YY 0054-2023 PDF EnglishUS$365.00 · In stock · Download in 9 seconds
YY 0054-2023: Specification for management of ecological and environmental archives - - Ecological and environmental protection of construction project Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid YY 0054: Historical versions
Similar standardsYY 0054-2023: Specification for management of ecological and environmental archives - - Ecological and environmental protection of construction project---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YY0054-2023 YY PHARMACEUTICAL INDUSTRY STANDARD ICS 11.040.40 CCS C 45 Replacing YY/T 0054-2010 Hemodialysis Equipment Issued on. JANUARY 13, 2023 Implemented on. JANUARY 15, 2026 Issued by. National Medical Products Administration Table of ContentsForeword... 4 1 Scope... 7 2 Normative References... 7 3 Terms and Definitions... 8 4 Classification... 8 5 Requirements... 8 5.1 Normal working conditions of the equipment... 8 5.2 Flow control... 9 5.3 Dialysate composition... 11 5.4 Filtration-sterilization system... 11 5.5 Control and protection of dialysate conductivity... 12 5.6 Temperature control... 13 5.7 Pressure monitoring... 14 5.8 Dialysate flow, temperature and conductivity stability... 15 5.9 Blood leakage protection system... 15 5.10 Prevent air from entering... 15 5.11 pH measuring device... 16 5.12 Network power supply interruption... 16 5.13 Degassing function... 16 5.14 Waste liquid protection... 16 5.15 Disinfection... 16 5.16 Operating noise... 18 5.17 Appearance and structure... 18 5.18 Safety requirements... 19 5.19 Environmental test... 19 6 Test Methods... 19 6.1 Test working conditions... 19 6.2 Flow control test... 20 6.3 Dialysate composition test... 25 6.4 Filtration-sterilization system test... 25 6.5 Dialysate conductivity control and protection test... 26 6.6 Temperature control system test... 28 6.7 Pressure monitoring test... 29 6.8 Dialysate flow, temperature, conductivity stability test... 30 6.9 Blood leakage protection system test... 31 6.10 Test to prevent air from entering... 32 6.11 pH measuring device test... 33 6.12 Network power supply interruption test... 33 6.13 Degassing function test... 33 6.14 Waste liquid protection test... 33 6.15 Disinfection test... 34 6.16 Working noise test... 37 6.17 Appearance and structural testing... 37 6.18 Safety requirements test... 37 6.19 Environmental test... 37ForewordThis Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for Standardization – Part 1.Rules for the Structure and Drafting of Standardizing Documents. This Document replaced YY 0054-2010 Hemodialysis Equipment. Compared with YY 0054- 2010, this Document mad ethe major technical changes as follows besides the structural adjustments and editorial modifications. --- Change the "Scope" (see Clause 1 of this Edition; Clause 1 of the 2010 Edition); ---Change the "Normative References" (see Clause 2 of this Edition; Clause 2 of the 2010 Edition); --- Change the "Terms and Definitions" (see Clause 3 of this Edition; Clause 3 of the 2010 Edition); ---Change the "Classification and Basic Parameters" (see Clause 4 of this Edition; Clause 4 of the 2010 Edition); --- Change the requirements and test methods for "blood flow error" (see 5.2.1 and 6.2.1 of this Edition; 5.2.1 and 6.2.1 of the 2010 Edition); --- Change the requirements and test methods for "dialysate flow error" (see 5.2.2 and 6.2.2 of this Edition; 5.2.2 and 6.2.2 of the 2010 Edition); --- Change the requirements and test methods for "net dehydration control" (see 5.2.3 and 6.2.3 of this Edition; 5.2.3 and 6.2.3 of the 2010 Edition); --- Change the requirements and test methods for "replacement fluid flow error" (see 5.2.4 and 6.2.4 of this Edition; 5.2.4 and 6.2.4 of the 2010 Edition); --- Change the requirements and test methods for "control and protection of heparin pumps" (see 5.2.5 and 6.2.5 of this Edition; 5.2.5 and 6.2.5 of the 2010 Edition); --- Change the requirements and test methods for "dialysate composition" (see 5.3 and 6.3 of this Edition; 5.3 and 6.3 of the 2010 Edition); --- Change the requirements and test methods for "filtration-sterilization system" (see 5.4 and 6.4 of this Editon; 5.4 and 6.4 of the 2010 Edition); --- Change the requirements and test methods for " control and protection of dialysate conductivity " (see 5.5 and 6.5 of this Edition; 5.5 and 6.5 of the 2010 Edition); --- Change the requirements and test methods for "temperature control" (see 5.6 and 6.6 of this Edition; 5.6 and 6.6 of the 2010 Edition); --- Change the requirements for "venous pressure monitoring" (see 5.7.2 of this Edition; 5.7.2 of the 2010 Edition); --- Add the requirements and test methods for "arterial pressure alarm action" [see 5.7.3 c) of this Edition]; --- Change the requirements and test