GB/T 5013.7-2008: Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 7: Heat resistant ethylene-vinyl acetate rubber insulated cables
Status: Valid

GB/T 5013.7: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 5013.7-2008154 Add to Cart 3 days Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 7: Heat resistant ethylene-vinyl acetate rubber insulated cables Valid
GB 5013.7-1997239 Add to Cart 3 days Rubber insulated cables of rated voltages up to and including 450/750V. Part 7: Heat resistant ethylene-vinyl acetate rubber insulated cables Obsolete

Similar standards

GB/T 5023.3   GB/T 3956   GB/T 5013.1   GB/T 5013.8   GB/T 5013.3   GB/T 5013.4   

Basic data

Standard ID: GB/T 5013.7-2008 (GB/T5013.7-2008)
Description (Translated English): Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 7: Heat resistant ethylene-vinyl acetate rubber insulated cables
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K13
Classification of International Standard: 29.060.20
Word Count Estimation: 8,810
Date of Issue: 2008-01-22
Date of Implementation: 2008-09-01
Older Standard (superseded by this standard): GB 5013.7-1997
Quoted Standard: GB/T 2951.1-1997; GB/T 2951.2-1997; GB/T 2951.5-1997; GB/T 2951.6-1997; GB/T 3956; GB/T 5013.1-2008; GB/T 5013.2-2008
Adopted Standard: IEC 60245-7-1994, IDT
Regulation (derived from): Announcement of Newly Approved National Standards No. 2, 2008 (No. 115 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the rated voltage 450/750V ethylene vinyl acetate rubber insulated cables technical requirements. Each cable shall comply with GB/T 5013. 1 requirements and the special requirements of this section.

GB/T 5013.7-2008: Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 7: Heat resistant ethylene-vinyl acetate rubber insulated cables


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rubber insulated cables of rated voltages up to and including 450/750 V. Part 7. Heat resistant ethylene-vinyl acetate rubber insulated cables ICS 29.060.20 K13 National Standards of People's Republic of China GB/T 5013.7-2008/IEC 60245-7.1994 Replacing GB 5013.7-1997 Rated voltage 450/750 and below Vp Rubber insulated cables Part 7. Heat resistant ethylene - vinyl acetate Rubber insulated cables (IEC 60245-7.1994, IDT) Posted 2008-09-01 2008-01-22 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

GB/T 5013 "rated voltage 450/750V and below rubber insulated cable" is divided into eight sections. --- Part 1. General requirements; --- Part 2. Test methods; --- Part 3. Heat resistant silicone rubber insulated cables; --- Part 4. Cords and flexible cables; --- Part 5. Lift cables; --- Part 6. Arc welding cables; --- Part 7. Heat resistant ethylene - vinyl acetate rubber insulated cables; --- Part 8. Cords. This section GB/T 5013 Part 7. This section identical with IEC 60245-7.1994 "rated voltage 450/750V and with Under rubber insulated cables Part 7. Heat resistant ethylene - vinyl acetate rubber insulated cables "(in English) and its amendments Amendment1. 1997 (in English). For ease of use, GB/T 5013 made this part of the following editorial changes. "." --- With a decimal point instead of a comma as the decimal point, ""; --- Delete international standards foreword. This part of IEC original 2.3.4 and 3.3.4 corresponding editorial errors were corrected. This section from the implementation date instead of GB 5013.7-1997. This section of the main changes compared to GB 5013.7-1997 are as follows. --- Table 1 and Table 3, increased the average outer diameter of the lower limit, the average outer diameter of the cap and modify the value. This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee of wire and cable. This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute. Participated in the drafting of this section. Jiangsu Shangshang Cable Group, Kunming Cable Co., Ltd., Qingdao Hanlan Group Co., Ltd., Hainan Yang Cable Co., Ltd., Tianjin Jinshan Electric Wire & Cable Co., Ltd., Wuxi Jiangnan Cable Co., Ltd. The main drafters of this section. gold righteousness, talk Jianwei, He Wenjun, Zhang Liming, Tan Jinfeng, Zheng Guojun, Xia Yafang. This part of the standard replaces the previous editions as. GB 5013.7-1997. GB/T 5013.7-2008/IEC 60245-7.1994 Rated voltage 450/750 and below Vp Rubber insulated cables Part 7. Heat resistant ethylene - vinyl acetate Rubber insulated cables

1 Overview

1.1 Scope This section GB/T 5013 gives a rated voltage of 450/750V and below, ethylene - vinyl acetate rubber insulated cable technology Claim. Each cable shall comply with the requirements and the specific requirements of this part of GB/T 5013.1 regulations. 1.2 Normative references The following documents contain provisions which, through GB/T reference in this 5013 constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 2951.1-1997 cable insulation and sheathing materials test methods - Part 1. General Test Methods 1. Thick Degree and dimensions measuring --- mechanical tests (idt IEC 60811-1-1.1993) GB/T 2951.2-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 2. Hot Aging methods (idt IEC 60811-1-2. 1985) GB/T 2951.5-1997 cable insulation and sheathing materials test methods - Part 2. elastomeric compounds specific test side Act 1. Ozone resistance test --- --- Hot set test - Mineral oil immersion test (idt IEC 60811-2-1. 1986) GB/T 2951.6-1997 cable insulation and sheathing materials test methods - Part 3. Test method specific to PVC compounds Act 1. temperature pressure test - resistance to cracking (idt IEC 60811-3-1. 1985) GB/T 3956 cable conductor (GB/T 3956-1997, idt IEC 60228. 1978) GB/T 5013.1-2008 rated voltage of 450/750V and below rubber insulated cables - Part 1. General requirements (IEC 60245-1.2003, IDT) GB/T 5013.2-2008 rated voltage of 450/750V and below rubber insulated cables - Part 2. Test methods (IEC 60245-2.1998, IDT) 2 maximum conductor temperature of 110 ℃ heat-resistant ethylene - vinyl acetate rubber or other equivalent synthetic elastomer insulated, single-core, non-sheathed 750 Vp cable 2.1 Model Solid or stranded conductors. 60245IEC 04 (YYY); Flexible conductor. 60245IEC 05 (YRYY). 2.2 Rated voltage 450/750V. 2.3 Structure 2.3.1 Conductor Number of cores. a core. Conductor shall comply with GB/T 3956 requirements. GB/T 5013.7-2008/IEC 60245-7.1994
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 5013.7-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 5013.7-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 5013.7-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 5013.7-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 5013.7-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5013.7-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.