GB/T 12726.1-2013: Nuclear power plants -- Instrumentation important to safety -- Radiation monitoring for accident and post-accident conditions -- Part 1: General requirements
Status: Valid

GB/T 12726.1: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 12726.1-2013734 Add to Cart 3 days Nuclear power plants -- Instrumentation important to safety -- Radiation monitoring for accident and post-accident conditions -- Part 1: General requirements Valid
GB 12726-1991RFQ ASK 3 days Radiation monitoring equipment for accident and post-accident conditions in nuclear power plants--Part 1: General requirements Obsolete
GB/T 12726.1-1991759 Add to Cart 5 days Radiation monitoring equipment for accident and post-accident conditions in nuclear power plants--Part 1: General requirements Obsolete

Similar standards

NB/T 20015   EJ/T 350   EJ/T 306   GB/T 16702.1   GB/T 12726.4   GB/T 12726.2   

Basic data

Standard ID: GB/T 12726.1-2013 (GB/T12726.1-2013)
Description (Translated English): Nuclear power plants -- Instrumentation important to safety -- Radiation monitoring for accident and post-accident conditions -- Part 1: General requirements
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: F69
Classification of International Standard: 27.120.20
Word Count Estimation: 37,382
Older Standard (superseded by this standard): GB/T 12726.1-1991
Quoted Standard: GB/T 2423.1-2008; GB/T 2423.2-2008; GB/T 2423.3-2006; GB/T 2423.4-2008; GB/T 17626.4-2008; GB/T 17626.5-2008; GB/T 17626.8-2006; GB/T 18272.1-2000; GB/T 20138-2006; NB/T 20029-2010; ISO 2889-2010; IEC 60038-2002; IEC 60068-2-6-2007; IEC 60068-2-14-2009; I
Adopted Standard: IEC 60951-1-2009, IDT
Regulation (derived from): National Standards Bulletin No. 25 of 2013
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the general characteristics of the identification and testing of such equipment, the general test methods, radiation characteristics, electrical characteristics, environmental characteristics and safety features and equipment compl

GB/T 12726.1-2013: Nuclear power plants -- Instrumentation important to safety -- Radiation monitoring for accident and post-accident conditions -- Part 1: General requirements


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
. Nuclear power plants Instrumentation important to safety Radiation monitoring for accident and post-accident conditions Part 1. General requirements ICS 27.120.20 F69 National Standards of People's Republic of China Replacing GB/T 12726.1-1991 Nuclear power plant safety important instrument After the accident and radiation monitoring Part 1. General requirements Part 1. Generalrequirements (IEC 60951-1.2009, IDT) Issued on. 2014-08-01 2013-12-17 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ Introduction Ⅴ 1 Scope 1 2 Normative references 1 3 Terms and definitions 3 4 6 Design Principles 4.1 functions related to the basic requirements of 6 4.2 Measuring range 7 Energy response 7 4.3 4.4 The minimum detectable activity (or the detection limit) 7 4.5 precision (or repeatability) 7 4.6 accuracy (or relative error) 8 4.7 Measuring time 8 4.8 Response Time 8 4.9 overload characteristic 8 4.10 Environment The bottom shield or compensating means 8 4.11 accident conditions of claim 9 9 4.12 Reliability 4.13 User Interface 9 4.14 System Test, maintenance capabilities and ease of decontamination 11 4.15 Electromagnetic Interference 11 4.16 Power 11 4.17 interface 12 4.18 sampling device 12 13 4.19 Quality 4.20 type test reports and certification 13 5 Function test 14 5.1 Summary 14 14 5.2 General test methods 5.3 Performance Characteristics 16 5.4 Electrical Performance Test 20 22 5.5 Environmental Performance Test References 29 Table 1 SACTC30/SC2/SC3 standard series Ⅴ Table 2 Reference conditions and standard test conditions 26 Table 3 test under standard test conditions of 26 Table 4 changes affect the amount of test 27

