GB 10235-2012 English PDF

US$339.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 10235-2012: [GB/T 10235-2012] Hazard reducing device for arc welding power source
Status: Valid

GB 10235: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 10235-2012339 Add to Cart 3 days [GB/T 10235-2012] Hazard reducing device for arc welding power source Valid
GB 10235-2000599 Add to Cart 4 days Arc welding transformer hazard reducing device Obsolete
GB/T 10235-1988RFQ ASK 3 days Arc welding transformer against electric shock device Obsolete

Similar standards

GB/T 41861   GB/T 40337   GB/T 35091   GB/T 15579.1   GB/T 15579.7   GB/T 15579.5   

Basic data

Standard ID: GB 10235-2012 (GB10235-2012)
Description (Translated English): [GB/T 10235-2012] Hazard reducing device for arc welding power source
Sector / Industry: National Standard
Classification of Chinese Standard: J64
Classification of International Standard: 25.160.30
Word Count Estimation: 13,172
Older Standard (superseded by this standard): GB 10235-2000
Quoted Standard: GB/T 2423.3; GB/T 2900.22; GB 4208; GB/T 5169.10; GB/T 5169.11; GB/T 15579.1
Regulation (derived from): National Standards Bulletin No. 41 of 2012
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Chinese standard specifies the welding power source electric shock devices products Types, basic parameters, structural and safety requirements, test methods, inspection rules and nameplate information. This standard applies to GB 15579. 1 provided f

GB 10235-2012: [GB/T 10235-2012] Hazard reducing device for arc welding power source

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Hazard reducing device for arc welding power source ICS 25.160.30 J64 National Standards of People's Republic of China Replacing GB 10235-2000 Welding power source electric shock devices Issued on. 2012-12-31 2013-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Product Types and basic parameters 2 Conditions 5 2 6 Installation Conditions 2 7 Structure and safety requirements 2 8 6 test methods 8 9 inspection rules 10 Nameplate 9 Table 1 delay time 3 Table 2 terminals can be connected conductor nominal cross-sectional area of 4 Table 3 limits of temperature rise 5 Table 4 glow-wire tip temperature and test time 7 Table 5 routine test items 9

Foreword

The standard Chapter 3 "Terms and definitions" are recommended, the rest are mandatory. This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB 10235-2000 "welding transformer electric shock devices." This standard compared with GB 10235-2000 major changes as follows. --- Standard names arc welding power transformer to change. --- Expanding the scope of the standard, the original standard applies only to single-phase power supply. --- A reference to the standard has been updated. --- The definition made some deleted or modified. --- Increase the rated duty cycle rating, terminals can be connected to the wire nominal cross-sectional area and the range of terminals Protection Requirements, increasing the temperature rise limits of power devices. --- On the conditions of use, time delay, starting resistor values and test methods, the dielectric strength test voltage, shell protection grade, normal Requirements, fault protection requirements of work instructions, drop test method, routine test items have been modified. --- Cancel the provisions of the preparation and control products in the form of model provisions. --- Canceled the electrode touches the workpiece a predetermined time, the electromagnetic contactor is, anti-jamming performance, capacity and complete sets of continuous action Claim. --- Cancel the packaging, transportation and storage requirements. The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Standardization Technical Committee Welder (SAC/TC70) centralized. This standard was drafted. Nantong thirty-nine welding machines Manufacturing Co., Ltd., Beijing Sanjiang Electrical Equipment Factory, Zhejiang Kende Electromechanical shares have Limited Shenzhen Ruiling Industrial Co., Ltd., Wuxi Hanshin Electric Co., Ltd., Chengdu tripartite Electric Co., Ltd., Foshan City, Grand electricity Gas Co., Ltd., Chengdu Electric and Inspection. The main drafters of this standard. Wang Xiaojian, Meng Xiangyi, Zhuxuan Hui, Qiu light, He Xiaoyang, Yangqing Xuan, Rong Xi, Xing Jun. This standard replaces the standards previously issued as follows. --- GB 12350-1988, GB 12350-2000. Welding power source electric shock devices

1 Scope

This standard specifies the product type welding power source electric shock devices, the basic parameters, structural and safety requirements, test methods, inspection rules and Nameplate information. This standard applies to GB 15579.1 under the various types of arc welding power source with electric shock devices (hereinafter referred to as the device).

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2423.3 Environmental testing for electric and electronic products Part 2. Test methods - Test Cab. Damp heat test GB/T 2900.22 Electrotechnical terminology Welder GB 4208 housing protection (IP Code) GB/T 5169.10 Fire hazard testing for electric and electronic products - Part 10. Glowing/hot wire based test methods - Glow wire mounted General methods of test and set GB/T 5169.11 Fire hazard testing for electric and electronic products - Part 11. Glowing/hot wire based test methods for finished burning Hot wire flammability test method GB 15579.1 welding equipment - Part 1. Welding power

3 Terms and Definitions

GB/T 2900.22, GB 15579.1 define the following terms and definitions apply to this document. 3.1 Operation Resistance actingresistance The maximum resistance value of the device operation of welding power output circuit. 3.2 Starting time operatingtime Contact with the workpiece from the electrode to the welding power reaches the rated load voltage. 3.3 Delay time delayingtime Rated load voltage generated from the welding power source to the load voltage down to low altitude of time. 3.4 Built-in units innerdevice Mounted within the housing arc welding power source, and a device sold separately. This device may be a separate housing, it can also be outside the arc welding power source Shell cater to the housing unit. 3.5 Outside-mounted device outerdevice Mounted on the welding power external devices. 3.6 Cabinet-mounted device deviceinsideswitchcabinet Mounted on the inside of the arc welding power supply low voltage distribution panel devices.

4 Product Types and basic parameters

4.1 Product Type According to the installation device into a built-in, externally mounted and cabinet-mounted. 4.2 Basic parameters 4.2.1 nominal input conditions Rated input device using the power grid or energy to a secondary loop output arc welding power supply as the input device. 4.2.2 rated current level Rated current level and the arc welding power supply device corresponds to the rated input current, 100A according to R5 recommended the following priority number system tranches; 100A above recommended by R10 priority coefficient bins. Commonly rated current (A) rating. 25,40,63,100,125,160. 4.2.3 Rated duty cycle (%) 20,35,60,80,100. 4.2.4 duty cycle 10min or continuous.

5 conditions of use

5.1 Environmental conditions Shall comply with the relevant provisions of GB 15579.1. 5.2 Special environmental conditions When the environmental conditions of use does not comply with 5.1, the user should be presented when ordering, be resolved through consultation with the manufacturer.

6 Installation conditions

Product demand device shall be specified by the manufacturer for installation.

