GB/T 5013.8-2013 English PDF

US$274.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 5013.8-2013: Rubber insulated cables -- Rated voltages up to and including 450/750 V -- Part 8: Cords for applications requiring high flexibility
Status: Valid

GB/T 5013.8: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 5013.8-2013274 Add to Cart 3 days Rubber insulated cables -- Rated voltages up to and including 450/750 V -- Part 8: Cords for applications requiring high flexibility Valid
GB/T 5013.8-2006599 Add to Cart 3 days Section 8 of the rated voltage 450/750V rubber insulated cables.: Cords Obsolete

GB/T 5013.8-2013: Rubber insulated cables -- Rated voltages up to and including 450/750 V -- Part 8: Cords for applications requiring high flexibility


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
. Rubber insulated cables Rated voltages up to and including 450/750 V. Part 8. Cords for applications requiring high flexibility ICS 29.060.20 K13 National Standards of People's Republic of China Replacing GB/T 5013.8-2006 Rated voltage of 450/750V and below rubber insulated cables Part 8. Cords Part 8. Cordsforapplicationsrequiringhighflexibility (IEC 60245-8.2004, IDT) Issued on. 2013-07-19 2013-12-02 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Overview 1 2 Standby 1 3 Alternate 1 4 Reserved 1 5 ethylene-propylene rubber (EPR) insulated braided sheath Cords 1 Appendix A spare 5 Appendix B (normative) Test Method 6 braid coverage Appendix NA (informative) Model representation 8 Appendix NB (informative) Model control 9

Foreword

GB/T 5013 "rated voltage 450/750V and below rubber insulated cable" is divided into eight sections. --- Part 1. General requirements; --- Part 2. Test methods; --- Part 3. Heat resistant silicone rubber insulated cables; --- Part 4. Cords and flexible cables; --- Part 5. Lift cables; --- Part 6. Arc welding cables; --- Part 7. Heat resistant ethylene - vinyl acetate rubber insulated cables; --- Part 8. Cords. This section GB/T 5013 Part 8. This section drafted in accordance with GB/T 1.1-2009 given rules. This Part replaces GB/T 5013.8-2006 "rated voltage 450/750V Rubber insulated cables and Part 8. Special soft power line". Compared with GB/T 5013.8-2006, the main changes are as follows. --- Delete the contents of rubber insulation and sheathing Cords (see the 2006 edition of Chapter 2); --- Delete the contents of rubber insulated XLPE (XLPVC) jacket Cords (see Chapter 3 edition 2006); --- Delete the contents of XLPE (XLPVC) insulation and sheathing Cords (see Appendix A 2006 version of Chapter 4); --- Increasing the EPR (EPR) insulation and braided sheath Cords technical specifications and requirements (see Chapter 5); --- Increased braid coverage test methods (see Appendix B); --- Modify the Model table (see Appendix NB, 2006 Edition Appendix C). This section uses the translation method is equivalent to using the International Electrotechnical Commission standard IEC 60245-8.2004 "rated voltage 450/750V and below Rubber insulated cables - Part 8. Cords "Version No. 1.1 second amendments (2011). This part identical with IEC 60245-8.2004 Fixed the description of several editorial errors. These amendments are as follows. --- IEC 60245-8.2004 5.4.2 in the original error, Table 2 should be changed to Table 9, this section has been amended accordingly. 60245IEC 89 (RQB).
......

Basic data

Standard ID: GB/T 5013.8-2013 (GB/T5013.8-2013)
Description (Translated English): Rubber insulated cables -- Rated voltages up to and including 450/750 V -- Part 8: Cords for applications requiring high flexibility
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K13
Classification of International Standard: 29.060.20
Word Count Estimation: 14,129
Older Standard (superseded by this standard): GB/T 5013.8-2006
Quoted Standard: GB/T 2951.11-2008; GB/T 2951.12-2008; GB/T 2951.21-2008; GB/T 3956-2008; GB/T 5013.1-2008; GB/T 5013.2-2008; IEC 60719
Adopted Standard: IEC 60245-8-2004, IDT
Regulation (derived from): National Standards Bulletin 2013 No. 10
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the rated voltage of 300/300V, requires special soft occasions (such as iron) used rubber insulation and textile braid Cords technical requirements. Each wire shall comply with GB/T 5013. 1-2008 requirements and the special require

Similar standards

GB/T 5023.3   GB/T 3956   GB/T 5013.1   GB/T 5013.4   GB/T 5013.5   GB/T 5013.3   


Image
Click 2 Tabs (IMAGE/PDF) above for more information.