Foreword

GB/T 12726 "after the nuclear power plant safety is important instruments accident and radiation monitoring" is divided into four parts. --- Part 1. General requirements; --- Part 2. gaseous effluents and ventilation equipment for continuous monitoring of radioactivity in the offline; --- Part 3. High range area γ continuous monitoring equipment; --- Part 4. Process flow tube or inner tube beside continuous radioactivity monitoring equipment. This section GB/T Part of 112,726. This section drafted in accordance with GB/T 1.1-2009 given rules. This Part replaces GB/T 12726.1-1991 "after the nuclear power plant accident and radiation monitoring equipment Part 1. General requirements", and GB/T 12726.1-1991 main changes are as follows. --- The equipment is divided into three typical types, and clearly the responsibility of the user and the manufacturer; --- Remove the equipment in the "post-accident conditions satisfactory 100d run over," the requirements of IEC 61226 is required to draw Class A is divided into the implementation of Security important functions equipment, in addition to be calculated MTBF external failure modes and effects analysis should be carried out (FMEA); --- Clear electromagnetic interference requirements and performance standards; --- A detailed description of the user interface, the interface device and sampling requirements; --- A clear increase in quality requirements; --- Remove the pump maintenance interval requirements; --- Revised standard test conditions, increase traffic conditions, reduce warm-up time; --- Test requirements under standard test conditions made a comprehensive revision. This section uses the translation method is equivalent to using IEC 60951-1. Radiation monitoring after 2009 "Instrumentation important to safety of nuclear power plants for accident and Part 1. General requirements. " Consistency correspondence between this part of international documents and normative references of our files are as follows. --- GB/T 156-2007 standard voltage (IEC 60038.2002, MOD); --- GB/T 2423.10-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Fc Vibration (sinusoidal) (IEC 60068-2-6.1995, IDT); --- GB/T 2423.34-2005 Environmental testing for electric and electronic products Part 2. Test methods - Test Z/AD. temperature/wet Of the combined cycle test (IEC 60068-2-38. 1974, IDT); --- GB 4208-2008 housing protection (IP Code) (IEC 60529.2001, IDT); --- GB/T 12727-2002 nuclear power plant safety systems of electrical equipment qualification (IEC 60780.1998, MOD); --- GB/T 13625-1992 nuclear power plant safety systems seismic qualification of electrical equipment (IEC 60980. 1989, eqv); --- GB/T 15474-2010 nuclear power plant instrumentation and control functions important to safety classification (IEC 61226.2005, MOD); --- GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test (IEC 61000-4-2. 2001, IDT); --- GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques RFEMS test (IEC 61000-4-3.2002, IDT); --- GB/T 17626.6-2008 Electromagnetic compatibility - Testing and measurement techniques Immunity to conducted disturbances induced field (IEC 61000-4-6.2006, IDT); --- GB 17799.4-2012 Electromagnetic compatibility - Generic emission standard for industrial environments (IEC 61000-6-4.2011, IDT); --- EJ/T 529-1990 for nuclear power plant systems important to safety digital computer (IEC 60987. 1989, eqv); --- NB/T 20054-2011 nuclear power plant safety instrumentation and control systems important to perform the function of computer software class A (IEC 60880.2006, MOD); --- NB/T 20055-2011 nuclear power plant safety instrumentation and control systems important to perform class B and class C function computer software (IEC 62138.2004, MOD). For ease of use, this section made the following editorial changes. --- Delete foreword international standards; "." --- With a decimal point instead of the original international standard as the decimal point, ""; --- Will be in "2 Normative references" existing national standards and industry standards relevant international standards to our standards; --- Will be in "2 Normative references" "IEC 61000-4-12.2006" is amended as "IEC 61000-4-18.2006"; --- ISO 2889 version of 2010's by 2009 as amended; --- In 5.3.1.1, the last sentence of paragraph 1 of the "reference response uncertainty" is corrected to "reference source of uncertainty"; --- Retain only the contents of the current used in the voltage and frequency of the AC power; --- In 4.18, delete the words "the application of the kinetic energy of the aerosol or iodine sampling head for sampling" content, and because it requires a ISO 2889.2010 requirements are different; --- IEC standard 5.3.6.2, it should be the first one for the segment of the contents of paragraph 2 of 2 "in order to obtain independent data", now Move it to the first one. This part of the National Nuclear Instrument Standardization Technical Committee (SAC/TC30) and focal points. This section is drafted. Shanghai Nuclear Engineering Research and Design Institute. The main drafters of this section. Fu Xi, Zhou. GB/T 12726.1 first released in February 1991.

