (or equipment) (CPS); - Part 7-1.Ancillary equipment - Terminal blocks for copper conductors; - Part 7-2.Ancillary equipment - Protective conductor terminal blocks for copper conductors; - Part 7-3.Ancillary equipment - Safety requirements for fuse terminal blocks; - Part 7-4.Ancillary equipment - PCB terminal blocks for copper conductors; - Part 8.Control units for built-in thermal protection (PTC) for rotating electrical machines. This Part is Part 4-1 of GB/T 14048. This Part is drafted in accordance with the rules given in GB/T 1.1-2009. This Part replaces GB/T 14048.4-2010 "Low-voltage switchgear and control gear - Part 4-1.Contactors and motor-starters - Electromechanical contactors and motor-starters (Including motor protector)". Compared with GB/T 14048.4-2010, the main technical changes in this Part are as follows. - Modify the definition of reversing starter. - Add relevant requirements and tests for motor protective switching device MPSD. - Add some requirements concerning safety aspects, including.  General;  Circuits sourced from limited energy sources;  Electronic circuits;  Assessment procedure for electromechanical overload protection device used in safety applications (see Annex L). - In order to adapt to the use conditions of motors with higher energy efficiency, add the relevant regulations for high locked rotor current. - Add requirements for special wiring accessories. - Add measurement of pick-up power consumption. - Be consistent with the latest content of IEC 60947-1A2.2014. - Add relevant DC requirements for PV applications (see Annex M). - Add the content of load monitoring (see Annex O). - Add the co-ordination under short-circuit conditions between a MPSD and another short-circuit protective device in the same circuit (see Annex Q). - Delete the previous Annex J - Communication function of electronic overload relay. This Part uses the redraft law to modify and adopt IEC 60947-4-1.2018 "Low-voltage switchgear and controlgear - Part 4-1.Contactors and motor-starters - Electromechanical contactors and motor-starters". The technical differences between this Part and IEC 60947-4-1.2018 and their reasons are as follows. - As for the normative references, this Part has made adjustments with technical differences, to adapt to the technical conditions of China. The adjustments are mainly reflected in Clause 2 “Normative references”. The specific adjustments are as follows.  Replace IEC 60034-1.2017 with GB/T 755-2019 which is identical to the international standard;  Replace IEC 60034-12.2016 with GB/T 21210-2016 which is identical to the international standard;  Replace IEC 60034-30-1 with GB/T 32891.1 which is identical to the international standard;  Replace IEC 60038 with GB/T 156 which modifies and adopts the international standard;  Replace IEC 60068-2-14.2009 with GB/T 2423.22-2012 which is identical to the international standard;  Replace IEC 60079-14 with GB/T 3836.15-2017 which modifies and adopts the international standard;  Replace IEC 60085.2007 with GB/T 11021-2014 which is identical to the international standard;  Replace IEC 60364-1.2005 with GB/T 16895.1-2008 which is identical to the international standard;  Replace IEC 60364-7-712 with GB/T 16895.32 which is identical to the international standard;  Replace IEC 60730-1 with GB/T 14536.1 which is identical to the international standard;  Replace IEC 60947-1.2007+AMD1.2010 with GB/T 14048.1-2012 which modifies and adopts the international standard;  Replace IEC 60947-2.2019 with GB/T 14048.2-2020 which modifies and adopts the international standard;  Replace IEC 60947-5-1.2016 with GB/T 14048.5-2017 which modifies and adopts the international standard;  Replace IEC 61051-2 with GB/T 10194 which is identical to the international standard;  Replace IEC 61140.2016 with GB/T 17045-2008 which is identical to the international standard;  Replace IEC 61810-1 with GB/T 21711.1-2008 which is identical to the international standard;  Replace ISO 2859-1.1999 with GB/T 2828.1-2012 which is identical to the international standard;  Replace ISO 3864-2 with GB/T 2893.2 which modifies and adopts the international standard;  Add reference to GB/T 2423.2-2008;  Add reference to GB/T 3956-2008;  Add reference to GB/T 14048.3-2017;  Add reference to GB 21518. - Electrical equipment with an AC rated voltage of 1140 V may refer to this Part. The requirements such as performance of the relevant electrical equipment shall be determined through negotiation between the manufacturer and the user. - According to the provisions of GB/T 156-2017, in 5.3.1.1.1, change "230/400 V or 400 V (50 Hz)" to "220/380 V or 380 V (50 Hz)"; delete the example of 277/480 V or 480 V (60 Hz). - According to the latest revision of GB 21518, modify the method of power consumption measurement. - In Table 11, specify the minimum test current of 5040 A for products above 630 A that meet the AC-3e utilization category. - Consistent with the provisions of 8.3.1, delete the contents of 9.4.2.7 and 9.4.2.8. The following editorial changes have been made to this Part. In order to be consistent with China's standard system, change the standard name to "Low-voltage switchgear and controlgear - Part 4-1.Contactors and motor-starters - Electromechanical contactors and motor-starters (Including motor protector)"; - Delete index of terms and definitions. - After analyzing the modification content of IEC 60947.2007/A2.2014, since there is no difference in technical content, DELETE the reference to IEC 60947.2007/A2.2014 BY 5.5, 6.3, Clause 7, 8.1.2.1, 8.2.2.9, 8.2.3.2, 9.1.2, 9.3.2, 9.3.3.2.1.1, 9.3.3.2.2, 9.4.1, H.1, M.7.1, M.9.8, P.3.2, P.4.2, and Q.1.After respectively incorporating the technical revisions of IEC 60947.2007/A2.2014 into the corresponding subclauses, DELETE the reference to IEC 60947.2007/A2.2014 BY 8.1.2.2, 8.1.4, 8.2.2.6, 8.2.5.3.2, 8.3.3, 9.2.1, 9.3.3.3.1, 9.3.3.4.1, 9.3.4.2.4, and Annex N. - Modify the SCPD test requirements in 8.2.5.1 (see 9.3.4.2.2 and 9.3.4.2.3). - Add 8.3.3.1 “General” and adjust the numbering of the subsequent two subclauses. - Modify the reference "4.2 and 4.3" of IEC 61140.2016 in N.3.1 TO "4.1 and 4.2" of GB/T 17045-2008. This Part was proposed by China Electrical Equipment Industry Association. This Part shall be under the jurisdiction of National Technical Committee 189 on Low- voltage Apparatus of Standardization Administration of China (SAC/TC 189). Drafting organizations of this Part. Shanghai Electrical Apparatus Research Institute; Zhejiang CHINT Electrics Co., Ltd.; Changshu Switchgear MFG. Co., Ltd. (Former Changshu Switchgear Plant); Shanghai Branch of Schneider Electric (China) Co., Ltd.; Shanghai Liangxin Electrical Co., Ltd.; Zhejiang Tengen Electric Co., Ltd.; Delixi Electric Co., Ltd.; Siemens Electrical Apparatus Ltd., Suzhou; Shanghai Renmin Electrical Apparatus Works, Shanghai Electric; Changan Group Co., Ltd.; Huanyu High-Tech Co., Ltd.; NOARK Electric (Shanghai) Co., Ltd.; Zhejiang People Electric Appliance Co., Ltd.; Suzhou Wanlong Electric Group Co., Ltd.; Zhaozheng Electric Co., Ltd.; Shanghai Nesfel Electric Co., Ltd. Main drafters of this Part. Li Hui, Zheng Jiexin, Xiao Tifeng, Gu Yiwen, Zhang Dongjin, Xie Qiangqiang, Jin Haifu, Li Xinye, Zhu Lin, Le Ying, Wang Xuchuan, Pan Ruxin, Wang Haiyuan, Bao Zhizhou, Cheng Yubiao, Zhang Qijian, Wu Manhuai. The previous editions of the standard replaced by this Part were released as follows. - GB 14048.4-1993, GB 14048.4-2003, GB/T 14048.4-2010.

1 Scope

This Part of GB/T 14048 specifies.

2 Normative references

The following documents are indispensable for the application of this document. For the dated references, only the editions with the dates indicated are applicable to this document. For the undated references, the latest edition (including all the amendments) are applicable to this document. GB/T 156 Standard voltages (GB/T 156-2017, IEC 60038.2009, MOD) GB/T 755-2019 Rotating electrical machines - Rating and performance (IEC 60034- 1.2017, IDT)

3 Terms, definitions, symbols and abbreviated terms

Contactor in which the force for closing the open main contacts or opening the closed main contacts is provided by a device using compressed air, without the use of electrical means.

4 Classification

gives all the types and kinds which may be used as criteria for classification.

5 Characteristics of contactors and starters

For rheostatic rotor starters, the value of rated rotor operational voltage is that of the voltage which, when combined with a rated rotor operational current, determines the application of the rotor circuit including its mechanical switching devices and to which are referred the making and breaking capacities, the type of duty and the starting characteristics.

6 Product information

Additional information for the decommissioning and dismantling of the device shall be maintained available to the user in case of foreseeable hazardous condition of the device, for example due to stored energy, instability or falling of objects, etc. In the case of protected starters, the manufacturer shall also provide the necessary mounting and wiring instructions.

7 Normal service, mounting and transport conditions

Rail mounting shall be specified according to IEC 60715.2017, when relevant. Standard conditions of vibration are defined in footnote b of Annex Q of GB/T 14048.1- 2012.

8 Constructional and performance requirements

Components used in the construction of the equipment, compliant with a relevant product standard do not require separate evaluation. Components or assemblies of components, for which no relevant product standard exists, shall be tested according to the requirements of this Part.

9 Tests

For the low temperature test, the test Ad is to be chosen instead of the test Ab and the contactor shall be in the open position during the cooling period. It shall then be energized for the last hour. ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of GB/T 14048.4-2020 be delivered?Answer: The full copy PDF of English version of GB/T 14048.4-2020 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 14048.4-2020_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 14048.4-2020_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 14048.4-2020 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB/T 14048.4-2020?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14048.4-2020 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB/T 14048.4-2020?

A step-by-step guide to download PDF of GB/T 14048.4-2020_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 14048.4-2020".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9