GB/T 11066.1-2008 English PDFUS$139.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 11066.1-2008: Methods for chemical analysis of gold -- Determination of gold content -- Fire assaying method Status: Valid GB/T 11066.1: Historical versions
Basic dataStandard ID: GB/T 11066.1-2008 (GB/T11066.1-2008)Description (Translated English): Methods for chemical analysis of gold -- Determination of gold content -- Fire assaying method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: H68 Classification of International Standard: 77.150.99 Word Count Estimation: 6,664 Date of Issue: 2008-06-09 Date of Implementation: 2008-12-01 Older Standard (superseded by this standard): GB/T 11066.1-1989 Regulation (derived from): National Standard Approval Announcement 2008 No.9 (Total No.122) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the method for the determination of gold in the gold content. This section applies to the determination of gold in the gold content. Measuring range: 99. 50% to 99. 95%. GB/T 11066.1-2008: Methods for chemical analysis of gold -- Determination of gold content -- Fire assaying method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of gold.Determination of gold content.Fire assaying method ICS 77.150.99 H68 National Standards of People's Republic of China Replacing GB/T 11066.1-1989 Methods for chemical analysis of gold Determination of the amount of gold fire assay Posted 2008-06-09 2008-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordGB/T 11066 "Methods for chemical analysis of gold" is divided into 10 sections as follows. --- GB/T 11066.1 gold chemical analysis method of determining the amount of gold fire assay; --- GB/T 11066.2 gold chemical analysis of silver content - Flame atomic absorption spectrometry; --- GB/T 11066.3 gold chemical analysis of iron content by flame atomic absorption spectrometry; --- Flame atomic GB/T 11066.4 gold chemical analysis of copper, lead and bismuth contents absorption spectrometry; --- GB/T 11066.5 gold chemical analysis method for determination of atomic silver, copper, iron, lead, antimony and bismuth amount of emission spectrometry; --- GB/T 11066.6 gold chemical analysis of magnesium, nickel, manganese, and palladium contents - Flame atomic absorption spectrometry; --- GB/T 11066.7 gold chemical analysis of silver, copper, iron, lead, antimony, bismuth, palladium, magnesium, tin, nickel, manganese and chromium contents - fire Flower atomic emission spectrometry; --- GB/T 11066.8 gold chemical analysis of silver, copper, iron, lead, bismuth, antimony, palladium, magnesium, nickel, manganese and chromium contents - ethyl acetate Ester extraction -ICP-AES method; --- GB/T 11066.9 gold chemical analysis method for determination of arsenic and tin hydride - atomic fluorescence spectrometry; --- GB/T 11066.10 Determination of gold chemical analysis of silicon content - Molybdenum blue spectrophotometric method. This is Part 1. This Part replaces GB/T 11066.1-1989 "Methods for chemical analysis of gold fire assay determination of gold." This portion GB/T 11066.1-1989 compared to the main changes are as follows. --- The cupel material produced by the "pure ashes made" with "pure magnesia ashes or made"; --- Increased provision sample; --- The sampling amount "Weigh 1.00000g sample" to "Weigh 0.50 or 1.00g sample" from "each test sample and standard materials 2.5g silver "to" gold standard per test materials plus 1.25g or 2.5g Silver "; --- Will grind tablets "from the ends of the film roll to the line into two identical cylinders' contents, changed to" the annealed sheet rolled into a round gold and silver Cylindrical "; --- Third Parting added "when the sample amount is 1.00g was weighed when, for the third sub-gold"; --- In the "results of the analysis to calculate the" Terms restatement is calculated and the result unit and adds the results to the decimal representation After the contents of the median point; --- Instead of using precision allowable difference; --- Increased quality assurance and control provisions. This part is proposed by the China Nonferrous Metals Industry Association. The non-ferrous metal part by the National Standardization Technical Committee. This section is responsible for drafting the Chengdu Banknote Printing Company. This part by the Chengdu Banknote Printing Company, Shenyang Mint, the National Gold and Silver Products Quality Supervision and Inspection Center and drafting. This in part by the Shanghai Mint, Beijing Mining Research Institute participated in the drafting. The main drafters of this section. Wang Zisen, Chen Jie, Lai Maoming, Wang Yu, Zhang Bo, Huang Rui, Chen Feifei, Lihua Chang, Fu Bin, in force, Mu Hua, Bo, Bo Meng, Shi Xue pure Wei Lingzhi, Guode Qian. This part certifier. Dupei Yong, Tian boiling, He Qingping, Zhang Mei, Zhuxiu Fen, Huang Minhua. This part of the standard replaces the previous editions are. --- GB/T 11066.1-1989. Methods for chemical analysis of gold Determination of the amount of gold fire assay1 ScopeThis section provides the determination of gold content in gold. This section applies to the determination of gold in gold content. Measurement range. 99.50% to 99.95%.2 Method summarySample adding an appropriate amount of silver, wrapped in lead foil, make the ash blowing at 920 ℃, and impurities of lead oxide and gold and silver separation, gold and silver alloy particles stay In the gray dish. The gold and silver alloy particles made of an alloy by volume nitric acid points gold weighed, dried along with measured gold standard correction calculation sample The gold content.3 Reagents and materialsUnless otherwise indicated, used in the analysis is only confirmed analytically pure reagent, such as distilled water, deionized water or equivalent purity. 3.1 .( pure lead foil lead, Pb mass fraction of not less than 99.99%), crushed 0.1mm thin, cut into squares, each weighing about 3g. 3.2 Silver. (Ag, mass fraction of not less than 99.99%). 3.3 nitric acid (1 + 1). 3.4 nitric acid (1 + 2). 3.5 gold standard (gold content of not less than 99.98%).4 instruments and appliances4.1 box-type high-temperature furnace. 4.2 Balance. a sense of the amount of 0.01mg. 4.3 mill machine. can grind thickness of 0.1mm. 4.4 Golden Basket. made of 0.5mm ~ 1.0mm stainless steel sheet (or platinum mesh). 4.5 cupel. pure ashes or made of magnesia, size × h. 30mm × 20mm, the concave depth of 10mm. 4.6 long-handled pliers cupel.5 SampleTo avoid contamination of the surface of the specimen, can be used (1 + 1) hydrochloric heat soak 15min. Washed by the water after washing with alcohol or acetone twice, Drying in the oven at 105 ℃ ~ 110 ℃. Step 6 Analysis 6.1 Sample Weigh 0.50g or 1.00g sample to the nearest 0.00001g; Weigh (3.5) 4 parts and in a sample of similar quality gold gold standard, Accurate to 0.00001g. Each gold standard test materials plus 1.25g or 2.5g Silver (3.2), including a ball with two lead foil (3.1). 6.2 Determination of the number of Independently measured three times and averaged. 6.3 cupellation Cupel (4.5) at about 950 ℃ preheating 20min, which has been wrapped sample (6.1) and standard (6.1) are arranged in the order cross into good ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 11066.1-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 11066.1-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 11066.1-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 11066.1-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 11066.1-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 11066.1-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |