YY/T 1538-2017: Auto-scanning water phantom system in radiation therapy - Functional-performance characteristics and test methods
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
YY/T 1538-2017150 Add to Cart Auto, 9 seconds. Auto-scanning water phantom system in radiation therapy - Functional-performance characteristics and test methods Valid

Similar standards

YY/T 1694   YY/T 1711   YY/T 1537   YY/T 1541   

YY/T 1538-2017: Auto-scanning water phantom system in radiation therapy - Functional-performance characteristics and test methods


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YYT1538-2017
YY PHARMACUETICAL INDUSTRY STANDARD ICS 11.040.60 C 43 Auto-scanning water phantom system in radiation therapy - Functional-performance characteristics and test methods Issued on. MAY 2, 2017 Implemented on. APRIL 1, 2018 Issued by. China Food and Drug Administration

Table of Contents

Foreword... 3 1 Scope... 4 2 Normative References... 4 3 Terms and Definitions... 4 4 Requirements... 5 4.1 Accompanying documents... 5 4.2 Positioning accuracy... 6 4.3 Positioning repeatability... 6 4.4 Verticality of each axis... 6 4.5 Sampling-point density... 6 4.6 Requirements of radiation measurement unit... 6 4.7 Software functions... 7 5 Test methods... 7 5.1 Accompanying documents... 7 5.2 Positioning accuracy... 7 5.3 Positioning repeatability... 8 5.4 Verticality of each axis... 8 5.5 Density of sampling point... 8 5.6 Requirements of radiation measurement unit... 9 5.7 Software function... 9

Foreword

This Standard was drafted in accordance with the rules given in GB/T 1.1-2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuer of this document shall not be held responsible for identifying any or all such patent rights. This Standard was proposed by China Food and Drug Administration. This Standard shall be under the jurisdiction of National Technical Committee on Medical Electrical Appliances Standardization, Sub-technical Committee on Radiotherapy, Nuclear Medicine and Radiation Dosimetry Equipment (SAC/TC 10/SC 3). The drafting organizations of this Standard. Beijing Medical Device Testing Institute, China Institute of Metrology, Zhejiang Institute of Metrology, China Test Technology Research Institute, Shanghai Lianying Medical Technology Co., Ltd., PLA General Hospital of Beijing Military Region, Chinese Academy of Medical Sciences Cancer Hospital. The main drafters of this Standard. Zhang Xin, Zhang Hui, Chen Can, Huang Yang, Li Gui, Zhang Fuli, Miao Junjie. Auto-scanning water phantom system in radiation therapy - Functional-performance characteristics and test methods

1 Scope

This standard specifies the functional-performance requirements and test methods for automatic scanning water phantom system for radiotherapy. The system, by moving the detector, realizes the automatic measurement of radiation dose distribution for radiotherapy. This standard applies only to one-dimensional, two-dimensional, three-dimensional auto-scanning water phantom system for radiotherapy.

2 Normative References

The following referenced documents are indispensable for the application of this document. For dated references, only the edition dated applies to this document. For undated references, the latest edition of the referenced documents (including all amendments) applies to This Standard. GB/T 17857, Medical radiology - Terminology (Equipment for radiotherapy, nuclear medicine and radiation dosimetry)

3 Terms and Definitions

Those defined in GB/T 17857 and YY/T 0976-2016 AND the following terms and definitions apply to this document. 3.1 Automatic scanning water phantom system Automatic scanning water phantom system (also known as scanning water tank, hereinafter referred to as the system) is an ionizing radiation measuring system in the field of radiation therapy, which automatically measures the radiation dose distribution by moving the detector. 3.2 System coordinate system The coordinate system given by each axis of the system. The zero point generally goes over the beam axis AND points out the direction. 3.4 Reference detector The detector that is fixed, in the measured radiation field, at position where the disturbance to measurement is minimum; it is used to eliminate the influence of measurement results by the fluctuation of measured radiation beam. The detector can be an ionization chamber or a semiconductor.

4 Requirements

4.1 Accompanying documents Accompanying documents shall contain, at least, the following content. 4.2 Positioning accuracy The error that the detector reaches the specified position, along each axis, shall not exceed 0.2mm. 4.3 Positioning repeatability After the detector repeatedly reaches the designated position, along each axis, the repeatability of returning to the initial position shall not exceed 0.1mm. 4.4 Verticality of each axis When the travel-range is less than or equal to 200mm, the deviation between the travel-direction axis and the reference straight-line of other axes shall not exceed 0.5mm. 4.7 Software functions The software shall include, at least, the following functions.

5 Test methods

5.1 Accompanying documents Check accompanying documents. It shall meet the requirements of 4.1. 5.2 Positioning accuracy When the system works under normal conditions, follow the methods below. 5.3 Positioning repeatability When the system works under normal use-conditions, follow the methods below. Manipulate the moving components in each direction; move to the following specified positions. 5.4 Verticality of each axis When the system works under normal use-conditions, follow the methods below. Manipulate the moving components in each direction; move to the following specified positions. 5.5 Density of sampling point Start automatic scanning water phantom system for radiotherapy; for function checking, it shall meet the requirements of 4.5. 5.6 Requirements of radiation measurement unit The method is as follows. ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of YY/T 1538-2017 be delivered?Answer: The full copy PDF of English version of YY/T 1538-2017 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of YY/T 1538-2017_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 1538-2017_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- YY/T 1538-2017 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of YY/T 1538-2017?

A step-by-step guide to download PDF of YY/T 1538-2017_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "YY/T 1538-2017".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9