Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JC/T 1043-2007 PDF English

US$110.00 · In stock · Download in 9 seconds
JC/T 1043-2007: Limit of lead extraction in faucets
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
JC/T 1043-2007110 Add to Cart Auto, 9 seconds. Limit of lead extraction in faucets Valid

Similar standards

JG/T 311   HJ/T 296   JC/T 2759   

JC/T 1043-2007: Limit of lead extraction in faucets

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/JCT1043-2007
ICS 91.140.701 Q31 Reference No.. 20879 -2007 JC Industry Standard of the People's Republic of China Replacing 7155-1993 Limit of lead extraction in faucets Issued on: MAY 29, 2007 Implemented on: NOVEMBER 11, 2007 Issued by. National Development and Reform Commission of the People’s Republic of China

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Terms and definitions ... 4 4 Requirements ... 5 5 Test Methods ... 5

Foreword

This Standard references to chapter 9 The Parts Of Mechanical Piping Equipment of NSF/ANSI 61-2003e “Drinking water system components - Health effects”, the technical requirements and test methods of lead test statistical Q value is same as this Standard. This Standard is under the Jurisdiction of National Technical Committee on Architecture and Sanitary Ceramics of Standardization Administration of China. This Standard is responsibly drafted by organizations. National Building Material Industry Hardware and Plumbing Equipment Quality Supervision Test Center, China Building Ceramics & Sanitary Ware Association, and Sanitary Wares Accessories Branch of China Building Ceramics & Sanitary Ware Association. Participating organizations in the draft of this Standard. Guangdong Chaoyang sanitary Co., Ltd, Joyou Group Co., Ltd, Sunlot Group Co., Ltd, and Fujian Huihuang Sanitary and Plumbing Group Co., Ltd. This Standard is mainly drafted by. Shi Hongwei, Xiao Ruifeng, Wang Wei and Miao Bin. Limit of lead extraction in faucets

1 Scope

This Standard specifies technical requirements and test methods of lead extraction in faucets. This Standard applies to brass faucets for drinking water installed at the end of water supply pipeline.

2 Normative references

The following normative documents contain provisions which, through reference in the text, constitute provisions of this Standard. For dated reference, subsequent amendments or revisions (excluding contents of corrigenda) do not apply. However, parties who enter into agreement based on this Standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. For undated references, the latest edition of the normative document referred to applies. GB 5750-1985 Standard examination methods for drinking water NSF/ANSI 61-2003e System Components Drinking Water - Health Effects

3 Terms and definitions

The following terms and definitions apply to this Standard. 3.1 Cold water volume Under normal operating conditions, the device connects the supply of hot and cold water, the cold water volume is the volume (from inlet to outlet) contained in the part of device usually contacting cold water. This part of volume usually excludes the water volume of the part of device which only contacts with hot water. 3.2 Cold mix volume adjustment factor (CMV) The cold water volume of device divided by the entire water volume of device. V - The volume of chlorine stock solution needed to be added, mL; B - The volume of extraction water, L; A - The concentration of chlorine stock solution, mg / mL. 5.2.1.3 0.4 mol/L Sodium bicarbonate solution DISSOLVE 33.6 g of anhydrous sodium bicarbonate into reagent water, and DILUTE it with reagent water to 1L, MIX well, PREPARE fresh solution every week. 5.2.2 Preparation of extraction water TAKE 25 mL of 0.4 mol / L sodium bicarbonate solution (5.2.1.3), the right amount of chlorine stock solution (5.2 1. 2), USE reagent water to DILUTE it to 1 L, USE 0.1 mol / L hydrochloric acid to adjust the pH value. The solution shall meet the following requirements. pH. 8 0 ± 0 5, alkalinity. (500 ± 25) mg / L, inorganic carbon. (122 ± 5) mg / L, chlorine. 2 mg / L. 5.3 Washing RINSE the sample with water for 15 min, and then WASH it three times with reagent water, WASH away residue and dirt within the sample. 5.4 Sample Adjustment At room temperature of (23 ± 2) °C, WASH it with extraction water three times. Extraction water shall completely fill the sample until the beginning of the extraction, and the process shall not exceed 72 h. 5.5 Extraction Extraction shall be conducted at room temperature of (23 ± 2) °C. After conducting sample adjustment, FILL the sample with extraction water; ENSURE extraction area is maximum. PLUG tightly both ends of the sample with clean cork coated with a PTFE film or rubber stopper. EXTRACT it in accordance with extraction order in Table 1. For example. On the 1st day 8. 00 am FILL extraction water; REPLACE after 2 h; REPLACE continuously for four times; and COMPLETE the replacement of water extraction at 16. 00 pm of that day; KEEP for 16 h; on the 2nd day, REPEAT the same course of the 1st day. REPEAT the same course as the 1st day on the 3rd day, the 4th day, and the 5th day; and COLLECT the extraction water ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of JC/T 1043-2007 be delivered?Answer: The full copy PDF of English version of JC/T 1043-2007 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of JC/T 1043-2007_English with my colleagues?Answer: Yes. The purchased PDF of JC/T 1043-2007_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- JC/T 1043-2007 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of JC/T 1043-2007?

A step-by-step guide to download PDF of JC/T 1043-2007_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "JC/T 1043-2007".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9