YY 0290.8-2022 PDF EnglishUS$170.00 · In stock · Download in 9 seconds
YY 0290.8-2022: Ophthalmic optics - Intraocular lenses - Part 8: Fundamental requirement Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid YY 0290.8: Historical versions
Similar standardsYY 0290.8-2022: Ophthalmic optics - Intraocular lenses - Part 8: Fundamental requirement---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YY0290.8-2022YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040 CCS C 40 Replacing YY 0290.8-2008 Ophthalmic optics - Intraocular lenses - Part 8: Fundamental requirement (ISO 11979-8:2017, Ophthalmic implants - Intraocular lenses - Part 8: Fundamental requirement, MOD) ISSUED ON: OCTOBER 17, 2022 IMPLEMENTED ON: NOVEMBER 01, 2025 Issued by: National Medical Products Administration Table of ContentsForeword ... 3 1 Scope ... 6 2 Normative references ... 6 3 Terms and definitions ... 7 4 Safety and performance ... 7 5 Optical and mechanical properties ... 7 6 Biocompatibility ... 7 7 Clinical evaluation ... 7 8 Manufacturing ... 8 9 Sterilization ... 8 10 Packaging and shelf-life ... 9 11 Labeling and information ... 9 12 Documentation ... 9 References ... 10ForewordThis document was drafted in accordance with the rules provided in GB/T 1.1-2020 Directives for standardization - Part 1: Rules for the structure and drafting of standardizing documents. This document is part 8 of YY(/T) 0290 Ophthalmic optics - Intraocular lenses. The following parts have been issued for YY(/T) 0290: -- Part 1: Terminology; -- Part 2: Optical properties and test methods; -- Part 3: Mechanical properties and test methods; -- Part 4: Labeling and information; -- Part 5: Biocompatibility; -- Part 6: Shelf-life and transport stability; -- Part 8: Fundamental requirement; -- Part 9: Multifocal intraocular lenses; -- Part 10: Phakic intraocular lenses. This document serves as a replacement of YY 0290.8-2008 Ophthalmic implants - Intraocular lenses - Part 8: Fundamental requirement. In comparison with YY 0290.8- 2008, apart from structural adjustments and editorial modifications, the main technical changes are as follows: -- Modify “Normative references” (see Chapter 2; Chapter 2 of the 2008 edition); -- Modify “Safety and performance” (see Chapter 4; Chapter 4 of the 2008 edition); -- Modify “Optical and mechanical properties” (see Chapter 5; Chapter 5 of the 2008 edition); -- Modify “Biocompatibility” (see Chapter 6; Chapter 6 of the 2008 edition); -- Modify “Clinical evaluation” (see Chapter 7; Chapter 7 of the 2008 edition); -- Modify “General requirements” (see 9.1; 9.1 of the 2008 edition); -- Modify “Bacterial endotoxins” (see 9.2; 9.2 of the 2008 edition). Ophthalmic optics - Intraocular lenses - Part 8: Fundamental requirement1 ScopeThis document specifies fundamental requirements for all types of intraocular lenses intended for surgical implantation into the anterior segment of the human eye. This document does not apply to corneal implants and transplants.2 Normative referencesThe following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the version corresponding to that date is applicable to this document; for undated references, the latest version (including all amendments) is applicable to this document. YY/T 0287, Medical devices - Quality management systems - Requirements for regulatory purposes (YY/T 0287-2017, ISO 13485:2016, IDT) YY/T 0290.1, Ophthalmic optics - Intraocular lenses - Part 1: Terminology (YY/T 0290.1-2021, ISO 11979-1:2018, MOD) YY 0290.2, Ophthalmic optics - Intraocular lenses - Part 2: Optical properties and test methods (YY 0290.2-2021, ISO 11979-2:2014, MOD) YY 0290.3, Ophthalmic optics - Intraocular lenses - Part 3: Mechanical properties and test methods (YY 0290.3-2018, ISO 11979-3:2012, MOD) YY/T 0290.4, Ophthalmic optics - Intraocular lenses - Part 4: Labeling and information (YY/T 0290.4-2008, ISO 11979-4:2000, IDT) YY 0290.5, Ophthalmic implants - Intraocular lenses - Part 5: Biocompatibility (YY 0290.5-2008, ISO 11979-5:2006, MOD) YY/T 0290.6, Ophthalmic optics - Intraocular lenses - Part 6: Shelf-life and transport stability (YY/T 0290.6-2021, ISO 11979-6:2014, MOD) YY 0290.10, Intraocular lenses - Part 10: Phakic intraocular lenses (YY 0290.10- 2009, ISO 11979-10:2006, MOD) YY/T 0316, Medical devices - Application of risk management to medical devices (YY/T 0316-2016, ISO 14971:2007, rectified, IDT) YY/T 0640, Non-active surgical implants - General requirements (YY/T 0640-2016, ISO 14630:2012, IDT) Pharmacopoeia of the People’s Republic of China3 Terms and definitionsFor the purposes of this document, the terms and definitions given in YY/T 0290.1 apply.4 Safety and performanceThe safety and performance of an intraocular lens shall be demonstrated by pre-clinical and clinical evaluation, including suitable risk in accordance with YY/T 0316. In cases where a test method referenced in YY 0290 is not suitable for a certain design or a certain application, an alternative test method devised by the manufacturer shall be validated, justified and documented.5 Optical and mechanical propertiesThe manufacturer shall ensure that the intraocular lens conforms to applicable requirements in YY 0290.2, YY 0290.3 and YY 0290.10. The manufacturer shall record and justify any deviations from the above standards.6 BiocompatibilityThe manufacturer shall have documented evidence that demonstrates the intraocular lens to be biocompatible by assessment in accordance with YY 0290.5. Manufacturers can take into consideration previous experience and data when determining the extent of further biocompatibility testing.7 Clinical evaluationThe clinical evaluation shall be carried out in accordance with the relevant provisions of the clinical evaluation of medical devices in our country. Note: The first step in the clinical evaluation is a review of the available literature (published and unpublished) in order to determine if that information is sufficient to demonstrate the safety and performance of the device. One option is to demonstrate that the new intraocular lens model is a minor modification of a parent model, the safety and performance of which has previously been ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of YY 0290.8-2022 be delivered?Answer: The full copy PDF of English version of YY 0290.8-2022 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of YY 0290.8-2022_English with my colleagues?Answer: Yes. The purchased PDF of YY 0290.8-2022_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- YY 0290.8-2022 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version YY 0290.8-2022?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY 0290.8-2022 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of YY 0290.8-2022?A step-by-step guide to download PDF of YY 0290.8-2022_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "YY 0290.8-2022". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |