GB 1886.222-2016 English PDFUS$399.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 1886.222-2016: Food additive -- Allura red Status: Valid
Basic dataStandard ID: GB 1886.222-2016 (GB1886.222-2016)Description (Translated English): Food additive -- Allura red Sector / Industry: National Standard Classification of Chinese Standard: X42 Word Count Estimation: 20,284 Date of Issue: 2016-08-31 Date of Implementation: 2017-01-01 Older Standard (superseded by this standard): GB 17511.1-2008 Regulation (derived from): Announcement of the State Administration of Public Health and Family Planning 2016 No.11 Issuing agency(ies): National Health and Family Planning Commission of the People's Republic of China, State Food and Drug Administration GB 1886.222-2016: Food additive -- Allura red---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.(Food safety national standard - Food additive - Red temptation) National Standards of People's Republic of China GB 1886.225-2016 National Food Safety Standard Food additive Ethoxyquin Issued on. 2016-08-31 2017-01-01 implementation People's Republic of China National Health and Family Planning Commission released GB 1886.225-2016 National Food Safety Standard Food additive Ethoxyquin 1 ScopeThis standard applies to p-aminophenyl ether and acetone as raw materials in the catalyst and heating the reaction conditions to prepare food additive ethoxy Quinoline group. 2 chemical name, structural formula, molecular formula and relative molecular mass 2.1 Chemical Name 6-ethoxy-1,2-dihydro-2,2,4-trimethyl quinoline 2.2 formula Formula 2.3 C14H19NO 2.4 relative molecular mass 217.31 (according to 2011 international relative atomic mass)3 Technical requirements3.1 Sensory requirements Sensory requirements shall comply with the requirements of Table 1. Table 1 Sensory requirements Project requires test methods Color Pale yellow to amber, the light, the air for a long time Gradually turned dark brown after standing Viscous liquid state Take appropriate sample is placed in a clean, dry colorimetric tube, in natural light Under observe its color and status GB 1886.225-2016 3.2 Physical and Chemical Indicators Physical and chemical indicators should be consistent with the provisions of Table 2. Table 2. Physical and chemical indicators Item Index Test Method Ethoxyquin, w /% ≥ 98.0 Appendix A A.3 Amino benzene ether, w /% ≤ 0.2 Appendix A A.4 Lead (Pb)/(mg/kg) ≤ 2.0 GB 5009.12 Arsenic (As)/(mg/kg) ≤ 2.0 GB 5009.76 GB 1886.225-2016Appendix ATesting method A.1 General Provisions This standard reagents and water, did not indicate when the other requirements, refer to the three water analytical reagent and GB/T 6682 regulations. test Test used in the standard solution, determination of impurities standard solution, preparations and products, did not indicate when the other requirements, according to GB/T 601, GB/T 602 and GB/T 603 provisions prepared. Solution was used in the tests did not indicate what is formulated with solvent, it refers to an aqueous solution. A.2 Identification Test The sample 1mg dissolved in 10mL acetonitrile, and observed under ultraviolet light, it can show a strong fluorescence. A.3 Determination of Ethoxyquin A.3.1 Reagents and materials A.3.1.1 glacial acetic acid. A.3.1.2 methyl violet indicator solution. 10g/L. Weigh 1g methyl violet, dissolved in an appropriate amount of glacial acetic acid, into the 100mL flask with ice Acetic acid volume. A.3.1.3 perchloric acid standard titration solution. c (HClO4) = 0.1mol/L. A.3.1.4 acetic anhydride. A.3.2 Analysis step Weigh about 0.2g sample, accurate to 0.0001g, placed in a clean, dry conical flask, 50mL glacial acetic acid to dissolve, plus 1mL of acetic anhydride into the mix, add 2 drops of methyl violet indicator solution, titration with perchloric acid standard solution titration to the green is the end. At the same time a blank test. A.3.3 Calculation Results Ethoxyquin mass fraction w1, according to equation (A.1) Calculated. w1 = (V-V0) × c × M 1000 × m × 100% (A.1) Where. V --- sample consumed perchloric acid standard titration solution volume in milliliters (mL); V0 --- blank test consumption volume perchloric acid