GB/T 5013.6-2008 English PDFUS$114.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 5013.6-2008: Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 6: Arc welding electrode cables Status: Valid GB/T 5013.6: Historical versions
Basic dataStandard ID: GB/T 5013.6-2008 (GB/T5013.6-2008)Description (Translated English): Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 6: Arc welding electrode cables Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K13 Classification of International Standard: 29.060.20 Word Count Estimation: 6,652 Date of Issue: 2008-01-22 Date of Implementation: 2008-09-01 Older Standard (superseded by this standard): GB 5013.6-1997 Quoted Standard: GB/T 2951.1-1997; GB/T 2951.2-1997; GB/T 2951.5-1997; GB/T 5013.1-2008; GB/T 5013.2-2008 Adopted Standard: IEC 60245-6-1994, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 2, 2008 (No. 115 overall) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the technical rubber insulated welding cable requirements. Each cable shall comply with GB/T 5013. 1 requirements and the special requirements of this section. GB/T 5013.6-2008: Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 6: Arc welding electrode cables---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Rubber insulated cables of rated voltages up to and including 450/750 V. Part 6. Arc welding electrode cables ICS 29.060.20 K13 National Standards of People's Republic of China GB/T 5013.6-2008/IEC 60245-6.1994 Replacing GB 5013.6-1997 Rated voltage 450/750 Vp and rubber insulated Cables - Part 6. Arc welding cables (IEC 60245-6.1994, IDT) Posted 2008-01-22 2008-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordGB/T 5013 "rated voltage 450/750V and below rubber insulated cable" is divided into eight sections. --- Part 1. General requirements; --- Part 2. Test methods; --- Part 3. Heat resistant silicone rubber insulated cables; --- Part 4. Cords and flexible cables; --- Part 5. Lift cables; --- Part 6. Arc welding cables; --- Part 7. Heat resistant ethylene - vinyl acetate rubber insulated cables; --- Part 8. Cords. This section GB/T 5013 Part 6. This section identical with IEC 60245-6.1994 "rated voltage 450/750V and with Rubber insulated cables under Part 6. Welding cable "(in English) and its amendments Amendment1.1997, Amendment2. 2003 (in English). For ease of use, GB/T 5013 made this part of the following Edit Review. "." --- With a decimal point instead of a comma as the decimal point, ""; --- Delete international standards foreword. This section instead of from the date of implementation of the GB/T 5013.6-1997. This section of the main changes compared to GB 5013.6-1997 are as follows. --- Insulating material "IE4" instead of "IE1"; --- Table 1 reduces the average outer diameter of the lower and upper values \u200b\u200band footnotes 2 "Measurement of coating thickness shall GB/T 5013.1- 5.5.3 The provisions in 2008 "; --- Table 2 3.3 "after oxygen bomb aging tensile testing" replaced by "air missile after aging tensile testing" and add 3.5 "Ozone test". This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee of wire and cable. This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute. Participated in the drafting of this section. Guangdong Huasheng Electric Industrial Co., Ltd., Jiangsu on the cable group, Kunming Cable Co., Ltd., Qingdao Hanlan Group Co., Ltd., Shanghai Nanyang Cable Co., Ltd., Wuxi Jiangnan Cable Co., Ltd. The main drafters of this section. gold justice, Zhuju Tao, Tan Jianwei, He Wenjun, Zhang Liming, Tan Jinfeng, Xia Yafang. This part of the standard replaces the previous editions as. GB 5013.3-1985, GB 5013.6-1997. GB/T 5013.6-2008/IEC 60245-6.1994 Rated voltage 450/750 Vp and rubber insulated Cables - Part 6. Arc welding cables1 Overview1.1 Scope GB/T 5013 This section gives the technical requirements of rubber insulated welding cable. Each cable shall comply with the requirements and the specific requirements of this part of GB/T 5013.1 regulations. 1.2 Normative references The following documents contain provisions which, through GB/T reference in this 5013 constitute provisions of this section. For dated references, All subsequent amendments (excluding corrections) or revisions do not apply to this section, however, encourage an agreement under this section Parties to study the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 2951.1-1997 cable insulation and sheathing materials test methods - Part 1. General Test Methods 1. Thick Degree and dimensions measuring --- mechanical tests (idt IEC 60811-1-1.1993) GB/T 2951.2-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 2. Hot Aging methods (idt IEC 60811-1-2. 1985) GB/T 2951.5-1997 cable insulation and sheathing materials test methods - Part 2. elastomeric compounds specific test side Act 1. Ozone resistance test --- --- Hot set test - Mineral oil immersion test (idt IEC 60811-2-1. 1986) GB/T 5013.1-2008 rated voltage of 450/750V and below rubber insulated cables - Part 1. General requirements (IEC 60245-1.2003, IDT) GB/T 5013.2-2008 rated voltage of 450/750V and below rubber insulated cables - Part 2. Test methods (IEC 60245-2.1998, IDT)2 Welding cable2.1 Model Rubber Welding cable. 60245IEC 81 (YH); Neoprene or other equivalent synthetic elastomer insulated welding cables. 60245IEC 82 (YHF). 2.2 Rated voltage Since this type of cable is dedicated to welding, so the rated voltage is not specified. 2.3 Structure 2.3.1 Conductor Number of cores. a core. Conductor shall comply with the requirements specified in Table 1 column 2. Single line can not tin or tin. 2.3.2 spacer layer It should be applied around a conductor layer made of a suitable material for the isolation layer. 2.3.3 overlay Conductor and the isolation layer by following one covering layer protection. 2.3.3.1 The minimum tensile strength of 12MPa SE3 rubber mixture is extruded covering layer constituting the insulation and jacket, and its thickness should be consistent Value specified in Table 1, column 3. GB/T 5013.6-2008/IEC 60245-6.1994 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5013.6-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 5013.6-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 5013.6-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5013.6-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 5013.6-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5013.6-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |