Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJG 714-2012 PDF English

US$150.00 · In stock · Download in 9 seconds
JJG 714-2012: Verification Regulation of Blood Cell Analyzers
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

JJG 714: Historical versions

Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
JJG 714-2012150 Add to Cart Auto, 9 seconds. Verification Regulation of Blood Cell Analyzers Valid
JJG 714-1990919 Add to Cart 6 days Verification Regulation of Blood Cell Analyzer Obsolete

Similar standards

JJG 635   JJG 695   JJG 551   

JJG 714-2012: Verification Regulation of Blood Cell Analyzers

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/JJG714-2012
JJG METROLOGICAL VERIFICATION REGULATION OF THE PEOPLE’S REPUBLIC OF CHINA Replacing JJG 714-1990 Verification Regulation of Blood Cell Analyzers Issued on: JUNE 18, 2012 Implemented on: DECEMBER 18, 2012 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China 3. No action is required - Full-copy of this standard will be automatically & immediately delivered to your EMAIL address in 0~60 minutes. Verification Regulation of Blood Cell Analyzers Administrative organization. National Technical Committee of Clinical Medicine Metrology Main drafting organization. China National Institute of Metrology Participating drafting organizations. Beijing Institute of Metrology and Testing; Qingdao Institute of Metrology and Testing This Regulation shall be interpreted by the National Technical Committee of Clinical Medicine Metrology.

Table of Contents

1 Scope ... 5 2 Normative References ... 5 3 General ... 5 4 Metrological Performance Requirements ... 6 5 General Technical Requirements ... 6 6 Control of Measuring Devices ... 6 7 Handlings of Verification Results ... 9 8 Verification Cycle ... 9 Annex A Verification Original Data Log Sheet ... 10 Annex B Format of Inner-Pages of Verification Certificate/Verification Result Letter ... 13 Verification Regulation of Blood Cell Analyzers

1 Scope

This Regulation applies to the initial verification, subsequent verification and in-use verification of blood cell analyzers.

2 Normative References

The following document is referenced in this Regulation. YY/T 0653-2008, Hematology Analyzer For dated references, only the edition dated applies to this document. For undated references, the latest edition of the referenced documents (including all amendments) applies to this Regulation.

3 General

Blood cell analyzers (hereinafter referred to as analyzers) are capable of measuring the red blood cell count (RBC), white blood cell count (WBC), blood platelet count (PLT) and hemoglobin concentration (HGB) in human blood, which are mainly used for blood tests by hospitals and scientific research departments and other departments. The measuring methods for the red blood cell count in the analyzers include electrical impedance method, laser scattering method, fluorescent staining method and so on. The method widely used is the electrical impedance method; gem hole is used as the sensor; after the sensor absorbs a fixed quantity of blood cell specimen, the blood cell count is converted into the corresponding electrical pulse count. The electrical pulse is amplified, voltage discriminated and shaped; then the blood cell count is determined by measuring the electrical pulse count. The measurement of hemoglobin concentration is generally carried out in accordance with the colorimetric principle; the photoelectric element is used as the sensor; the sensor converts the variation of hemoglobin concentration into the variation of the corresponding voltage signal; the hemoglobin concentration is determined by measuring the variation of voltage after the voltage signal goes through amplification operation. The apparatus consist of mechanical system, electrical system, testing system and control system and so on. apparatus to preheat them; preset all switches and rotary knobs. The apparatus are verified in accordance with the routine procedures if their self-inspection is normal. For the apparatus having mode selection functions, set them to the whole blood measurement mode. Reagents, which are from the manufacturer or whose effectiveness can be proved, shall be used for the apparatus. 6.4.3 Blank value verification Take an appropriate amount of apparatus blank diluent to pour into a clean measuring cup; repeat the measurement for 4 times. Discard the measured value for the first time; record the maximum values of the other 3 measured results, i.e. the blank values of RBC, WBC, PLT, HGB. 6.4.4 Carryover verification Select one kind of standard substances of high and low values; mix up before use. In accordance with the sequence from high values to low values, carry out measurement continuously for 3 times. The measured values are respectively i1, i2, i3 and j1, j2, j3. Calculate the carryovers of RBC, WBC, PLT and HGB in accordance with Formula (1). where, CO—the carryover; i3—the value of standard substance of a high value measured for the third time; j1—the value of standard substance of a low value measured for the first time; j3—the value of standard substance of a low value measured for the third time. 6.4.5 Verification of indication error Take 3 ~ 5 kinds of blood cell standard substances of different concentrations within the commonly-used measuring range of the apparatus (take 5 kinds for the first verification); carry out measurement continuously for 5 times after mixing up respectively; calculate respectively the relative error ΔT of indicating value of the apparatus in accordance with Formula (2); take ΔT having the maximum absolute value as the verification results of the indication error of RBC, WBC, PLT and HGB of the apparatus. where, Ts—the standard value of standard substance;

Annex B

Format of Inner-Pages of Verification Certificate/Verification Result Letter B.1 Format of the second page of verification certificate/verification result letter Certificate No. xxxx - xxxx Verification body authorization instructions. Environmental conditions and site for verification Temperature. °C Site. Relative humidity. % Others. Metrological standard apparatus used for verification Name Measuring range Uncertainty/accuracy grade/maximum allowable error Metrological standard certificate no. Valid until Standard instruments used for verification Name Measuring range Uncertainty/accuracy grade/maximum allowable error Metrological standard certificate no. Valid until ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of JJG 714-2012 be delivered?Answer: The full copy PDF of English version of JJG 714-2012 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of JJG 714-2012_English with my colleagues?Answer: Yes. The purchased PDF of JJG 714-2012_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- JJG 714-2012 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version JJG 714-2012?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 714-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of JJG 714-2012?

A step-by-step guide to download PDF of JJG 714-2012_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "JJG 714-2012".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9