Introduction

a) standard technical background, major publications and organizations This section focuses specifically on accident and after the accident radiation monitoring system in use. The series of standards for user to a specific plant radiation monitoring system technical requirements, the manufacturer may be used in the series of standards Determine the product characteristics required for the development of accident conditions of the system. Some detailed characteristics of the instrument, such as measuring range, in response to the energy and environmental conditions Pieces shall be determined according to the specific application. In this case, the standard specifies only specific request, but does not claim itself will be described. This section is important to safety after the accident radiation monitoring instruments in a standard series of standards. This series of standards consists of the following components. --- GB/T 12726.1 important instrument for nuclear power plants accident and after the accident radiation monitoring - Part 1. General requirements --- GB/T 12726.2 important to safety of nuclear power plants after the accident and radiation monitoring instrumentation - Part 2. gaseous exhaust stream and pass Wind Equipment for continuous monitoring of radioactivity in the offline (GB/T 12726.2-2013, IEC 60951-2.2009, IDT) --- GB/T 12726.3 important to safety of nuclear power plants after the accident and radiation monitoring instruments - Part 3. High range area γ even Continued monitoring device (GB/T 12726.3-2013, IEC 60951-3.2009, IDT) --- GB/T 12726.4 important to safety of nuclear power plants after the accident and radiation monitoring instrumentation - Part 4. inner tube or pipe flow process Equipment for continuous monitoring radioactivity next (GB/T 12726.4-2013, IEC 60951-4.2009, IDT) b) in the SAC/TC30/SC2/SC3 standard structure in the current standard status GB/T 12726 series of standards is in the third level in SC2 standard hierarchy. GB/T 12726 series of standards for use in accident And design and test conditions - radiation monitoring equipment to provide guidance after the accident. SC2 and SC3 other standards developed for use in normal operating Radiation monitoring instruments under the conditions provided guidance. GB/T 7165 series of standards for the off-line continuous monitoring of radioactivity in gaseous effluents under normal conditions It specifies the requirements for equipment. GB/T 10253 is a continuous off-line monitoring normal conditions of liquid radioactive effluents device specifies the requirements. IEC 60768 for the continuous monitoring of the normal operation and anticipated operational occurrences within the process stream or a bypass pipe radioactive device specifies the requirements. most After, ISO 2889 provides guidance for the gas and particle sampling. Table 1 shows the relationship between these different standards of radiation monitoring. Table 1 SAC/TC30/SC2/SC3 standard series Organization ISO developed SC2- process and safety monitoring After sampling circuit and a range of methods for accident and normal conditions and anticipated operational occurrences SC3- and radiation protection Effluent monitors Zone sampling gases, particulates and Iodine monitoring (offline) ISO 2889 GB/T 12726.1 and GB/T 12726.2 GB/T 7165 series of standards Monitor with a liquid sample (from line) NA NA GB/T 10253 Without sampling (gaseous discharge Flow, steam or liquid) process Flow monitor (next to the pipe or tube) Not applicable GB/T 12726.1 and GB/T 12726.4 IEC 60768 is not applicable Regional monitoring does not apply GB/T 12726.1 and GB/T 12726.3 GB/T 14054 The central control system is not applicable IEC 61504 IEC 61559 series of standards For details, see d SC2 series standard configuration). c) The application of this series of standards and recommendations restrictions Special attention in this series of standards does not establish additional functional requirements for the safety systems. Relations d) SC2/SC3 standard describe the structure of the series and with other standards and other bodies (IAEA, ISO ) file Top standard SC2 standard series is NB/T 20026. It is important for the implementation of nuclear power plant safety functions and instrumentation and control systems set up Preparation of the provisions of the general requirements. NB/T 20026 standard series built SC2. NB/T 20026 standard SC2 direct reference to the other, to the functional classification and grading systems, qualification, system isolation, Common Cause Fault defense, computer-based software systems, hardware-based computer systems and control room design and other aspects. Should be considered in the second layer Face direct reference to these standards and with the NB/T 20026 together as a reference document. In the third level, not NB/T 20026 directly referenced SC2/SC3 standard relates to special equipment, technical methods, or specific living Moving standard. In general, it refers to the second-level files These files can be its own reference. Expanded technical report SC2/SC3 standard series, the fourth dimension is not part of the scope of standardization. NB/T 20026 and basic safety publications have adopted similar representation formats. IEC 61508 series of standards including the overall security architecture and life cycle system life cycle provides a general framework for the nuclear power sector Description of requirements (IEC 61508.1, IEC 61508.2 and IEC 61508.4). Since the nuclear industry has to explain, in line with NB/T 20026 will facilitate the IEC 61508 series of standards consistent with the requirements. In this framework, nuclear applications sector and IEC 60880 IEC 62138 correspond to IEC 61508.3. NB/T 20026 quality assurance (QA) aspects of reference GB/T 19000-2008, GB/T 19001-2008 and HAF003 (Corresponding to IAEA50-C-QA, IAEA50-C-QA now IAEAGS-R-3-substituted). SC2 and consistent implementation of the standard series detailing the principles and basic safety considerations for nuclear safety and nuclear safety regulations guide nuclear power plant, Especially HAF102 requirements, the establishment of nuclear power plant design and safety guide HAD102/14 relates to the safety of nuclear power plants and important instrument Control systems related to safety requirements. SC2 standard uses of nuclear safety regulations and nuclear safety guidelines consistent terminology and definitions. Nuclear power plant safety important instrument After the accident and radiation monitoring Part 1. General requirements

1 Scope

This section GB/T 12726 gives the nuclear power plant accident and post-accident radiation and fluid (gas or liquid) level of radioactivity monitoring equipment The general requirements, including design principles and performance criteria. This section applies only to accidents and post-accident radiological continuous monitoring equipment. The purpose of this section is to give the general requirements for light water reactors and nuclear power plant accident and regulations to be followed by continuous monitoring of radioactivity after setting Examples of preparation methods and acceptance. This section provides the general characteristics of such equipment, general test methods, radiation characteristics, electrical characteristics, and environmental characteristics and safety features Identification and testing equipment clearances. If the device is part of the nuclear facilities on a continuous radiation monitoring system, you may need to increase the Other standards-related system. Sampling and laboratory analysis of samples is a part of the discharge stream monitor the overall outline of the scope of this section.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2423.1-2008 Environmental testing for electric and electronic products Part 2. Test methods Test A. Cold (IEC 60068-2- 1.2007, IDT) GB/T 2423.2-2008 Environmental testing for electric and electronic products Part 2. Test methods Test B. Dry heat (IEC 60068-2- 2.2007, IDT) GB/T 2423.3-2006 Environmental testing for electric and electronic products Part 2. Test methods - Test Cab. Damp heat test (IEC 60068-2-78.2001, IDT) GB/T 2423.4-2008 Environmental testing for electric and electronic products Part 2. Test methods - Test Db. Damp heat (12h 12h cycle) (IEC 60068-2-30.2005, IDT) GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity test (IEC 61000- 4-4.2004, IDT) GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge (impact) immunity test (IEC 61000-4-5. 2005, IDT) GB/T 17626.8-2006 Electromagnetic compatibility - Testing and measurement techniques - Power frequency magnetic field immunity test (IEC 61000-4-8.2001, IDT) GB/T 18272.1-2000 industrial process measurement and control system evaluation assessment - Part 1 System features. General and methods Studies (IEC 61069-1.1991, IDT) GB/T 20138-2006 electrical equipment enclosures against external mechanical impact protection rating (IK Code) (IEC 62262.2002, IDT) NB/T 20029-2010 nuclear power plant instrumentation and control systems important to safety plant radiation monitoring (IEC 61504.2000, IDT) ISO 2889.2010 Nuclear facilities chimneys and ventilation ducts airborne radioactive material sampling (Samplingairborneradioactive
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 12726.1-2013_English be delivered?

Answer: Upon your order, we will start to translate GB/T 12726.1-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 12726.1-2013_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 12726.1-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 12726.1-2013?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 12726.1-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.