Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YY/T 0908-2013 PDF English

US$105.00 · In stock · Download in 9 seconds
YY/T 0908-2013: Single-use filter for syringe
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
YY/T 0908-2013105 Add to Cart Auto, 9 seconds. Single-use filter for syringe Valid

Similar standards

YY/T 0918   YY/T 0923   YY/T 0927   YY 0329   

YY/T 0908-2013: Single-use filter for syringe

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YYT0908-2013
YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.20 C 31 Single-use filter for syringe ISSUED ON: OCTOBER 21, 2013 IMPLEMENTED ON: OCTOBER 01, 2014 Issued by: China Food and Drug Administration

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Classification and marking ... 5 4 Materials ... 6 5 Physical requirements ... 6 6 Chemical requirements ... 7 7 Biological requirements ... 8 8 Signs ... 9 9 Packaging ... 10 Annex A (Normative) Physical test ... 11 Annex B (Normative) Type inspection rules ... 15 Single-use filter for syringe

1 Scope

This Standard specifies classification and marking, materials, physical requirements, chemical requirements, biological requirements, signs, packaging for single-use filter for syringe. This Standard is applicable to single-use filter for syringe (hereinafter referred to as the filter). The filter is used in conjunction with injection equipment. It is used in intramuscular injection, intravenous injection of drugs, and adding drugs to liquid bottles in clinical treatment. It is used to filter insoluble particles in liquid medicine.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 1962.1, Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirement GB/T 1962.2, Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings GB/T 6682, Water for analytical laboratory use - Specification and test methods GB 8368, Infusion sets for single use - Gravity feed GB/T 14233.1-2008, Test methods for infusion, transfusion, injection equipment for medical use - Part 1: Chemical analysis methods GB/T 14233.2, Test methods for infusion, transfusion, injection equipment for medical use - Part 2: Biological test methods GB 15810, Sterile syringes for single use GB/T 16886.1, Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process YY 0321.3, Single-use filter for anesthesia When tested according to the indirect titration method in GB/T 14233.1-2008, the difference between the volume of the potassium permanganate solution [c(KMnO4)=0.002mol/L] consumed by the test solution and the blank solution shall not exceed 2.0mL. 6.3 Metal ion When testing according to 5.6.1 in GB/T 14233.1-2008, the color of the test solution shall not exceed the standard control solution with mass concentration of ρ(Pb2+)=1μg/mL. When testing according to atomic absorption spectrophotometry in GB/T 14233.1-2008, the content of cadmium shall not exceed 0.1μg/mL. 6.4 pH Carry out the test according to acidity meter method in GB/T 14233.1-2008, and the pH difference between the test solution and the blank solution shall not exceed 1.0. 6.5 Residual amount of ethylene oxide If ethylene oxide is used for sterilization, after the filter is sterilized, when it is tested according to GB/T 14233.1-2008, the residual amount shall not exceed 10μg/g.

7 Biological requirements

7.1 General For the filter, when new products are put into production, when material changes significantly, the biological evaluation of cytotoxicity, irritation or intradermal reaction, sensitization, acute systemic toxicity, pyrogenic reaction and hemocompatibility shall be carried out according to GB/T 16886.1. 7.2 Sterilization The filter shall be sterilized by a sterilization-validated process and routine controls. NOTE 1: See GB 18278, GB 18279 and GB 18280 for suitable sterilization confirmation and routine control. NOTE 2: Sterility test methods are specified in GB/T 14233.2. This method can be used for type test and is not suitable for factory inspection. NOTE 3: If the product is provided in a non-sterile state, it shall be clearly marked on the package that "unsterilized, not for direct clinical use". 7.3 Bacterial endotoxin When the filter is tested according to GB/T 14233.2, its content shall not exceed 20EU/piece (or piece).

8 Signs

8.1 Initial packaging The initial packaging shall contain at least the following information: a) Product name and specification marking in compliance with Chapter 3; b) Manufacturer's name and address; c) Product registration certificate number, implementation standard number; d) Use the graphic symbols given in YY/T 0466.1, indicating the filter is sterile. If the product is provided in a non-sterile state, it shall be clearly marked in red on the package: "Unsterilized, not for direct clinical use”; e) The filter is pyrogen-free; f) The filter is for one-time use only, or equivalent instructions, or use the graphic symbols given in YY/T 0466.1; g) Instructions for use, including checking the integrity of the package seal and warnings about detachment of the protective cover; h) Production batch number, beginning with the word "batch" or "LOT", or using the graphic symbols given in accordance with YY/T 0466.1; i) Expiration date, with appropriate text, or use the graphic symbols given in accordance with YY/T 0466.1; j) Label the filter nominal pore size. 8.2 Outer packaging At least the following information shall be on the outer packaging: a) Product name and specification marking in compliance with Chapter 3; b) Manufacturer's name and address; c) Use the graphic symbols given in YY/T 0466.1 to indicate that the filter is sterile. If the product is provided in a non-sterile state, it shall be clearly marked in red on the package, "Unsterilized, not for direct clinical use"; d) Lot number, beginning with the word "batch" or "LOT", or use the graphic symbols given in accordance with YY/T 0466.1; e) Expiration date, with appropriate text, or use the graphic symbols given in accordance with YY/T 0466.1; f) Recommended storage conditions, if available.

9 Packaging

9.1 Each filter shall be packaged in the primary packaging. When using ethylene oxide for sterilization, the primary packaging of the filter shall be a packaging material with one side of dialysis paper and the other side of plastic material or full dialysis paper. This Standard encourages the use of packaging materials with better dialysis effects. Packaging materials must not have a detrimental effect on the contents. The materials and design of this packaging shall ensure that: a) Under dry, clean and adequately ventilated storage conditions, the contents can be guaranteed to be sterile; b) The risk of contamination of contents is minimum when removed from packaging; c) The contents are adequately protected during normal handling, transport and storage; d) Once opened, the package cannot be easily resealed and there shall be visible signs of tearing. 9.2 One or more pieces of initial packaging shall be packed into one piece of intermediate packaging. During normal handling, transportation and storage, the middle packaging shall be able to protect the contents fully and effectively. 9.3 If the product is provided in a non-sterile state, it shall be determined by the manufacturer. ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of YY/T 0908-2013 be delivered?Answer: The full copy PDF of English version of YY/T 0908-2013 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of YY/T 0908-2013_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0908-2013_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- YY/T 0908-2013 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of YY/T 0908-2013?

A step-by-step guide to download PDF of YY/T 0908-2013_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "YY/T 0908-2013".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9