standard solution, in milliliters (mL); Concentration c --- perchloric acid standard titration solution, expressed in moles per liter (mol/L); --- Ethoxyquin the M molar mass in grams per mole (g/mol) [M (C14H19NO) = 217.31]; 1000 --- volume conversion factor; M --- the quality of the sample, in grams (g). The arithmetic average of the results of two parallel determination for reporting results. Two parallel determination results is not more than 0.4% absolute difference. GB 1886.225-2016 A.4 Determination of p-aminophenyl ether A.4.1 Method summary By gas chromatography, under the selected operating conditions, so that all components have been isolated after the sample injector, detecting hydrogen flame detector, external Standard method. A.4.2 Reagents and materials A.4.2.1 ethanol. A.4.2.2 nitrogen. mass fraction ≥99.99%. A.4.2.3 diethyl phthalate internal standard solution. 100μg/mL. Weigh 1g diethyl phthalate, accurate to 0.0001g, to A small amount of anhydrous ethanol dissolved into the flask, anhydrous ethanol volume to 100mL. A.4.2.4 amino benzene ether standard solution. 10mg/mL. Weigh about 0.05g of amino benzene ether (purity ≥99%), to the nearest 0.0001g, in stoppered glass vial, was added with a pipette, take 5mL diethyl phthalate standard solution (A.4.2.3), cover Cork, shake. Sample solution A.4.2.5. 60mg/mL. Weigh about 0.3g sample, accurate to 0.0001g, in stoppered glass vial, was added with a pipette Pipette tube of 5mL diethyl phthalate standard solution (A.4.2.3), stoppered, shaken. A.4.3 Instruments and Equipment A.4.3.1 gas chromatograph. equipped with hydrogen flame ionization detector. A.4.3.2 micro syringe. A.4.4 columns and operating conditions The recommended standard chromatographic columns and the operating conditions are shown in Table A.1. Others can achieve the same degree of separation columns and chromatographic operating conditions Member may also be used. Table A.1 Recommended chromatographic columns and operating conditions Project Parameters Column 5% phenyl - methyl polysiloxane Column column diameter × length × thickness of 30m × 0.32mm × 0.25μm Column temperature/℃ Initial temperature 60 ℃, temperature rising rate of 10.0 ℃/min was raised to 200 ℃, holding 6min, And then at a rate of 20 ℃/min raised to 280 ℃, kept 10min Gasification chamber temperature/℃ 240 Detector temperature/℃ 280 Nitrogen carrier gas Flow rate/(mL/min) 40 A.4.5 Analysis step After the instrument is stable, the number of injection needles standard solution until the adjacent stable than two needle peak area analyzed in the following order. a) amino benzene ether standard solution (A.4.2.4); GB 1886.225-2016 b) the sample solution (A.4.2.5); c) sample solution (A.4.2.5); d) amino benzene ether standard solution (A.4.2.4). Injection volume are 1μL. A.4.6 Calculation Results Press a) → b) → c) → d) the order of injection, each injection peak area ratio f according to equation (A.2) Calculated. f = S1 S2 (A.2) Where. S1 --- for phenetidine peak area; S2 --- internal standard peak area. According to equation (A.2) obtained fa and fd, fb and fc are averaged, respectively, to obtain f1 and f2. Phenetidine quality scores w2, according to equation (A.3) Calculated. w2 = f1 × m1 × w f2 × m2 × 100% (A.3) Where. f1 --- phenetidine standard solution than the average of pairs of phenetidine and the internal standard peak area of; m1 --- quality of phenetidine standards, in units of grams (g); w --- to phenetidine standard mass fraction,%; f2 --- the average of the sample solution and ether ratio of amino benzene internal standard peak area of; m2 --- sample mass, in grams (g). The arithmetic average of the results of two parallel determination for reporting results. Two parallel determination results is not more than the absolute difference between the two measured 6% of the arithmetic mean value. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 1886.222-2016_English be delivered?Answer: Upon your order, we will start to translate GB 1886.222-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB 1886.222-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB 1886.222-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |