Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJG 1192-2023 PDF English

US$330.00 · In stock · Download in 9 seconds
JJG 1192-2023: Calibrator of Off-board Chargers for Electric Vehicles
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
JJG 1192-2023330 Add to Cart Auto, 9 seconds. Calibrator of Off-board Chargers for Electric Vehicles Valid

Similar standards

JJG 1194   

JJG 1192-2023: Calibrator of Off-board Chargers for Electric Vehicles

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/JJG1192-2023
JJG METEROLOGY & VERIFICATION SPECIFICATION OF THE PEOPLE’S REPUBLIC OF CHINA Calibrator of off-board chargers for electric vehicles ISSUED ON: MARCH 15, 2023 IMPLEMENTED ON: SEPTEMBER 15, 2023 Issued by: State Administration for Market Regulation

Table of Contents

Introduction ... 4 1 Scope ... 5 2 Normative references ... 5 3 Overview ... 5 4 Metering performance requirements ... 6 4.1 Electric energy error ... 6 4.2 Limit operating error ... 7 4.3 Ports and display ... 7 4.4 Repeatability of energy measurement ... 7 4.5 Indication error of monitoring unit ... 7 4.6 Clock time error ... 8 5 General technical requirements ... 8 5.1 Appearance and power inspection ... 8 5.2 AC withstanding voltage ... 8 6 Metering instrument control ... 9 6.1 Test conditions ... 9 6.2 Measuring standards and other equipment ... 9 6.3 Verification items and verification methods ... 10 6.4 Processing of verification results and test cycle ... 13 6.5 Verification cycle ... 14 Appendix A Original record format of verification ... 15 Appendix B Verification certificate/inner page format of verification result notification (page 2) ... 17 Appendix C Verification result page format of verification certificate/ verification result notification (page 3) ... 18 Verification regulation of calibrator of off-board chargers for electric vehicles

1 Scope

This Regulation applies to the first verification, subsequent verification, in-use inspection of the calibrator of off-board chargers for electric vehicles.

2 Normative references

This procedure references the following documents: JJG 1149 Off-board chargers for electric vehicles JJG 1186 Verification equipment for DC electrical energy meters JJF 1662 Calibration specification for clock testers For dated references, only the dated version applies to this regulation; for undated references, its latest version (including all amendments) applies to this Regulation.

3 Overview

The calibrator of off-board chargers for electric vehicles (hereinafter referred to as the calibrator) is a device, which is used to calibrate the electric vehicle off-board charger. It can verify the electric energy, time, current, voltage and other parameters of the off- board charger. The schematic diagram of the calibrator is as shown in Figure 1. It is mainly composed of a control unit, a charging gun port, a load interface, a DC power standard (including a monitoring unit), a clock unit, a display unit, a control guidance unit (provided by the load). The calibrator simulates the charging demand of the electric vehicle, by controlling the guiding unit. The load interface connects the simulated load, to simulate the battery of the electric vehicle, to realize the charging demand. The monitoring unit measures parameters such as voltage and current; completes the metering and error test of the electric energy by the DC electric energy standard. The measured quantity is output to the display unit. 4.6 Clock time error The absolute error of the clock time is better than ±1 s.

5 General technical requirements

5.1 Appearance and power inspection The calibrator shall display the following information: - Product name and model; - Manufacturer and exit-factory number; - Pulse constant C (imp/kWh); - Level of accuracy; - Measuring range. After the calibrator is powered on, the functions and software control shall be normal. 5.2 AC withstanding voltage The calibrator powered by AC is in the non-working state; the power switch is placed in the ON position; the voltage of AC 1.5 kV is applied between the input terminal of the power supply and the casing, for a duration of 1 min. There shall be no spark discharge or breakdown. All the lines, whose reference voltage exceeds 40 V, are connected together as one point; the other point is the grounded. The test voltage is applied between these two points, which shall be able to withstand the AC 3 kV withstanding voltage test for 1 minute. There shall be no spark discharge or breakdown during the test. time is not less than 5 s. 2) Watt-second method Use the measurement standard to measure the set constant power. Use the standard timer to measure the time, which is required for the calibrator to accumulate the electric energy value. This time is multiplied by the constant power to obtain the measure electric energy, which is then compared with the accumulative electric energy of the calibrator, to determine the relative error of the calibrator's electric energy. When the calibrator is verified by the watt-second method, the time measurement error (%) of the standard time measuring device shall not be greater than 1/20 of the accuracy level of the calibrator. When counting and reading the time, the standard time meter shall have enough readings, so that the reading error of 1 word due to the change of the last digit does not exceed 1/10 of the accuracy level of the calibrator. c) Cumulative power error At 500 V and Imax, the calibrator runs synchronously with the current line of the measurement standard in series and the voltage line in parallel. The cumulative electric energy value shall meet the requirements of 4.1. Calculate the relative error γ', according to formula (3). 6.3.2.4 Limit operating error Carry out verification, according to the test load point, which is specified in Table 10. The verification is according to 6.3.2.3. 6.3.2.5 Energy measurement repeatability Under repeatability conditions, conduct no less than 5 electric energy error determinations, according to the provisions in Table 3. Calculate the standard deviation ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of JJG 1192-2023 be delivered?Answer: The full copy PDF of English version of JJG 1192-2023 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of JJG 1192-2023_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1192-2023_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- JJG 1192-2023 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of JJG 1192-2023?

A step-by-step guide to download PDF of JJG 1192-2023_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "JJG 1192-2023".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9