GB 19577-2024 PDF EnglishUS$335.00 · In stock · Download in 9 seconds
GB 19577-2024: Minimum allowable values of the energy efficiency and energy efficiency grades for heat pumps and water chillers Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB 19577: Historical versions
GB 19577-2024: Minimum allowable values of the energy efficiency and energy efficiency grades for heat pumps and water chillers---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB19577-2024 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 27.010 CCS F 01 Replacing GB 19577-2015, GB 29540-2013, GB 30721-2014, GB 37480-2019 Minimum allowable values of the energy efficiency and energy efficiency grades for heat pumps and water chillers Issued on. APRIL 29, 2024 Implemented on. FEBRUARY 01, 2025 Issued by. State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of ContentsForeword... 3 1 Scope... 5 2 Normative references... 5 3 Terms and definitions... 6 4 Energy efficiency grades... 8 5 Technical requirements... 12 6 Tests and calculation methods... 13 7 Implementation of the document... 14 Annex A (normative) Tests and calculation methods for the cooling seasonal performance factor of air-cooled comfort chillers (CC ≤ 50 kW)... 15 Minimum allowable values of the energy efficiency and energy efficiency grades for heat pumps and water chillers1 ScopeThis document specifies the technical requirements for the minimum allowable values of the energy efficiency and energy efficiency grades for heat pumps and water chillers, describes the corresponding test methods, and clarifies the implementation of this document. The types of heat pumps and chillers to which this document applies include water chilling (heat pump) packages using the vapor compression, low ambient temperature air source heat pump (water chilling) packages, water-source (ground-source) heat pumps, lithium bromide absorption water chillers (heaters), water-source high temperature heat pumps using the vapor compression cycle, indirect evaporative cooling water chillers, and integrated water chilling (heat pump) packages.2 Normative referencesThe following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 10870 The methods of performance test for water chilling (heat pump) packages using the vaper compression cycle GB/T 18362 Direct-fired lithium bromide absorption water chiller (heater) GB/T 18430.1 Water chilling (heat pump) packages using the vapor compression cycle - Part 1.Water chilling (heat pump) packages for industrial & commercial and similar application GB/T 18430.2 Water chilling (heat pump) packages using the vapor compression cycle - Part 2.Water chilling (heat pump) packages for household and similar application GB/T 18431 Steam and hot water type lithium bromide absorption water chiller GB/T 19409 Water-source (ground-source) heat pumps Under the specified standard operating conditions, the minimum allowable values of the nominal heating coefficient of performance (COPh), low temperature heating coefficient of performance (COPdh), heating seasonal performance factor (HSPF) and (or) annual performance factor (APF) of low ambient temperature air source heat pump (water chilling) packages. GB/T 25127.1 Low ambient temperature air source heat pump (water chilling) packages - Part 1.Heat pump (water chilling) packages for industrial & commercial and similar application GB/T 25127.2 Low ambient temperature air source heat pump (water chilling) packages - Part 2.Heat pump (water chilling) packages for household and similar application GB/T 25861 Water-source high temperature heat pumps using the vapor compression cycle JB/T 12839 Integrated water chilling (heat pump) package JB/T 12840 Air source heat pump high temperature hot air & hot water unit JB/T 14640 Composite indirect evaporative cooling water chiller for computer and data processing room JB/T 14642 High-leaving water temperature chiller base on dew point indirect evaporative cooling3 Terms and definitionsFor the purpose of this document, the terms and definitions defined in GB/T 18430.1, GB/T 18430.2, GB/T 18362, GB/T 18431, GB/T 10870, GB/T 19409, GB/T 25127.1, GB/T 25127.2, GB/T 25861, JB/T 14640, JB/T 14642 and JB/T 12839 and the following apply. 3.1 minimum allowable values of energy efficiency for water chilling (heat pump) packages using the vapor compression Under the specified standard operating conditions, the minimum allowable values of the coefficient of performance (COPc), integrated part load value (IPLV), annual comprehensive cooling coefficient of performance (ACCOP) and (or) cooling seasonal performance factor (CSPF) of water chilling (heat pump) packages using the vapor compression. 3.2 minimum allowable values of energy efficiency for low ambient temperature air source heat pump (water chilling) packages Buy True-PDF Auto-delivery. Page 7 of 20 Under the specified standard operating conditions, the minimum allowable values of the nominal heating coefficient of performance (COPh), low temperature heating coefficient of performance (COPdh), heating seasonal performance factor (HSPF) and (or) annual performance factor (APF) of low ambient temperature air source heat pump (water chilling) packages. 3.3 minimum allowable values of energy efficiency for water-source (ground-source) heat pumps Under the specified standard operating conditions, the minimum allowable values of the annual comprehensive coefficient of performance (ACOP) or heating coefficient of performance (COP) of water-source (ground-source) heat pumps. NOTE. For heat-pump units, the annual comprehensive coefficient of performance (ACOP) is assessed; for single-heat units, the heating coefficient of performance (COP) is assessed. 3.4 minimum allowable values of energy efficiency for lithium bromide absorption water chillers (heaters) Under the specified standard operating conditions, the minimum allowable values of the coefficient of performance (COP) or the maximum values of the heating source consumption per unit cooling capacity of lithium bromide absorption water chillers (heaters). NOTE. For vapor units, the heating source consumption per unit cooling capacity is assessed; for direct-fired units, the coefficient of performance (COP) is assessed. 