methods for "blood leakage protection system" (see 5.9 and 6.9 of this Edition; 5.9 and 6.9 of the 2010 Edition); --- Change the requirements and test methods for "prevention of air ingress" (see 5.10 and 6.10 of this Edition; 5.10 and 6.10 of the 2010 Edition); --- Change the expression of the requirements for "pH measuring device" (see 5.11 of this Edition; 5.11 of the 2010 Edition); ---Delete the requirements and test methods for "weighing scale" (see 5.12 and 6.12 of the 2010 Edition); --- Change the requirements and test methods for "network power supply interruption" (see 5.12 and 6.12 of this Edition; 5.13 and 6.13 of the 2010 Edition); --- Change the expression of requirements for "disinfection" (see 5.15 of this Edition; 5.16 of the 2010 Edition); --- Add requirements for some contents in "appearance and structure" (see 5.17 of this Edition); --- Change the requirements and test methods for "environmental test" (see 5.19 of this Edition; 5.20 of the 2010 Edition); --- Change the test method for "transmembrane pressure indication error" (see 6.7.1.1 of this Edition, 6.7.1.1 of the 2010 Edition); --- Add the test method for "arterial pressure alarm action" [see 6.7.3 b) of this Edition]; --- Change the test method for "dialysate flow, temperature, conductivity stability" (see 6.8 of this Edition; 6.8 of the 2010 Edition); --- Change the test method for "blood leakage protection system test" (see 6.9 of This Edition; 6.9 of the 2010 Edition); ---Delete "Inspection Rules" and "Marking, Instruction Manual, Packaging, Transportation and Storage" (see Clauses 7 and 8 of the 2010 Edition). Please note some contents of this Document may involve patents. The issuing agency of this Document shall not identify these patents. This Document was proposed by National Medical Products Administration. This Document shall be under the jurisdiction of National Technical Committee on Extracorporeal Circuit Equipment of Standardization Administration of China (SAC/TC 158). The historical editions replaced by this Document are as follows. --- YY 0054-1991 Hemodialysis Equipment was first-time published in 1991l --- YY 0054-2003 Hemodialysis, Hemodiafiltration and Hemofiltration Equipment; --- YY 0054-2010 Hemodialysis Equipment; --- It is the third-time revised hereby. Hemodialysis Equipment1 ScopeThis Document specifies the classification and requirements of hemodialysis equipment and describes its test methods.2 Normative ReferencesThe provisions in following documents become the essential provisions of this Document through reference in this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this Document. GB 9706.1 Medical electrical equipment - Part 1.General requirements for basic safety and essential performance3 Terms and DefinitionsFor the purposes of this Document, the terms and definitions given in GB 9706.216 and the following apply. The process that the equipment automatically controls the ratio of hemodialysis concentrate and dialysis water to prepare dialysate that meets clinical requirements.4 ClassificationThe equipment can be divided into hemodialysis type and hemodiafiltration type.5 RequirementsFor a typical 4-hour dialysis treatment, at any time during the treatment period, the difference between the actual cumulative net dehydration volume and the expected cumulative net dehydration volume shall be within ±400mL. For online equipment, the equipment's replacement fluid flow control range and control error shall comply with the manufacturer's specifications.6 Test MethodsRun hemodialysis mode and take dialysate samples after the equipment is stable. Inspect according to the test method specified in YY/T 0598; and compare it with the setting value of the dialysate composition that can be set on the equipment; the result shall meet the requirements of 5.3. Carry out the environmental test of the equipment according to the relevant provisions in GB/T 14710.The inspection terms after the environmental test shall be specified by the manufacturer, and the results shall meet the provisions of 5.19. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of YY 0054-2023 be delivered?Answer: The full copy PDF of English version of YY 0054-2023 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of YY 0054-2023_English with my colleagues?Answer: Yes. The purchased PDF of YY 0054-2023_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- YY 0054-2023 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version YY 0054-2023?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY 0054-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of YY 0054-2023?A step-by-step guide to download PDF of YY 0054-2023_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "YY 0054-2023". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |