HJ 659-2013 English PDFUS$419.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. HJ 659-2013: Water quality. Determination of cyanide and others by vaccum testing tube-electric colorimeter Status: Valid
Basic dataStandard ID: HJ 659-2013 (HJ659-2013)Description (Translated English): Water quality. Determination of cyanide and others by vaccum testing tube-electric colorimeter Sector / Industry: Environmental Protection Industry Standard Word Count Estimation: 16,161 Quoted Standard: HJ 589; HJ/T 91; HJ/T 164 Regulation (derived from): Department of Environmental Protection Bulletin 2013 No. 55 Issuing agency(ies): Ministry of Ecology and Environment Summary: This standard specifies: Determination of cyanide in water, fluoride, sulfide, divalent manganese, chromium, nickel, ammonia, aniline, nitrate, nitrite nitrogen, phosphate and chemical oxygen demand and other pollutants Vacuum test tube Electronic colorim HJ 659-2013: Water quality. Determination of cyanide and others by vaccum testing tube-electric colorimeter---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Water quality.Determination of cyanide and others by vaccum testing tube-electric colorimeter National Environmental Protection Standard of the People's Republic Determination of water quality cyanide, etc. Vacuum test tube - Electronic colorimetry Water quality Determination of cyanide and others by vaccum testing tube- Electric colorimeter 2 0 1 3 - 0 9 - 1 8 Release 2 0 1 3 - 0 9 - 2 0 Implementation Ministry of Environmental Protection released ContentForeword.I 1 Scope 1 2 Normative references 1 3 Terms and definitions. 2 4 Principle of the method 2 5 interference and elimination. 2 6 reagents and materials. 2 7 instruments and equipment.2 8 samples.3 9 Analysis step 3 10 result calculation and representation..4 11 Precision and Accuracy..4 12 Quality Assurance and Quality Control..4 13 Notes. 4 14. Waste treatment.5 Appendix A ..6 Appendix B.11 Appendix C.13ForewordTo implement the Environmental Protection Law of the People's Republic of China and the Law of the People's Republic of China on Water Pollution Prevention and Control, to protect the environment, This standard is formulated to ensure human health, standardize China's water environment monitoring methods, and meet the needs of water quality emergency monitoring work. This standard specifies the determination of cyanide, fluoride, sulfide, divalent manganese, hexavalent chromium, nickel, ammonia nitrogen, aniline, Vacuum test tube method for contaminants such as nitrate nitrogen, nitrite nitrogen, phosphate and chemical oxygen demand. This standard is the first release. Appendix A of this standard is a normative appendix, Appendix B and Appendix C are informative appendices. This standard was formulated by the Science and Technology Standards Department of the Ministry of Environmental Protection. This standard is mainly drafted by. Henan Environmental Monitoring Center. This standard was approved by the Ministry of Environmental Protection on September 18,.2013. This standard has been implemented since September 20,.2013. This standard is explained by the Ministry of Environmental Protection. Determination of water quality cyanide, etc. Vacuum test tube - electronic colorimetry1 Scope of applicationThis standard specifies the determination of cyanide, fluoride, sulfide, divalent manganese, hexavalent chromium, nickel, ammonia nitrogen, aniline, Vacuum test tube method for contaminants such as nitrate nitrogen, nitrite nitrogen, phosphate and chemical oxygen demand. This standard applies to cyanide, fluoride, sulfide, bivalent in groundwater, surface water, domestic sewage and industrial wastewater. Manganese, hexavalent chromium, nickel, ammonia nitrogen, aniline, nitrate nitrogen, nitrite nitrogen, phosphate, and chemical oxygen demand Quick analysis. Other pollutants may also be applied to this standard if they pass the verification. The verification method is shown in the informative Appendix C. The method detection limits for the target are shown in Table 1. Table 1 Detection limit of this method No. Compound name detection limit (mg/L) No. Compound name detection limit (mg/L) 1 Cyanide 0.0099 Nitrite (N) 0.03 2 Fluoride 0.5 8 Divalent manganese 0.5 3 Sulfide 0.1 9 Hexavalent Chromium 0.1 4 ammonia nitrogen 0.2 10 nickel 0.2 5 phosphate 0.05 11 aniline 0.1 6 Nitrate (N) 0.7 12 CODCr 102 Normative referencesThe contents of this standard refer to the following documents or their terms. For undated references, the valid version is appropriate. Used in this standard. HJ 589 Technical Specifications for Emergency Monitoring of Environmental Emergencies HJ/T 91 Surface Water and Wastewater Monitoring Technical Specifications HJ/T 164 Technical Specifications for Groundwater Environmental Monitoring3 Terms and definitionsThe following terms and definitions apply to this standard. 3.1 vacuum test tube vacuum test tube Made of borosilicate glass or quartz glass, with a certain degree of vacuum, built-in test reagents, automatic quantitative absorption after breaking A test tube that is subjected to a chemical color reaction with a specific reagent to be tested. 3.2 electronic colorimeter electric colorimeter The electronic colorimeter consists of a light source, a chrominance sensor, a colorimetric cell, a signal simulation system, and a display. The chrominance sensor is a signal receiver that determines the chromaticity signal of the color of the colored compound generated by a specific chemical color reaction. A quantity of analytical electronic instruments.4 Principle of the methodThe vacuum glass detecting tube sealed with the reaction reagent is broken in the water sample, and the sample is automatically metered into the tube, and the sample is in the sample. The analyte and the reagent react rapidly and quantitatively to form a colored compound, and the color value thereof is proportional to the content of the analyte. Chemically The functional relationship between the chrominance signal of the color reaction and the concentration of the analyte is stored in an electronic colorimeter, and the water is directly read after the measurement. The content of the analyte in the sample. See Appendix A for the principle of determination of each type of pollutant.5 interference and elimination5.1 Suspended matter or algae in water may interfere with the measurement, and interference can be eliminated by filtration or precipitation; In the case of the case, the interference can also be eliminated by dilution. 5.2 Determine whether the chromaticity causes interference by the result of the standard recovery test. When the color of the water sample interferes with the measurement, it is determined Interference can be eliminated by dilution if the range allows. 5.3 See Appendix A for other interference and elimination methods.6 reagents and materialsUnless otherwise stated, analytically pure reagents that meet national standards were used for the analysis. Experimental water is used without target dry Disturbed distilled or deionized water. 6.1 Special additives. solid or liquid reagents. Used to assist color reaction or eliminate interference, configuration method reference test tube use Instructions.7 Instruments and equipment7.1 Electronic colorimeter. LED or xenon lamp source, power-on stabilization time ≤ 10 seconds, sensor three primary color wavelength range. red. 580-750nm; green. 500-600nm; blue. 410-510nm; built-in working curve; power supply. 220v AC power supply, No. 5, 7th battery or dedicated power adapter; adapt to environmental conditions. temperature 0-40 ° C, maximum relative humidity 90% RH. 7.2 Vacuum test tube. high borosilicate or quartz glass material, vacuum. -100 ~ -80KPa, sealed a certain amount of reagents. shape Uniform, should be stored at normal temperature, low temperature or dark place according to the instructions during the warranty period. 7.3 Heating device. use 12v DC or 220v AC power supply, the temperature is set to 50-150 °C continuously adjustable, temperature precision Degree ± 0.5 ° C, suitable for test tube heating design. 7.4 Common instruments and equipment used in general laboratories.8 samples8.1 Sample collection Samples were collected in accordance with the relevant regulations of HJ/T 91, HJ/T 164 and HJ 589. 8.2 Preservation of samples Samples should be measured on-site as soon as possible without the need for a fixative.9 Analysis steps9.1 Sample Pretreatment Determine the pH of the water sample before testing and adjust to the pH range required for the measurement according to the instructions. 9.2 Commissioning Turn on the electronic colorimeter (7.1), select the parameters, adjust to the zero calibration interface, first zero, then adjust to the test state for use. When testing items such as chemical oxygen demand, sulfides, and cyanide that require heating, adjust the heating unit to the instructions. The specified heating temperature is reserved. 9.3 Direct color measurement method (hexavalent chromium, divalent manganese, ammonia nitrogen, nitrite nitrogen, nitrate nitrogen) 9.3.1 Sampling reaction Add an appropriate amount of sample to the beaker (50ml, 100ml or.200ml) and complete the capillary section of the vacuum test tube (7.2). Insert into the liquid surface, use the special tool equipped to break the front end capillary under the sample liquid level, and the negative pressure inside the tube will immediately set the sample. The amount is in the suction tube. The inhalation time takes about 1 to 5 seconds, until the liquid in the tube is full, leaving only a bubble space of about 4~8 mm in diameter. Then take out the detection tube and invert it up and down several times to move the bubbles in the tube up and down to make the liquid react evenly. Different varieties of testing The tube reaction time is different, and the instrument manual should be strictly referred to. Note 1. When the vacuum test tube is broken, observe whether there is a situation where the break position is too high or the reagent inside the tube overflows. If so, resample the sample. test. 9.3.2 Colorimetric The vacuum detection tube (7.2) after the reaction was inserted into an electron colorimeter (7.1) cuvette, and the measurement result was directly read. 9.4 Determination of heating reaction (chemical oxygen demand, sulfide, cyanide) Follow the instructions in 9.3.1 to allow the water sample to enter the vacuum detection tube (7.2). After removal, turn it back and forth several times to mix the liquid in the tube. Evenly. Then, it is placed in a preheated heating device (7.3), and the reaction temperature and time are controlled according to the instructions. Chemical need Oxygen and sulfide tests are required to be measured after room temperature. Cyanide is required to be tested immediately after heating reaction. The letter is required to proceed. Then perform colorimetric according to 9.3.2. 9.5 Determination of additive reaction (phosphate, nickel, fluoride, aniline) Accurately measure 20.0ml of water in a 50ml beaker and add appropriate amount of special additives (6.1) according to the instructions. The test parameters correspond to different auxiliaries and different addition amounts, refer to the instrument manual), mix well, do not need heating Follow the instructions in 9.3; follow the instructions in 9.4 for heating. Note 2. Before the above three different methods are measured, please clean the outer wall of the vacuum test tube with filter paper or lens paper to prevent the vacuum test tube. Contamination of the outer wall interferes with the measurement results while preventing smudging corrosion of the electronic colorimeter device. 9.6 Blank experiment Use the test water instead of the water sample to carry out the blank sample determination according to the procedure of 9.3 or 9.4 or 9.5 sample determination. 10 Calculation and representation of results The results were read directly by an electronic colorimeter in mg/L. The effective number is retained to the lower limit of quantitation, chemical needs The amount of oxygen is taken as an integer. 11 Precision and accuracy 11.1 Precision Six parallel determinations of low, medium and high blank spiked samples were performed in the laboratory to determine the target The relative standard deviations are all in the range of 0 to 30%. See Appendix B for details. 11.2 Accuracy Three concentrations of the actual samples of surface water, domestic sewage and industrial wastewater were measured in the laboratory, and the standard was added for recovery. The rate is 76% to 125%. See Appendix B for details. 12 Quality Assurance and Quality Control 12.1 Check the instrument and test tube regularly according to the requirements of the instrument manual. If the instrument manual does not stipulate, at least half a year. Check once. Instrument and test tube accuracy check method. configure the calibration solution of 0.1C, 0.5C and 0.9C concentration, when measuring the knot If the relative error is greater than 20%, the instrument and the test tube should be sent back to the manufacturer for inspection at the same time. Calibration or void detection tube for the quantitative curve. Note. C in 0.1C, 0.5C, and 0.9C refers to the highest concentration value of the instrument's quantitative curve. 12.2 Each batch of samples should be synchronized to make a full program blank, the measurement result should be lower than the method detection limit, otherwise the vacuum test should be checked. tube. 12.3 Each sample shall be tested as a pair of parallel samples with a relative deviation of less than 20%. 12.4 Each batch of samples shall be simultaneously tested in parallel with a certified reference material or standard sample to verify the accuracy. The relative error should be less than 25%. 12.5 Each sample should be synchronized to a standard sample with a spiked amount of 0.5C, and the recovery rate should be 70% to 130%. The limit data measurement result is invalid. 12.6 When the results are reported, the quality control data of the same batch analysis should be given at the same time, indicating the method detection limit. 13 Precautions 13.1 Test tubes and special additives should be stored under specified conditions and used during the warranty period. 13.2 Select the appropriate test tube according to the purpose of the test and the condition of the water sample. 13.3 When using the glass test tube, care should be taken to protect the eyes and face from splashing of the additive or scratching of the glass. 14. Waste treatment The used test tubes are safely disposed of in laboratory waste.Appendix A(normative appendix) First, the principle of the method, interference and elimination, and precautions A.1 Cyanide A.1.1 Principle of the method Cyanide (CN-) and organic ketone test solution are heated in the presence of sodium carbonate, and yellow to deep red is formed by ion association reaction. The color complex has a linear relationship between the color value of the colored complex and the concentration of cyanide. A.1.2 Interference and elimination a) S2- ≤ 30mg/L, acetone ≤ 5000mg/L does not interfere; b) NH3-N≤30mg/L does not interfere, and >30mg/L is negative interference. A.1.3 pH and reaction time The water sample to be tested should be controlled to have a pH of ≥ 4, and the reaction time of heating at 50 ° C for 10 minutes. A.1.4 Precautions a) The time during which