3.5 minimum allowable values of energy efficiency for water-source high temperature heat pumps using the vapor compression cycle Under the specified standard operating conditions, the minimum allowable values of the heating coefficient of performance of water-source high temperature heat pumps using the vapor compression cycle. NOTE. For water-source high temperature heat pumps, the heating coefficient of performance (COPH) is assessed; for periodical feeding heat pump high temperature hot water units, the heating coefficient of performance (COP) is assessed. 3.6 minimum allowable values of energy efficiency for indirect evaporative cooling water chillers Under specified standard operating conditions, the minimum allowable values of the annual energy efficiency ratio (AEER) or energy efficiency ratio (EER) of indirect evaporative cooling water chillers. NOTE. For high-leaving water temperature chillers base on dew point indirect evaporative cooling used in data centers and similar places, the annual energy efficiency ratio (AEER) is assessed; for composite indirect evaporative cooling water chillers used in computer and data processing rooms, the energy efficiency ratio (EER) is assessed. 3.7 minimum allowable values of energy efficiency for integrated water chilling (heat pump) package Under specified standard operating conditions, the minimum allowable values of the integrated part load value (IPLVI) and nominal operating coefficient of performance (COPI) of integrated water chilling (heat pump) packages. NOTE. For vapor-cooled, cooling-tower and air-cooled units, the integrated part load value (IPLVI) and nominal operating coefficient of performance (COPI) are assessed.4 Energy efficiency grades4.1 The energy efficiency grades for heat pumps and water chillers are divided into 3 grades, among which grade 1 has the highest energy efficiency. 4.2 The measured values and nominal values of the energy efficiency indicators of various types of heat pumps and water chillers shall not be less than the specified values corresponding to the energy efficiency grades in Tables 1 to 8.Among them, the indicators of energy efficiency grades for water chilling (heat pump) packages using the vapor compression adopt dual-channel evaluation indicators, i.e., select the energy efficiency value of one of the indicator systems in the comprehensive part load value (IPLV) (see Table 1) or the coefficient of performance (COPc) (see Table 2) to determine the energy efficiency grade.5 Technical requirements5.1 The minimum allowable values of energy efficiency for water chilling (heat pump) packages using the vapor compression, the minimum allowable values of energy efficiency for low ambient temperature air source heat pump (water chilling) packages, the minimum allowable values of energy efficiency for water-source (ground-source) heat pumps, the minimum allowable values of energy efficiency for lithium bromide absorption water chillers (heaters), the minimum allowable values of energy efficiency for water-source high temperature heat pumps using the vapor compression cycle, the minimum allowable values of energy efficiency for indirect evaporative cooling water chillers, and the minimum allowable values of energy efficiency for integrated water chilling (heat pump) packages are the indicator values corresponding to energy efficiency grade 3 in Tables 1 to 8. 5.2 For low ambient temperature air source heat pump (water chilling) packages with electric auxiliary heating, the electric auxiliary heating system shall be manually turned on and off, and its working status shall be expressed in an obvious position. 5.3 The marked values of energy efficiency for heat pumps and water chillers shall be within the range of values corresponding to their rated energy efficiency grades, and the measured values of energy efficiency shall not be less than the provisions in the corresponding product standards in Tables 1 to 8.6 Tests and calculation methods6.1 The energy efficiency test method for water chilling (heat pump) packages using the vapor compression shall be carried out in accordance with the relevant provisions of GB/T 18430.1 and GB/T 18430.2.The test and calculation of air-cooled comfort chillers with a nominal cooling capacity not exceeding 50 kW shall be carried out in accordance with the provisions of Annex A. 6.2 The energy efficiency test method for low ambient temperature air source heat pump (water chilling) packages shall be carried out in accordance with the relevant provisions of GB/T 25127.1 and GB/T 25127.2. 6.3 The energy efficiency test method for water-source (ground-source) heat pumps shall be carried out in accordance with the relevant provisions of GB/T 19409. 6.4 The energy efficiency test method of lithium bromide absorption water chillers (heaters) shall be carried out in accordance with the relevant provisions of GB/T 18431 and GB/T 18362. 6.5 The energy efficiency test method for water-source high temperature heat pumps using the vapor compression cycle shall be carried out in accordance with the relevant provisions of GB/T 25861 and JB/T 12840. 6.6 The energy efficiency test method for indirect evaporative cooling water chillers shall be carried out in accordance with the relevant provisions of JB/T 14642 and JB/T 14640.The dry-bulb and wet-bulb temperature distribution coefficients, used for the test conditions and calculation of the annual energy efficiency ratio (AEER) of high- leaving water temperature chillers base on dew point indirect evaporative cooling used in data centers and similar places, are tested and calculated according to the provisions for cold regions (refer to Beijing) in JB/T 14642 (referenced to Beijing).7 Implementation of the documentProducts produced or imported on the date of implementation of this document shall comply with the requirements of this document. The sales of products produced or imported before the implementation of this document shall only be delayed until the 24th month after the implementation of this document. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB 19577-2024 be delivered?Answer: The full copy PDF of English version of GB 19577-2024 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB 19577-2024_English with my colleagues?Answer: Yes. The purchased PDF of GB 19577-2024_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB 19577-2024 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version GB 19577-2024?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 19577-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of GB 19577-2024?A step-by-step guide to download PDF of GB 19577-2024_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB 19577-2024". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |