Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 13380-2018 English PDF

US$679.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 13380-2018: A.C. electric fans and regulators
Status: Valid

GB/T 13380: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 13380-2018679 Add to Cart 5 days A.C. electric fans and regulators Valid
GB/T 13380-2007999 Add to Cart 6 days A.C. electric fans and regulators Obsolete
GB/T 13380-1992839 Add to Cart 6 days A. C. electric fans and regulators Obsolete

Similar standards

GB/T 4343.2   GB/T 3883.311   JB/T 10772   GB/T 32517   GB/T 19215.5   

Basic data

Standard ID: GB/T 13380-2018 (GB/T13380-2018)
Description (Translated English): A.C. electric fans and regulators
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K65
Classification of International Standard: 23.120
Word Count Estimation: 34,377
Date of Issue: 2018-12-28
Date of Implementation: 2019-07-01
Older Standard (superseded by this standard): GB/T 13380-2007
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 13380-2018: A.C. electric fans and regulators

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ACelectric fans and regulators ICS 23.120 K65 National Standards of People's Republic of China Replace GB/T 13380-2007 AC fan and governor (IEC 60879.1986, Performance and construction of electric Published on.2018-12-28 2019-07-01 implementation State market supervision and administration China National Standardization Administration issued

Content

Foreword III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 2 4 Product Category 3 5 Technical requirements 4 6 Test method 8 7 Inspection rules 17 8 Marking, packaging, transportation, storage 20 Appendix A (Normative Appendix) Calculation of air volume for table fans, wall fans, floor fans, landing fans, page fans, and ceiling fans 22 Appendix B (Normative Appendix) Calculation of air volume for ceiling fans and decorative ceiling fans 23 Appendix C (Normative Appendix) Column Fan Air Performance Test Method 24

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB/T 13380-2007 "AC fan and governor". This standard is compared with GB/T 13380-2007, mainly The technical changes are as follows. --- Write the nine "terms" in Appendix C of GB/T 13380-2007 into the definition of Chapter 3 (see Chapter 3); ---Based on air volume test method and verification data, for table fans, wall fans, floor fans, floor fans, ceiling fans, and page turning of 300mm and below The fan's air volume has been adjusted appropriately. The air volume value of 230mm and below is assessed according to the requirements of non-preferred size, ie Self-calibrated by the manufacturer (see 5.2); --- The energy efficiency value of table fans, wall fans, floor fans, floor fans, ceiling fans and turning fans of 300mm and below is based on the verification data. When the adjustment. The energy efficiency values of 230mm and below are evaluated according to the requirements of non-preferred sizes (see 5.3); --- The energy efficiency value of the column fan is adjusted according to the test method and verification data (see 5.3); --- According to the development and changes of column fan product specifications, the noise limit is changed from the original 50dB (A) to 63dB (A) (see 5.5); ---Air volume test of table fan, wall fan, table fan, floor fan, ceiling fan and turning fan, from original table fan, wall fan, table fan, top fan and page turning The fan is tested in a 4.5m long test room, and the floor fan is allowed to be tested in a 6m long air volume (400mm floor fan is allowed) Air flow test in a 4.5m long test room), changed to. electric fan less than or equal to 400mm (table fan, wall fan, platform) Fans, floor fans, ceiling fans, and turning fans are tested in a 4.5 m long test chamber, and the above-mentioned electric fans are larger than 400 mm. Air volume test at 6 m long air volume test (see 6.7.1); --- Increased wet heat test of organic coated parts. The test temperature and humidity conditions are. temperature, (40 ± 2) ° C; relative humidity, (93 ± 3)% (see 6.13); --- Table fan, wall fan, table fan, floor fan, ceiling fan and page fan wind speed measurement method, from the original horizontal direction 2 tables to water Test the wind speed in two tables (four in total) in the horizontal and vertical directions (to increase the uniformity of the average wind speed of the ring) (see 6.7.1.1); --- The air volume test of the column fan was changed to the air volume test method of GB/T 1236 (see 6.7.3); --- The "leakage current and electric strength test" project of the factory inspection was changed to "electrical strength test" and "input power and current" items were changed to “Input power measurement” adds “simplified method used in factory inspection” (see Table 6 of 7.2.1); --- Type testing adds "radiation, toxicity and similar hazards" to the project, adding Note 4 to Table 7 (see Table 7 of 7.3.2); --- Added Appendix C "Air Performance Test Method for Column Fans". This standard uses the redrafting method to refer to IEC 60879.1986 "Structure and Performance of Circulating Fans and Their Governors" and its.1992 survey The degree of consistency with IEC 60879.1986 is not equivalent. This standard was proposed by the China Light Industry Association. This standard is under the jurisdiction of the National Standardization Technical Committee for Household Appliances (SAC/TC46). This standard was drafted. China Electric Apparatus Research Institute Co., Ltd., Guangdong Midea Environmental Electric Appliance Manufacturing Co., Ltd., Zhuhai Gree Electric Appliance Co., Ltd., Emmett Electric (Shenzhen) Co., Ltd., Weikai Testing Technology Co., Ltd., Foshan Quality Measurement Supervision and Inspection Center, Jiang Men's Jinling Fan Manufacturing Co., Ltd., Ningbo Pioneer Electric Manufacturing Co., Ltd., Qingdao Haier Complete Appliances Service Co., Ltd., Foshan City Jixing Home Appliances Co., Ltd., Jiangmen Jinling Fan Manufacturing Co., Ltd., Foshan Nanhai Electric Fan Industry Association, Guangdong Zhengye Electric Co., Ltd. the company. The main drafters of this standard. Chen Hangui, Liu Yanping, Chen Jin, Luo Lizhen, Ou Zhuohong, Liu Xiang, Yao Yuchu, Li Jian, Huang Min, Zhao Jianjiang, Huang Huizhen, Wu Lijuan, Liu Hongtao, Chen Jiang, Chen Qicai, Yang Yuda, Wu Wei, Liang Jianzhong, Zhu Yongguo, Tan Jinjian. The previous versions of the standards replaced by this standard are. ---GB n158-1982, GB/T 13380-1992, GB/T 13380-2007. AC fan and governor

1 Scope

This standard specifies the product classification, technical requirements, test methods, inspection rules, marking, packaging, transportation and communication of AC fans and governors. Storage. This standard applies to single-phase rated voltage not exceeding 250V, other rated voltage does not exceed 480V, the table fan driven by AC motor, Wall fans, floor fans, floor fans, ceiling fans, ceiling fans, page fans, column fans and decorative ceiling fans and their governors. This standard does not apply to electric fans used under other special conditions.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 191 packaging storage and transportation pictorial signs (GB/T 191-2008, ISO 780.1997, MOD) GB/T 1002 Household and similar single-phase plug and socket type, basic parameters and dimensions GB/T 1003 Household and similar three-phase plug and socket type, basic parameters and dimensions GB/T 1019-2008 General rules for the packaging of household and similar electrical appliances GB/T 1236-2017 Industrial ventilators for performance testing with standardized air ducts (ISO 5801.2007, IDT) GB/T 2099.1 Household and similar plugs and sockets - Part 1. General requirements (GB/T 2099.1-2008, IEC 60884- 1.2006, MOD) GB/T 2423.3 Environmental Test Part 2. Test Methods Test Cab. Constant Damp Heat Test (GB/T 2423.3-2006, IEC 60068-2-78.2001, IDT) GB/T 2423.17 Basic environmental test procedures for electric and electronic products test Ka. salt spray test method (GB/T 2423.17- 2008, IEC 60068-2-11. 1981, IDT) GB/T 2828.1-2012. Sampling procedures for sampling by sampling - Part 1 . Batch-by-batch inspections by Retrieving Quality of Acceptance (AQL) Sample plan (ISO 2859-1.1999, IDT) GB/T 2829-2002 Periodic inspection count sampling procedures and tables (applicable to the inspection of process stability) GB/T 2900.29 Electrical terminology for household and similar electrical appliances GB/T 3667.1 AC motor capacitors - Part 1. General performance, test and s Guidelines (GB/T 3667.1-2016, IEC 60252-1.2013, IDT) GB/T 3667.2 AC motor capacitors Part 2. Motor starting capacitors (GB/T 3667.2-2016, IEC 60252-2.2013, IDT) GB/T 4214.1-2017 - Test methods for noise of household appliances and similar appliances - Part 1 . General requirements (IEC 60704-1.2010, MOD) GB 4343.1 Electromagnetic compatibility requirements for household appliances, power tools and similar appliances - Part 1 . Launching (GB 4343.1-2009, CISPR14-1..2005, IDT) Safety of household and similar electrical appliances - Part 1. General requirements (GB 4706.1-2005, IEC 60335-1. 2004, IDT) Safety of household and similar electrical appliances - Part 2. Particular requirements for fans (IEC 60335-2-80.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 13380-2018_English be delivered?

Answer: Upon your order, we will start to translate GB/T 13380-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 13380-2018_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 13380-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 13380-2018?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13380-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.