GB/T 11066.2-2008 English PDFUS$139.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 11066.2-2008: Methods for chemical analysis of gold -- Determination of silver content -- Flame atomic absorption spectrometry Status: Valid GB/T 11066.2: Historical versions
Basic dataStandard ID: GB/T 11066.2-2008 (GB/T11066.2-2008)Description (Translated English): Methods for chemical analysis of gold -- Determination of silver content -- Flame atomic absorption spectrometry Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: H68 Classification of International Standard: 77.150.99 Word Count Estimation: 6,632 Date of Issue: 2008-06-09 Date of Implementation: 2008-12-01 Older Standard (superseded by this standard): GB/T 11066.2-1989 Regulation (derived from): National Standard Approval Announcement 2008 No.9 (Total No.122) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the method for the determination of gold in silver content. This section applies to the determination of gold in silver content. Measurement range: 0. 0005% 0. 0400%. GB/T 11066.2-2008: Methods for chemical analysis of gold -- Determination of silver content -- Flame atomic absorption spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of gold. Determination of silver content. Flame atomic absorption spectrometry ICS 77.150.99 H68 National Standards of People's Republic of China Replacing GB/T 11066.2-1989 Methods for chemical analysis of gold Silver content - Flame Atomic Absorption Spectrometry Posted 2008-06-09 2008-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordGB/T 11066 "Methods for chemical analysis of gold" is divided into the following 10 sections. --- GB/T 11066.1 gold chemical analysis method of determining the amount of gold fire assay; --- GB/T 11066.2 gold chemical analysis of silver content - Flame atomic absorption spectrometry; --- GB/T 11066.3 gold chemical analysis of iron content by flame atomic absorption spectrometry; --- Flame atomic GB/T 11066.4 gold chemical analysis of copper, lead and bismuth contents absorption spectrometry; --- GB/T 11066.5 gold chemical analysis method for determination of atomic silver, copper, iron, lead, antimony and bismuth amount of emission spectrometry; --- Flame atomic GB/T 11066.6 gold chemical analysis of iron, nickel, manganese, and palladium absorption spectrometry; --- GB/T 11066.7 gold chemical analysis of silver, copper, iron, lead, antimony, bismuth, palladium, magnesium, tin, nickel, manganese and chromium contents - fire Flower atomic emission spectrometry; --- GB/T 11066.8 gold chemical analysis of silver, copper, iron, lead, antimony, bismuth, palladium, magnesium, nickel, manganese and chromium contents - ethyl acetate Ester extraction -ICP-AES method; --- GB/T 11066.9 gold chemical analysis method for determination of arsenic and tin hydride - atomic fluorescence spectrometry; --- GB/T 11066.10 chemical analysis of gold - Determination of silicon content of silicon molybdenum blue spectrophotometric method. This is Part 2. This Part replaces GB/T 11066.2-1989 "gold chemical analysis by flame atomic absorption spectrometry spectra of silver." versus GB/T 11066.2-1989 compared to the main changes are as follows. --- Sensitivity of the instrument will be requirements to characteristic concentration; --- Remove the allowable difference, increasing the precision; --- Increased quality assurance and control chapter. This part is proposed by the China Nonferrous Metals Industry Association. The non-ferrous metal part by the National Standardization Technical Committee. This section is responsible for drafting unit. Chengdu Banknote Printing Company. This section is drafted. Beijing Mining Research Institute, Chengdu Banknote Printing Company. Participated in the drafting of this section. Shanghai Mint, Shenyang Mint Institute of Technology, Jiangxi Copper Company, Zijin Copper Group, Hubei Daye Nonferrous Metals Group, and the National Gold and Silver Products Quality Supervision and Inspection Center. The main drafters of this section. Fu Bin Nguyen Cinnamon, Lihua Chang, Chen Jie, Wang Zisen, Ma Yuqin, Liu Feng. This part certifier. Wang Haoying, Yindong Xia. This part of the standard replaces the previous editions are. --- GB/T 11066.2-1989. Methods for chemical analysis of gold Silver content - Flame Atomic Absorption Spectrometry1 ScopeThis section provides the determination of gold in silver content. This section applies to the determination of gold in silver content. Measurement range. 0.0005% - 0.0400%.2 Method summarySample decomposition with aqua regia, in 3mol/L HCl medium, after separation of gold extracted with ethyl acetate, the aqueous phase is concentrated into hydrochloric acid (1 + 9) to be Test solution, using air - acetylene flame atomic absorption spectrometer the absorbance was measured at a wavelength of 328.1nm silver.3 ReagentsUnless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. 3.1 hydrochloric acid (ρ about 1.19g/mL), pure class distinctions. 3.2 HCl (1 + 1). Hydrochloride 3.3 (1 + 9). 3.4 hydrochloride (Ba (HCl) = 3mol/L). 3.5 nitric acid (ρ about 1.42g/mL), pure class distinctions. 3.6 nitric acid (1 + 1). Dilute aqua regia 3.7. 1 to 3 parts of nitric acid and hydrochloric acid and 3 parts of water and mix. 3.8 ethyl acetate. 3.9 silver standard stock solution. Weigh 0.1000g metallic silver (mass fraction ≥99.95%), low-temperature heating was dissolved in 10mL of nitric acid (3.6) Was added 30mL ~ 40mL of hydrochloric acid (3.1), heated to boiling until the precipitate is completely dissolved, cool to room temperature. Moved into 1000mL volumetric flask Hydrochloric acid (3.2) diluted to the mark, and mix. This solution 1mL containing 100μg silver. 3.10 Silver standard solution. Pipette 25.00mL silver standard stock solution (3.9) in 200mL volumetric flask, dilute to the mark with hydrochloric acid (3.3) Degree, and mix. This solution 1mL containing 12.5μg silver.4 InstrumentAtomic absorption spectrometer, with a silver hollow-cathode lamp. Under optimum working conditions for those who can reach the following indicators can be used. --- Characteristic mass concentration. In line with the measurement of a sample solution matrix solution features quality silver concentration should not exceed 0.033μg/mL. --- Linear curve. the mass concentration curve divided into five sections, the difference between the absorbance difference between the highest and the lowest absorbance segment segment The ratio shall be not less than 0.85. --- Precision. measuring the absorbance of the standard solution 10 times the highest concentration of the standard deviation should not exceed the average absorbance 1%; absorbance measured 10 times the minimum concentration of the standard solution (not a "zero" standard solution), and the standard deviation should not exceed 0.5% of the highest average concentration of the standard solution absorbance. --- Recommended for P-E1100 atomic absorption spectrometer operating conditions refer to silver as shown in Table 1. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 11066.2-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 11066.2-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 11066.2-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 11066.2-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 11066.2-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 11066.2-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |