YY/T 0922-2014: Medical Endoscopes - Endoscope Accessories - Bridges
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
YY/T 0922-2014150 Add to Cart Auto, 9 seconds. Medical Endoscopes - Endoscope Accessories - Bridges Valid

Similar standards

YY/T 0931   YY/T 0932   YY/T 0940   YY/T 0930   

YY/T 0922-2014: Medical Endoscopes - Endoscope Accessories - Bridges

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YYT0922-2014
YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.99 C 40 Medical Endoscopes - Endoscope Accessories - Bridges ISSUED ON: JUNE 17, 2014 IMPLEMENTED ON: JULY 1, 2015 Issued by: China Food and Drug Administration

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative References ... 4 3 Terms and Definitions ... 4 4 Requirements... 5 5 Test Methods ... 8 6 Inspection Rules ... 10 Medical Endoscopes - Endoscope Accessories - Bridges

1 Scope

This Standard specifies the terms, definitions, requirements and test methods of bridges. This Standard is applicable to bridges, which are used for endoscope import for medical purposes.

2 Normative References

The following documents are indispensable to the application of this Standard. In terms of references with a specified date, only versions with a specified date are applicable to this Standard. In terms of references without a specified date, the latest version (including all the modifications) of is applicable to this Standard. GB/T 14233.1-2008 Test Methods for Infusion, Transfusion, Injection Equipment for Medical Use - Part 1: Chemical Analysis Methods GB/T 14233.2-2005 Test Methods for Infusion, Transfusion, Injection Equipment for Medical Use - Part 2: Biological Test Methods GB/T 16886.1 Biological Evaluation of Medical Devices - Part 1: Evaluation and Testing within a Risk Management Process YY/T 0149-2006 Medical Instruments of Stainless Steel - Test Methods of Corrosion Resistance

3 Terms and Definitions

The following terms and definitions are applicable to this Standard. 3.1 Endoscope Accessory Endoscope accessory refers to accessory, which are indispensable to and/or suitable for endoscope to implement the expected purposes of endoscope; or make it convenient for the implementation of the expected purposes of endoscope; or improve the expected purposes of endoscope; or increase the additional functions of endoscope. shall prevail in all the tests. In terms of materials which have already been proved to be applicable, if it can be proved that the subsequent manufacturing process of the materials would not generate biosafety hazards, repeated biological tests may be unnecessary. NOTE 1: in design, if instrument materials have demonstrable history of usage in specific application, or relevant material and/or instrument information may be obtained from other aspects, then, it may be believed that the materials have already been proved to be applicable before. NOTE 2: in terms of metal materials, if medical metal materials with an applicable range of application in national or industrial standards are adopted, repeated biological tests may be unnecessary. 4.2 Dimensions 4.2.1 Total length The nominal value tolerance of the total length of bridge shall be: ± 3% or 1 mm. 4.2.2 Minimum main channel width The minimum width of main channel shall be not less than the nominal value. 4.3 Coordination 4.3.1 Locking, inserting and disassembly Locking (if it is equipped with a locker), inserting and disassembly, which are jointly coordinated by bridge, sheath, endoscope or obturator, shall comply with the following requirements: a) After the coordination, it shall be able to be locked; the locking shall be reliable; b) Inserting shall be relaxing; disassembly shall be relaxing and convenient. 4.3.2 Positioning and sealing After the joint coordination of bridge, sheath or endoscope, it shall satisfy the following requirements: a) After it is properly inserted, the positioning shall be reliable; there shall be no loosening; b) Except when the manufacturer claims that there is no requirement for sealing, after it is properly inserted, it shall be properly sealed. In water permeability test, within 1 min, permeated water shall not exceed 5 drops. 4.8.1 Sterility If bridges are disposable, they shall be sterile. 4.8.2 Ethylene oxide residue If the disposable bridges adopt ethylene oxide for sterilization, ethylene oxide residue shall be not more than 10 μg/g.

5 Test Methods

5.1 Materials 5.1.1 Chemical composition of metal materials Chemical composition of metal materials shall be tested through the method of appropriate precision. 5.1.2 Biocompatibility It is recommended that biological tests shall adopt relevant parts in GB/T 16886. 5.2 Dimensional Measurement 5.2.1 Equipment Standard measuring tools, measuring instruments or other tools with equivalent precision shall be adopted for measurement test. 5.2.2 Environmental conditions Room temperature: 23 °C ± 5 °C. 5.2.3 Procedure The procedure of measurement shall comply with routine methods. 5.3 Inspection of Coordination 5.3.1 Locking, inserting and disassembly test 5.3.1.1 Equipment Standard dynamometer or other equivalent tools. 5.3.1.2 Environmental conditions The test shall be conducted under room temperature. ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.