7 Structure and safety requirements

7.1 motor skills Power supply grid using a device should work correctly in 85% to 110% of rated input voltage; the secondary welding power source Work within the loop output as a means of energy input welding power source should be specified load voltage range. 7.2 start-up time Starting time of the device should not exceed 0.06s. 7.3 Delay time Measuring the delay time of the device under nominal input conditions, measuring 10 times. Delay time in 10 times the maximum and minimum measurement The difference should not exceed the values specified in Table 1, while the maximum delay time should not exceed 1 column in Table 2 of the limits specified. Using the power grid supply apparatus input voltage of 110% and 85% rating, the device respectively 10 trials, seeking The average value of the delay time in each case, the average difference between them and under nominal conditions measured delay time should not exceed 1 List Regulations Value. Table 1 Delay time No-load voltage Delay time Difference between the maximum and minimum Delay time when the average value of power fluctuations The difference between the average value of the rated conditions GB 15579.1 exceed the risk of electric shock Rated load is not an environment for use Voltage 0.3 0.1 0.05 GB 15579.1 in greater danger of electric shock Rated no-load voltage used in the environment Shock and not very dangerous environment to allow When used between rated load voltage 2 0.5 0.3 7.4 Operation Resistance Operation Resistance 7.4.1 device should not exceed 200Ω. 7.4.2 The device corresponding to arc welding power source facilities, safety tests of resistance movements. a) the means and the welding power source are set at nominal input conditions, the welding power secondary circuit series adjustable resistance movement, 10 consecutive tests, each test at the output arc welding power source can produce low no-load voltage; B) When using the power supply for the power grid of the device, the input voltage is adjusted to a value of 110% and 85%, respectively, repeating a), Test the safety of its operation resistance means also should meet the requirements. 7.5 low no-load voltage By means arc welding power source and are rated input conditions, reduced no-load voltage should not exceed the value of nameplate and GB 15579.1 in touch Rated load voltage electrical regulations more dangerous environments values. NOTE. It is recommended to reduce the load voltage as low as possible. 7.6 Terminals Input and output terminals 7.6.1 device should have sufficient mechanical strength, and should have a predetermined fixed table 2 nominal cross-sectional area of the wire ability. Terminals and live parts 7.6.2 devices must be protected. No grid isolated terminals should reach IP2XC requirements. Terminals and welding power source is connected to the secondary circuit should prevent accidental contact with the human body. Table 2 terminals can be connected conductor nominal cross-sectional area Rated maximum (continuous) current Wire cross-sectional area of the range mm2 25 2.5 ~ 6 354 ~ 10 506 ~ 16 6310 ~ 25 8016 - 35 10025 ~ 50 16050 ~ 95 7.7 Structural requirements 7.7.1 The device shall be designed so that only professionals use tools to change the technical parameters of the structure type. 7.7.2 In order to confirm whether the normal operation of the device should be set switches or buttons or use the self-test inspection. 7.7.3 should provide a reliable means (such as lights) indicating electric shock devices work properly. Terminals 7.8 protective conductor Metal enclosure means should be provided with a protective conductor terminals, its ability to hold the wire should be the same as the phase connections. This one Terminals inside can not contact with the electrically neutral terminal, it can not be used for other purposes. And a protective outer-mounted cabinet-mounted device Wire terminals should be marked next to the icon symbol "" or PE words. 7.9 Fault Protection If the device does not work as electric shock 7.3 requires action, the voltage output of the time specified in Table 1 shall be reduced to a low no-load power requirements Pressure value, and it can not be reset automatically. 7.10 normal work location The unit normal installation position in any direction inclined 30 °, it can still work normally. 7.11 fire performance Insulation material used in the device should be able to withstand a fire hazard testing 8.8 requirements. 7.12 clearances and creepage distances According to the provisions of GB 15579.1, the device belongs to overvoltage category Ⅲ, grade 3 or 4 for the pollution of the environment, clearances and creepage distances Shall comply with the provisions of GB 15579.1. 7.13 Insulation resistance And input (output) voltage between live parts connected to each pole, each connected with the housing between the insulation resistance of not less than 2.5MΩ. 7.14 Dielectric strength Between live parts and the input voltage is connected to the poles, the poles are connected together between the shell and should be able to withstand the following test voltage without flash Network or breakdown phenomenon. a) when the device is powered by a power grid, the test voltage AC 1875V; b) When the apparatus by the secondary loop powered welding power source, an AC test voltage 1000V; Grid c) means connected to the welding power source terminal and secondary there is a link between the port test voltage is 3750V. 7.15 Enclosure protection class Shell protection grade outside-mounted device not less than IP21S; for enclosure class externally mounted devices for outdoor use should not be lower In IP23S; enclosure class cabinet-mounted device shall be not less than IP20. 7.16 temperature rise limit Under rated input conditions, means at rated duty cycle run, the temperature rise should not exceed the respective portions of Table 3 The predetermined value. For other devices control device, the temperature rise limits should be consistent with the relevant provisions of the standard control devices. Table 3 temperature rise limit Determination of the position Temperature rise limit Part name materials and insulation levels Thermometer method Resistance method Electromagnetic contactor silver and silver alloy 75 - And electromagnetic contactor Secondary coil of the transformer Power device 60-- 7.17 drop performance Externally mounted and cabinet-mounted device shall be robust mechanical structure. After the drop test according to 8.15, should not have changed causing functional failures Shaped or damaged. 7.18 moist heat resistance The device should be able to wet heat resistance environment. After Damp heat test apparatus to bear 70% of the dielectric strength test voltage assessment, there should be no Breakdown or flashover phenomenon. 7.19 reliability requirements After the device subjected to reliability tests specified in 8.17, its low no-load voltage, start time, delay time and motion resistance should meet this Standards.

8 test methods

8.1 General Type examination when the ambient temperature is 10 ℃ ~ 40 ℃. The device being tested should be completely assembled new, dry. Inspection, measuring instrument accuracy or precision should not be less than. a) electrical measuring instruments. 0.5; b) Thermometer. ± 2K. 8.2 Visual inspection 8.2.1 factory inspection apparatus with technical documentation is complete, complete. 8.2.2 Structure type inspection apparatus of whether the requirements of 7.7. Terminal protective conductor 8.2.3 check whether the device complies with 7.8. 8.3 normal operating position to check The position and orientation of the device by the manufacturer of the product is installed, then any direction inclined 30 °, check whether the device can work properly For which the parameters without changes. 8.4 clearances and creepage distance measurement Clearances and creepage distance detection method in accordance with the provisions of GB 15579.1 performed. 8.5 Housing protection grade test According to GB 4208 requirements for foreign-mounted apparatus and drip-proof test anti-foreign body; for cabinet-mounted device to obstruct the trial. 8.6 Check the insulation resistance measurement DC 500V megger insulation resistance measurement device. After reading the data pointer stable measurement, can not be subjected to the test Electronic components, before measuring the short-circuit or disconnection of these electronic components within the device. Measurement site as follows. Input and output, a) means between the poles; b) inputs and outputs, together with the connection between the device housing. 8.7 Dielectric strength test Dielectric strength test voltage 50Hz AC voltage waveform is approximately sinusoidal, the peak is not more than 1.45 times the RMS. test The duration of the test. type test for the 60s, factory test to 5s. Shall occur during the test flashover or breakdown, leakage current should not exceed their Over 10mA. That can not withstand the test of electronic components, before testing the short circuit or disconnection of these electronic components within the device. Start of the test facilities Plus half of the test voltage does not exceed a predetermined value, and then gradually increased to a predetermined value, duration 60s (or 5s), and then gradually reduced to zero. The dielectric strength test, the same device generally should not be repeated, if necessary, repeated voltage dielectric strength test as prescribed 80% of the value. Dielectric strength test voltage after the damp heat test is 70% of the specified values. The test voltage is applied to the site are as follows. Input and output, a) means between the poles; b) inputs and outputs, together with the means of connection between the housing; Grid c) means of connection between the terminal and the welding power source connected secondary port. 8.8 Fire hazard tests It means to sample parts or insulating material (non-metallic materials) should be GB/T 5169.10 and GB/T 5169.11 regulations Fire hazard testing performed. The glow-wire tip temperature and time applied to the test sample is selected according to Table 4. If several insulating parts made of the same material without the test temperature is the same, only a part of them at a higher temperature into , The experiment results by GB/T 5169.10 and GB/T 5169.11 assessed. Table 4 glow-wire tip temperature and test time Components The glow-wire tip temperature Test time Branch stream carrying member of insulating parts 960 ± 15 30 ± 1 Why he did not carry the stream member of insulating parts 650 ± 15 30 ± 1 8.9 Operation Resistance Measurement Specified by the manufacturer, the device will be mounted on the corresponding arc welding power at rated input conditions, adjust the load in series in the secondary loop Resistance, measuring apparatus ambassador to the maximum resistance value stable operation. The test shall be carried out 10 times, an average value, that is, the resistance movement of the device. The measured resistance action switch connected to the secondary circuit arc welding power source with a voltage measuring device monitors the voltage of the secondary loop. When open After shut off, observe the arc welding power secondary loop is in the no-load voltage state. The test shall be carried out 10 times, the secondary arc welding power back Each road should be in no-load voltage state. When the power supply for the use of the power grid means the input voltage is adjusted to a value of 110% and 85%, respectively, the test is repeated 10 times. 8.10 start time measurement Specified by the manufacturer, the device will be mounted on the corresponding arc welding power at rated input conditions, adjust the load resistance, so as to achieve rated flow. The secondary circuit of welding power source switch is turned on, the measurement is turned on when the transition time to work until the welding power from the secondary circuit. The test shall be repeated five times, the average should not exceed 0.06s. 8.11 delay time measurement 8.11.1 specified by the manufacturer, the device will be mounted on the corresponding arc welding power at rated input conditions, adjust the load resistance, so as to achieve the amount of Constant current. Disconnect the welding power source of the secondary circuit, measuring the welding current from the interrupt load voltage drops to low no-load voltage conversion until the time between. The test was repeated 10 times. The average of 10 measurements, that the delay time of the device. When 8.11.2 for the use of the power grid supply means, the input voltage is adjusted to a value of 110% and 85%, respectively, repeat the......