GB/T 8627-2007 PDF EnglishUS$85.00 · In stock · Download in 9 seconds
GB/T 8627-2007: Test method for density of smoke from the burning or decomposition of building materials Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB/T 8627: Historical versions
Similar standardsGB/T 8627-2007: Test method for density of smoke from the burning or decomposition of building materials---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT8627-2007 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 13.220.50 Q 10 Replacing GB/T 8627-1999 Test Method for Density of Smoke from the Burning or Decomposition of Building Materials Issued on: DECEMBER 21, 2007 Implemented on: JUNE 1, 2008 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of the People's Republic of China. Table of ContentsForeword ... 3 1 Application Scope ... 4 2 Normative References ... 4 3 Test Method ... 4 4 Test Apparatus ... 5 5 Test Specimen ... 7 6 Conditioning ... 7 7 Test Procedure ... 8 8 Special Procedure ... 9 9 Optional Procedure ... 9 10 Treatment of Data ... 9 11 Test Report ... 10 Appendix A (Informative) Cross Reference of the Article Numbers of this Standard and the Article Numbers of ASTM D2843-1999 ... 17 Appendix B (Informative) Technical Differences between This Standard and ASTM D2843-1999 and Their Reasons ... 19ForewordThis Standard modifies and adopts ASTM D2843-1999, Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics (English edition). This Standard was redrafted in accordance with ASTM D2843-1999. The cross reference of the article numbers of this Standard and the article numbers of ASTM D2843-1999 is listed in Appendix A. In consideration of the national conditions of China, some modifications are made in this Standard when it adopts ASTM D2843-1999; the list of these technical differences and their reasons are given in Appendix B. This Standard replaces GB/T 8627-1999, Test Method for Density of Smoke from the Burning or Decomposition of Building Materials. Compared with GB/T 8627-1999, the main technical changes of this Standard are as follows. -- it specifies the steel wire mesh opening size in specimen holder is 6 mm while GB/T 8627-1999 only specifies the side length is 5 mm (see 2.1.5 of edition 1999); -- it deletes the note “During a non-arbitration test, liquified petroleum gas can be used as the fuel gas for test” (2.2.1 of edition 1999); -- it specifies the working pressure of propane is changed from 210 kPa to 276 kPa (see 4.3.1 of this edition); and -- it adds special procedure for materials that drip and adds auxiliary burner and collector tray and so on. Meanwhile, it adds optional procedure (see Article 8 and Article 9). Appendix A and Appendix B of this Standard are informative. This Standard was proposed by the Ministry of Public Security of the People’s Republic of China. This Standard shall be under the jurisdiction of Subcommittee 7 of the National Technical Committee on Fire Protection (SAC/TC 113/SC 7). The responsible drafting organization of this Standard. Sichuan Fire Research Institute of Ministry of Public Security. The main drafters of this Standard. Zhao Chenggang, Liu Songlin, Zeng Xubin, Yao Jianjun and Yu Yingfei. The editions of the standard replaced by this Standard are as follows. -- GB/T 8627-1988 and GB/T 8627-1999. Test Method for Density of Smoke from the Burning or Decomposition of Building Materials1 Application ScopeThis Standard specifies the specific requirements for the test apparatus, test procedure, calculation of test results and test report for density of smoke from the density or decomposition of building materials. This Standard specifies the test method for the measurement of volume of smoke produced under controlled conditions of combustion or decomposition. The measurements with this test method are made in terms of the loss of light transmission through a collected volume of smoke produced under controlled, standardized conditions. The apparatus is constructed so that the flame and smoke is observable during the test. This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.2 Normative ReferencesThe provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB/T 2918-1998, Plastics – Standard Atmospheres for Conditioning and Testing ( idt. ISO 291.1997)3 Test Method3.1 It is intended to determine the possible smoke release of building materials under controlled conditions of combustion and decomposition. The principle is to evaluate the smoke density by measuring the loss of light transmission through a solid dust of smoke produced under conditions of combustion and decomposition of materials. 3.2 The test specimen is exposed to flame for the duration of the test, and the smoke shall focus a spot of light on the photocell in the right instrument panel. 4.4.3 Another box containing the photometer shall be attached to the right side of the chamber. The barrier-layer photoelectric cell shall have standard observer spectral response. An egg-crate grid in front of the photocell shall be used to protect the cell from stray light. The grid shall be finished in dull black and have openings at least twice as deep as they are wide. The current produced by the photocell is indicated in terms of percent light absorption on a meter. The photocell linearity decreases as the temperature increases; compensations shall therefore be made. The photocell shall not be operated at temperatures exceeding 50°C. 4.4.4 The meter shall have two ranges. The range change shall be accomplished by shunting the meter to one tenth of its sensitivity. When smoke accumulates to absorb 90 percent of the light beam, the meter shall be set to its basic sensitivity, by any appropriate manner. By doing this, the scale in the meter will then read from 90 to 100 % absorption instead of reading from 0 to 100 % absorption. 4.5 Timing Device A timing device shall be used to indicate 15-s intervals. The timing device shall start measuring when the burner is swung into test position. 4.6 Planimeter A planimeter or other suitable means shall be used for measuring the area under the light-absorption curve.5 Test Specimen5.1 The standard specimen shall be 25.4 ± 0.3 by 25.4 ± 0.3 by 6.2 ± 0.3 mm. Other thicknesses can also be used; however, their thickness shall be stated in the report together with smoke density. Material thinner than 6.2 mm shall be tested by stacking and forming a composite specimen 6.2 mm thick. Material thicker than 6.2 mm shall be tested by machining the material down to a thickness of 6.2 mm. The maximum thickness of specimen is 25mm; when the thickness of material is greater than 25 mm, decide the fire exposure face in accordance with actual application conditions and reserve the fire exposure face during cutting. 5.2 The test sample shall consist of three specimens. The specimens shall be sanded, machined, or die cut in a manner that produces a cut surface that is free from projecting fibers, chips, and ridges.6 Conditioning6.1 Conditioning – Condition the test specimens for not less than 40 h prior to test in accordance with the ambient conditions specified in GB/T 2918-1998. During calibration, the mean value the three differences between the indicating value of light quantity and the calibrated value of standard filters shall be less than 3% (absolute value).8 Special Procedure8.1 For materials that drip, a second or auxiliary burner (with separate propane gas supply) shall be introduced into the chamber. See Figure 5 and auxiliary burner parts list. 8.2 Use a stainless steel collector tray to replace calcium-silicate sheet (1B in Figure 1) collector tray. The collector tray is tapered and collects drippings at the bottom (see 11 in Figure 5). 8.3 The auxiliary burner shall be ignited at the same time the standard burner is ignited. The auxiliary burner shall be operated at 138 kPa and it shall be positioned in such a manner that its flame is directed at the center of the collector tray.9 Optional Procedure9.1 Data acquisition hardware or a potentiometric recorder can be employed to record the output of the photocell versus time. 9.2 With a suitably sensitive meter, more than one decade chan... ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 8627-2007 be delivered?Answer: The full copy PDF of English version of GB/T 8627-2007 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 8627-2007_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 8627-2007_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 8627-2007 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version GB/T 8627-2007?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 8627-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of GB/T 8627-2007?A step-by-step guide to download PDF of GB/T 8627-2007_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 8627-2007". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |