YY/T 0681.13-2014: Test methods for sterile medical device package. Part 13: Slow rate penetration resistance of flexible barrier films and laminates
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
YY/T 0681.13-2014175 Add to Cart Auto, 9 seconds. Test methods for sterile medical device package. Part 13: Slow rate penetration resistance of flexible barrier films and laminates Valid

Similar standards

YY/T 0681.12   YY/T 0681.15   YY/T 0681.14   YY/T 0681.4   

YY/T 0681.13-2014: Test methods for sterile medical device package. Part 13: Slow rate penetration resistance of flexible barrier films and laminates


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YYT0681.13-2014
PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.080.040 C 31 Test methods for sterile medical device package - Part 13: Slow rate penetration resistance of flexible barrier films and laminates ISSUED ON: JUNE 17, 2014 IMPLEMENTED ON: JULY 01, 2015 Issued by: China Food and Drug Administration

Table of Contents

Foreword ... 3 1 Scope ... 5 2 Normative references ... 5 3 Terminology ... 5 4 Significance and application ... 6 5 Instruments ... 6 6 Specimen ... 7 7 Instrument preparation ... 8 8 Number of specimens ... 8 9 State conditioning ... 8 10 Procedure ... 8 11 Report ... 9 Appendix A (Informative) Precision and bias ... 11

Foreword

YY/T 0681 “Test methods for sterile medical device package” is divided into the following parts: - Part 1: Test guide for accelerated aging; - Part 2: Seal strength of flexible battier materials; - Part 3: Internal pressurization failure resistance of unrestrained packages; - Part 4: Detecting seal leaks in porous packages by dye penetration; - Part 5: Detecting gross leaks in medical packaging by internal pressurization (bubble test) - Part 6: Evaluation of chemical resistance of printed inks and coatings on flexible packaging materials; - Part 7: Evaluating inks or coating adhesion to flexible packaging materials using tape; - Part 8: Coating/adhesive weight determination; - Part 9: Burst testing of flexible package seals using internal air pressurization weight restraining plates; - Part 10: Test for microbial barrier ranking of porous package material; - Part 11: Determining integrity of seals for medical packaging by visual inspection; - Part 12: Flex durability of flexible barrier films; - Part 13: Slow rate penetration resistance of flexible barrier films and laminates. This part is Part 13 of YY/T 0681. This part was drafted in accordance with the rules given in GB/T 1.1-2009. This part was formulated with reference to ASTM F1306-1990 "Slow rate penetration resistance of flexible barrier films and laminates". Please note that some elements of this document may involve patents. The issuer of this document is not responsible for identifying these patents. This part shall be under the jurisdiction of the National Technical Committee for Test methods for sterile medical device package - Part 13: Slow rate penetration resistance of flexible barrier films and laminates

1 Scope

This part of YY/T 0681 is applicable to determine the penetration resistance of the anti-drive probe of flexible barrier film and laminates. In this test, biaxial stress is applied to the material at a constant test rate at room temperature, until penetration occurs; the force, energy and elongation before penetration are measured. Note: Appendix A gives the precision and bias of the test methods as specified in this part.

2 Normative references

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard. GB/T 2918 Plastics - Standard atmospheres for conditioning and testing (GB/T 2918-1998, idt ISO 291:1997)

3 Terminology

The following terms and definitions apply to this document. 3.1 Elongation The elastic / plastic deformation of the driving probe when it penetrates the flexible film. 3.2 Penetration resistance 6.2 The specimen size shall be 76 mm × 76 mm.

7 Instrument preparation

7.1 Set up and operate the instrument according to the instrument’s operation manual. 7.2 Install the probe. 7.3 Place the probe above the clamp and align it.

8 Number of specimens

Test at least 5 specimens for each sample.

9 State conditioning

9.1 According to the provisions of GB/T 2918 before the test, condition the state of the specimen under the conditions of temperature (23 ± 2) °C and relative humidity (50 ± 5) % for at least 40 h. 9.2 Unless otherwise specified in this test method, the test is performed under standard laboratory conditions with a temperature of (23 ± 2) °C and a relative humidity of (50 ± 5) %.

10 Procedure

10.1 Calibrate the test instrument according to the instrument manufacturer's instructions. 10.2 Select the force of the dynamometer in the range of 20% ~ 80% of the range when penetration occurs. 10.3 Use the sample cutter to cut at least five 76 mm × 76 mm specimens for each sample. 10.4 Measure the thickness in the center of the film sample (average of 3 readings). Note 1: The thickness can be measured by ASTM D374 or GB/T 6672. It is recommended to use Method C or Method D of ASTM D374 first. Note 2: The accuracy of the thickness measurement methods in Table A.3 is based on ASTM D374.

Appendix A

(Informative) Precision and bias A.1 Precision A.1.1 Precision data Table A.1 and Table A.2 are the research results of laboratory collaborative tests conducted by ASTM on six materials in accordance with ASTM E691 in six laboratories from 1988 to 1989. All samples of each material came from the same source, but the specimens were prepared in each participating laboratory. Each test result is an independently measured test value. Each laboratory obtained 5 test results for each material. Each laboratory conducted two parallel tests on each material; treated them as independent materials. Tables A.3 and A.4 are based on the collaborative tests of the above laboratories. But the data is from 3 laboratories and 4 laboratories, respectively. When using it, it should pay attention to the relatively small amount of data. Note: The following (A.1.2) explanation of r and R is only intended to give the concept of the approximate precision of this test method. Tables A.1 and A.3 should not be strictly used for the acceptance or rejection of materials, because these data are only for the materials involved in the verification, but do not represent other batches, conditions, materials or laboratories. Users of this test method should obtain data for specific laboratories and materials or between specific laboratories. An explanation of these data is given in A.1.2. A.1.2 Concepts of r and R A.1.2.1 If Sr is obtained from enough data, the difference between the two test results obtained by the same operator, using the same equipment, and on the same day exceeds the repeatability limit (r) of the material, it should be determined that the two test results are not equivalent. A.1.2.2 If the SR is obtained from sufficient data, the two test results obtained by different operators, using different equipment, and in different laboratories for the same material exceed the material reproducibility limit (R ), it should be determined that the two test results are not equivalent. A.1.2.3 For the judgement according to A.1.2.1 and A.1.2.2, the correct probability is about 95% (0.95). A.2 Bias ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of YY/T 0681.13-2014 be delivered?Answer: The full copy PDF of English version of YY/T 0681.13-2014 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of YY/T 0681.13-2014_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0681.13-2014_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- YY/T 0681.13-2014 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of YY/T 0681.13-2014?

A step-by-step guide to download PDF of YY/T 0681.13-2014_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "YY/T 0681.13-2014".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9