GB/T 10066.9-2008 English PDFUS$254.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 10066.9-2008: Test methods for electro-heat installations -- Part 9: The determination of power output for High-frequency dielectric heating installation Status: Valid
Basic dataStandard ID: GB/T 10066.9-2008 (GB/T10066.9-2008)Description (Translated English): Test methods for electro-heat installations -- Part 9: The determination of power output for High-frequency dielectric heating installation Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K60 Classification of International Standard: 25.180.10 Word Count Estimation: 13,156 Date of Issue: 2008-09-24 Date of Implementation: 2009-08-01 Older Standard (superseded by this standard): GB/T 14809-2000 Quoted Standard: GB/T 2900.23-2008; GB 5959.9-2008 Adopted Standard: IEC 61308-2005, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the high-frequency dielectric heating device output power measurement method. This section applies to the natural atmosphere and the protection of the atmosphere (for example, an inert gas or vacuum), for such as plastic, wood, rubber, textiles, glass, ceramics, paper, bamboo and food partially conductive or non-conductive material for melting, drying, heat sealing, bonding and other pest control and industrial thermal processing high-frequency dielectric heating device. This section deals with a nominal frequency of 1MHz ~ 300MHz, rated output power greater than 50W useful for high-frequency dielectric heating device. The main purpose of this section is on electric power when tested in GB 5959. 9-2008 promote compliance with the requirements of 6. 4. GB/T 10066.9-2008: Test methods for electro-heat installations -- Part 9: The determination of power output for High-frequency dielectric heating installation---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Test methods for electroheat installtions Part 9. The determination of power output for High-frequency dielectric heating installation ICS 25.180.10 K60 National Standards of People's Republic of China GB/T 10066.9-2008/IEC 61308.2005 Replacing GB/T 14809-2000 Test methods for electric apparatus Part 9. high-frequency dielectric heating apparatus Determination of power output (IEC 61308.2005, High-frequencydielectricheatinginstalations- Testmethodsforthedeterminationofpoweroutput, IDT) Posted 2008-09-24 2009-08-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ 1 Scope and purpose 1 2 Normative references 1 3 Terms and definitions 4 test load 2 4.1 Overview 2 4.2 calorimeter load 2 4.3 Incandescent load 2 4.4 matched resistive load 2 4.5 wet sand load 2 5 Test Method 2 5.1 Overview 2 5.2 calorimeter load method 2 5.3 Incandescent load temperature method 4 5.4 Method 5 matched resistive load 5.5 Method 5 wet sand load Estimated 5.6 high-frequency dielectric plastic heat sealing machine output power of 6 Estimated 5.7 pairs of B-type device output power of 7 Appendix A (informative) recommended test method incandescent lamp load circuit 8 Figure 1 calorimeter meter load Example 3 Figure 2 barrel calorimeter meter load Example 4 Figure 3 incandescent lamp load circuit 4 Incandescent lamp load Figure 4 Example 5 5 5 incandescent load structure 6 plastic heat sealing test electrode 6 Figure A. 1 incandescent lamp load method recommended test circuit 8 GB/T 10066.9-2008/IEC 61308.2005ForewordGB/T 10066 "Standard Test Method for electric apparatus" has 13 sections. --- Part 1. General section (GB/T 10066.1-2004, IEC 60398.1999, MOD); --- Part 2. Induction Channel Furnace (GB/T 10066.2-2004, IEC 60396.1991, MOD); --- Part 3. coreless induction furnace (GB/T 10066.3-2004, IEC 60646.1992, MOD); --- Part 31. high frequency induction heating apparatus of the generator output power measurement (GB/T 10066.31-2007, IEC 61922. 2002, IDT); --- Part 4. Indirect resistance furnaces (GB/T 10066.4-2004, IEC 60397.1994, NEQ); --- Part 5. Test methods ion plasma devices (GB/T 13535-1992 electroheat, neqIEC 60680. 1980); --- Part 6. Determination of industrial microwave heating apparatus of power output (GB/T 10066.6-2008, IEC 61307.2006, IDT); --- Part 7. electric heating apparatus having an electron gun (GB/T 10066.7-2004, IEC 60703. 1981, NEQ); --- Part 8. ESR furnaces (GB/T 10066.8-2006, IEC 60779.2005, IDT); --- Part 9. High-frequency dielectric heating apparatus determination of power output (GB/T 10066.9-2008, IEC 61308.2005, IDT); --- Part 10. Direct electric arc furnace (GB/T 10066.10-2005, IEC 60676.2002, MOD); --- Part 11. submerged arc furnace (GB/T 10066.11-2005, IEC 60683. 1980, MOD); --- Part 12. infrared heating means (GB/T 10066.12-2006). NOTE. Test methods for some of the existing electric device did not use division number (as shown in brackets), in the amendment will change the predetermined number of divisions. This section GB/T Part 910 066 and GB should be safe "electric device 5959.9-2008 Part 9. high frequency Particular requirements for dielectric heating apparatus "used in conjunction. This section identical with IEC 61308.2005 "Determination of high-frequency dielectric heating apparatus of power output," the latter adopted a multi-country Reviews, test circuit wherein Appendix A for our proposed. For ease of use, the IEC 61308.2005, this section made the following editorial changes. --- "This standard" be replaced by "this section"; --- Delete foreword international standards; --- Change "method is a high-frequency dielectric heating device output power" as the test methods "electric devices - Part 9. frequency dielectric Heating output power measuring device ", the English name of the corresponding modification; --- Increase "and the apparatus includes a high frequency generator for heating material in a capacitor, according to the necessary necessary, even a mechanical device." This Part replaces GB/T 14809-2000 "Methods of measurement frequency dielectric heating equipment output power," compared with the latter's main technical Surgery changes are as follows (listed only part of the project name). --- Full text of the "standard" to "this part", according to GB/T 1.1-2000 modify formatting such as Chapter 2, Section 3, etc. headline And the appropriate citation; --- To increase the scope of "bamboo"; Change the original standard "Heat, heat, heat softening and drying process" is "melting, drying, heat sealing, bonding and other thermal processing and pest control Industrial high-frequency dielectric heating apparatus "; --- Equivalent standard adoption, increase the entire contents of "note" of; --- Deleting "output terminals are easy to access"; GB/T 10066.9-2008/IEC 61308.2005 --- Standards adopted by the preparation of terms and their definitions, increase "3.1 A type equipment", "3.2 B type equipment", "3.3 A-type devices Useful output power "," useful output power 3.4 B-type device "and" 3.5 plastic heat sealing test electrode "as used herein and definition; --- Add "4.1 Overview"; --- Mining Standards equivalent number and title, corresponding to modify the original standard of 4.1 to 4.4; --- Increase the "wet sand load 4.5"; --- Add "5.1 Overview"; --- Mining Standards equivalent number and title, corresponding to modify the original standard 5,5.1,5.2 and 5.4; --- Increase the "wet sand load 5.5 Law", 5.6 "high-frequency dielectric plastic heat sealing machine output power estimate," "5.7 pairs of B-type equipment Estimated output power "; --- Mining Standards equivalent figure number and title, corresponding to modify the original standard "Fig. 1a), Fig. 1b), Fig. 2"; --- Increase "incandescent lamp load Figure 4 Example", "5 incandescent load structure", "6 plastic heat sealing test electrode." Appendix A of this section is an informative annex. This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Electric Equipment Industry Standardization Technical Committee (SAC/TC121) centralized. This section is drafted. Xi'an Institute Ltd. furnace. The main drafters of this section. Liu Xiping, Ge Mountain. This part of the standard replaces the previous editions are. --- GB 14809-1993, GB/T 14809-2000. GB/T 10066.9-2008/IEC 61308.2005 Test methods for electric apparatus Part 9. high-frequency dielectric heating apparatus Determination of power output1 Scope and purposeGB/T 10066 provisions of this part of the determination of the high-frequency dielectric heating apparatus of power output. This section applies to the natural ambience and atmosphere (for example, an inert gas or vacuum), for such as plastic, wood, rubber, textiles, glass Glass, ceramics, paper, bamboo and food portion of the conductive or non-conductive material is melted, drying, heat sealing, bonding and other pest control and thermal processing industries High-frequency dielectric heating apparatus. This section refers to the nominal frequency of 1MHz ~ 300MHz, Useful rated output power greater than 50W of high-frequency dielectric heating apparatus. The main purpose of this section at the time of the electric power supply test, facilitate their compliance with the provisions of 6.4 GB 5959.9-2008 to begging. It basically does not make some kind of high-frequency heating may be applied to meet the user's requirements. Dielectric heating applications is very wide, so these tests Any output power is always obtained value should not be used to represent a specific dielectric heating apparatus capable of power consumed, but in some cases, The output value will be used to represent the performance of the device. For example, the structure of the power required for the furnace and its feed material, the heating temperature, humidity and the relevant electrode systems. Note. When heating the dielectric parameters over time and/or temperature changes significantly charge, charge the actual output power values \u200b\u200bobtained with the standard test strip Different values \u200b\u200bobtained pieces. Means the specified band for working in the International Telecommunication Union (ITU), the frequency of the generator is to follow the output circuit of the resonant frequency, which Thus, the output power even in the case of manual tuning of the output circuit, to remain fairly stable in the working cycle. Therefore, in accordance with this section, Test well shows under actual operating conditions of real output power. Within a specified frequency band of the device working in the International Telecommunication Union (ITU), the frequency generator remained stable, but the resonant frequency of the output circuit It varies with the load change media parameters. Therefore, the value of the average output power than in the work cycle under the test conditions of low to obtain many. The value depends on the time automatic tuning system response. This section applies to equipment under normal rated conditions of continuous operation.2 Normative referencesThe following documents contain provisions which, through reference GB/T 10066 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 2900.23-2008 Electrotechnical terminology industrial electric equipment (IEC 60050-841.2004, IDT) GB 5959.9-2008 Safety of electric devices - Part 9. Particular requirements (IEC 60519-9 high-frequency dielectric heating apparatus. 2005, IDT)3 Terms and DefinitionsGB/T 2900.23-2008 and GB 5959.9-2008 to establish the following terms and definitions apply to this section. 3.1 Generator having a dielectric heating device separate from the applicator, for example, high-frequency power can be applied to the device through the coaxial cable. GB/T 10066.9-2008/IEC 61308.2005 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 10066.9-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 10066.9-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 10066.9-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 10066.9-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |