GB/T 5013.5-2008: Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 5: Lift cables
Status: Valid

GB/T 5013.5: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 5013.5-2008134 Add to Cart 3 days Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 5: Lift cables Valid
GB 5013.5-1997199 Add to Cart 3 days Rubber insulated cables of rated voltages up to and including 450/750V. Part 5: Lift cables Obsolete

Similar standards

GB/T 5023.3   GB/T 3956   GB/T 5013.1   GB/T 5013.8   GB/T 5013.3   GB/T 5013.4   

Basic data

Standard ID: GB/T 5013.5-2008 (GB/T5013.5-2008)
Description (Translated English): Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 5: Lift cables
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K13
Classification of International Standard: 29.060.20
Word Count Estimation: 7,746
Date of Issue: 2008-01-22
Date of Implementation: 2008-09-01
Older Standard (superseded by this standard): GB 5013.5-1997
Quoted Standard: GB/T 2951.1-1997; GB/T 2951.2-1997; GB/T 2951.5-1997; GB/T 3956; GB/T 5013.1-2008; GB/T 5013.2-2008
Adopted Standard: IEC 60245-5-1994, IDT
Regulation (derived from): Announcement of Newly Approved National Standards No. 2, 2008 (No. 115 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the rated voltage 300/500V rubber insulated lift cables technical requirements. Each cable shall meet the requirements specified in GB 5013. 1 and the special requirements of this section.

GB/T 5013.5-2008: Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 5: Lift cables


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rubber insulated cables of rated voltages up to and including 450/750 V. Part 5. Lift cables ICS 29.060.20 K13 National Standards of People's Republic of China GB/T 5013.5-2008/IEC 60245-5.1994 Replacing GB 5013.5-1997 Rated voltage 450/750 Vp and rubber insulated cables Part 5. Lift cables (IEC 60245-5.1994, IDT) Posted 2008-01-22 2008-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

GB/T 5013 "rated voltage 450/750V and below rubber insulated cable" is divided into eight sections. --- Part 1. General requirements; --- Part 2. Test methods; --- Part 3. Heat resistant silicone rubber insulated cables; --- Part 4. Cords and flexible cables; --- Part 5. Lift cables; --- Part 6. Arc welding cables; --- Part 7. Heat resistant ethylene - vinyl acetate rubber insulated cables; --- Part 8. Cords. This section GB/T 5013 Part 5. This section identical with IEC 60245-5.1994 "rated voltage 450/750V and with Under rubber insulated cables - Part 5. Lift cables "(in English) and its amendments Amendment1.2003 (English version). For ease of use, GB/T 5013 made this part of the following editorial changes. --- As an alternative to the decimal by decimal comma ",". ","; --- Delete international standards foreword. This section from the date of implementation of alternative GB/T 5013.5-1997. This section of the main changes compared to GB 5013.5-1997 are as follows. --- 2.3.2 "isolation layer" removed "the relevant requirements see GB 5013.1-1997 5.1.3"; --- Insulating material "IE4" replacement "IE1"; --- Table 2 3.3 pilot project to "air missile after aging tensile test"; --- Table 2 increased 3.5 Test Project "Ozone Test." This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee of wire and cable. This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute. Participated in the drafting of this section. Hualing Cable Group Co., Ltd., Fujian Nanping Sun Cable Co., Ltd., Guangdong Huasheng Electric Is Industrial Co., Ltd., Jiangsu Cable Group, Shanghai Nanyang Electric Wire Co., Ltd., Wuxi Jiangnan Cable Co., Ltd. The main drafters of this section. gold justice, Huguang Zheng, Ke Zonghai, Zhuju Tao, Tan Jianwei, Huang Deyi, Xia Yafang. This part of the standard replaces the previous editions as. GB 5013.4-1987, GB 5013.5-1997. GB/T 5013.5-2008/IEC 60245-5.1994 Rated voltage 450/750 Vp and rubber insulated cables Part 5. Lift cables

1 Overview

1.1 Scope GB/T 5013 This section gives the rated voltage of 300/500V rubber insulated technical requirements for elevator cables. Each cable shall comply with the requirements and the specific requirements of this part of GB/T 5013.1 regulations. 1.2 Normative references The following documents contain provisions which, through GB/T reference in this 5013 constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 2951.1-1997 cable insulation and sheathing materials test methods - Part 1. General Test Methods 1. Thick Degree and dimensions measuring --- mechanical tests (idt IEC 60811-1-1.1993) GB/T 2951.2-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 2. Hot Aging methods (idt IEC 60811-1-2. 1985) GB/T 2951.5-1997 cable insulation and sheathing materials test methods - Part 2. elastomeric compounds specific test side Act 1. Ozone resistance test --- --- Hot set test - Mineral oil immersion test (idt IEC 60811-2-1. 1986) GB/T 3956 cable conductor (GB/T 3956-1997, idt IEC 60228. 1978) GB/T 5013.1-2008 rated voltage of 450/750V and below rubber insulated cables - Part 1. General requirements (IEC 60245-1.2003, IDT) GB/T 5013.2-2008 rated voltage of 450/750V and below rubber insulated cables - Part 2. Test methods (IEC 60245-2.1998, IDT) Woven, high-strength rubber, neoprene or other equivalent synthetic elastomer 2 general-purpose rubber elevator cable 1) 1) high-speed or high-rise building with an elevator cable elevator cable standards are under consideration. 2) does not exclude other structure containing a cable core number or more number of cores. 2.1 Model Braided elevator cable. 60245IEC 70 (YTB); High strength rubber elevator cable. 60245IEC 74 (YT); Neoprene or other equivalent synthetic elastomer insulated lift cables. 60245IEC 75 (YTF). 2.2 Rated voltage 300/500V. 2.3 Structure 2.3.1 Conductor Contacts. 6,9,12,18,24 or 30 core 2). Conductor shall meet the requirements of GB/T 3956 in the fifth conductor specified, but the maximum resistance value of the conductor at 20 ℃ shall be increased by 5%. single Line may not be tinned or tin. 2.3.2 spacer layer It may be coated with a layer of suitable material of the spacer layer outside of each conductor. GB/T 5013.5-2008/IEC 60245-5.1994
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 5013.5-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 5013.5-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 5013.5-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 5013.5-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 5013.5-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5013.5-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.