the test tube is placed in the heated reactor shall be strictly consistent with the specified time, otherwise the reading may be in error; b) If the test tube inhales the sample and begins to show a color reaction without heating, indicating that the cyanide concentration in the sample is too high, It should be diluted after appropriate dilution. A.2 Fluoride A.2.1 Principle of the method Fluoride (F-) and hydroxy hydrazine test solution react in the presence of hydrazine to form a blue to rose red colored complex, colored network The chroma value of the compound has a linear relationship with the concentration of fluoride. A.2.2 Interference and elimination a) Cl-≤1000mg/L, NO2 -≤100mg/L, Ca2 ≤80mg/L, SO42-≤300mg/L, NO3-≤150mg/L Does not interfere with the determination; b) Cu2, Cr6, Pb2 >3.0mg/L, Mn2 >2.0mg/L, Ni2, Hg2 >5.0mg/L, PO43 >30mg/L There is interference, and the interference can be removed by distillation. A.2.3 pH and reaction time The pH of the water sample to be tested should be controlled at ≤ 8. The reaction time is 2 to 3 minutes. A.2.4 Precautions The amount of special fluorine auxiliary added has a great influence on the color tone of the display. The sample volume and special fluorine assist should be strictly controlled according to the instructions. The amount of agent added. A.3 Sulfide A.3.1 Principle of the method Sulfide reacts with N,N-dimethyl-p-phenylenediamine and high-iron under acidic conditions to form a methylene blue colored complex. The color value of the colored complex has a linear relationship with the concentration of the sulfide. A.3.2 Interference and elimination a) SO32-, S2O32-≤20mg/L, NO2-≤15mg/L, CN-< 7mg/L does not interfere; b) Negative interference when NO2-≥16mg/L, if the color is greener when tested, not methylene blue, consider NO2- Interference c) The color of the display will decrease when S2-≥20mg/L in the sample, and the appropriate multiple should be diluted before measurement. A.3.3 pH and reaction time The pH value of the water sample to be tested should be controlled at ≤9.50±1°C for accurate heating for 2 minutes, and tested at room temperature for 1 minute. A.3.4 Precautions a) Determine if the sulfide concentration is too high and test it by quantitative dilution. If the test results are straight after dilution If the test result is not quantitative, the former sulfide concentration is too high; b) The color development speed of the detection tube is related to the temperature of the water sample to be tested. For the water sample to be tested at 40~60 °C, it can be displayed within 2 minutes. The color is complete; the color development is complete at 5 minutes at room temperature of 20~30 °C. For winter low temperature samples to be tested, the device should be heated at 50 ± 1 °C. Place color in the middle to ensure complete color development. c) The pH of the water sample to be tested should be controlled below 9 because the sample will react violently with the reagent when the alkalinity is too high. At this point, the test solution easily rushes out of the test tube and causes a large error in the test result. A.4 nitrate nitrogen A.4.1 Principle of the method Nitrate reacts with 2,6-dimethylphenol under acidic conditions to form yellow 4-nitro-2,6-dimethylphenol, the yellow The color value of the color compound has a linear relationship with the concentration of nitrate nitrogen. A.4.2 Interference and elimination a) Positive interference when NO2-≥3.0 mg/L, can be eliminated by adding sulfamic acid; b) There is no interference when Cl-< 500mg/L, and positive interference when -≥500 mg/L, it can be removed by adding silver sulfate precipitation. A.4.3 pH and reaction time The coloration reaction of the detection tube is taken out when the temperature is accurately heated at 100±1 ° C for 10 minutes, and can be tested after being placed at room temperature. anti- There is no need to adjust the pH before the water sample. A.4.3 Precautions a) A strong heat release will occur after the test tube inhales the water sample. It is recommended to wear rubber gloves to protect the operation. b) If the salt is too high, there will be a lot of turbidity when the water sample is to be tested, and shake it for 20 minutes or more. The turbidity is clarified to the bottom and read again. A.5 nitrite nitrogen A.5.1 Principle of the method Nitrite and quinone imine dye test solution react under acidic conditions to form a blue-violet complex, the color of the complex The value has a linear relationship with the concentration of nitrite nitrogen. A.5.2 Interference and elimination a) No interference when sodium thiosulfate is ≤7.5mg/L, and positive interference when >7.5 mg/L; b) Ca2 and Mg2 ≤1,000mg/L, and Ni2 and Cr6 ≤50mg/L do not interfere; A.5.3 pH and reaction time When acc......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of HJ 659-2013_English be delivered?Answer: Upon your order, we will start to translate HJ 659-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of HJ 659-2013_English with my colleagues?Answer: Yes. The purchased PDF of HJ 659-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |