GB/T 43721-2024 PDF EnglishUS$245.00 · In stock · Download in 9 seconds
GB/T 43721-2024: Textiles - Determination of benzalkonium chloride Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
Similar standardsGB/T 43721-2024: Textiles - Determination of benzalkonium chloride---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT43721-2024GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 59.080.01 CCS W 04 GB/T 43721-2024 Textiles - Determination of benzalkonium chloride Issued on: MARCH 15, 2024 Implemented on: OCTOBER 01, 2024 Issued by. State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of ContentsForeword... 3 1 Scope... 4 2 Normative references... 4 3 Terms and definitions... 4 4 Principle... 4 5 Reagents and materials... 4 6 Instruments... 5 7 Test steps... 6 8 Calculation and expression of results... 8 9 Detection limit, limit of quantification and precision... 9 10 Test report... 9 Annex A (normative) Chemical information of benzalkonium chloride... 11 Annex B (informative) HPLC-DAD analysis conditions... 12 Annex C (informative) High performance liquid chromatogram and spectrum of benzalkonium chloride... 13 Annex D (informative) HPLC-MS/MS analysis conditions... 16 Annex E (informative) Multiple reaction monitoring selected ion flow chromatogram of benzalkonium chloride... 18 Textiles - Determination of benzalkonium chloride WARNING -- Persons using this document shall be familiar with normal laboratory practice. This document does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices and to ensure compliance with any national regulatory conditions.1 ScopeThis document describes the test methods for the determination of benzalkonium chloride in textiles using high performance liquid chromatography-diode array detector (HPLC-DAD) or high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). This document applies to all types of textile products.2 Normative referencesThe following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682 Water for analytical laboratory use - Specification and test methods3 Terms and definitionsFor the purpose of this document, there are no terms and definitions that need to be defined.4 PrincipleUse acetonitrile to ultrasonically extract the benzalkonium chloride in the sample, after the extract is filtered through a filter membrane, it is determined by HPLC-DAD or HPLC-MS/MS and quantified by the external standard method.5 Reagents and materialsUnless otherwise specified, all reagents are at least analytical grade. 5.1 Water. grade 2 water as specified in GB/T 6682. 5.2 Acetonitrile. CAS No. 75-05-8, chromatographic grade. 5.3 Methanol. CAS No. 67-56-1, chromatographic grade. 5.4 Formic acid. CAS No. 64-18-6. 5.5 Ammonium acetate. CAS No. 631-61-8. 5.6 Glacial acetic acid. CAS No. 64-19-7. 5.7 Three kinds of benzalkonium chloride standard substances. comply with the provisions of Annex A, purity ≥ 97.0 %. 5.8 Mixed standard stock solution. Use an analytical balance (6.3) to weigh a certain amount of each benzalkonium chloride standard substance (5.7), dissolve and make up to the mark with acetonitrile (5.2), to prepare a mixed standard stock solution with a mass concentration of 1000 mg/L. NOTE. The mixed standard stock solution is stored in a refrigerator at 0 ℃ ~ 8 ℃ and has a shelf life of 6 months. 5.9 Mixed standard working solution. Accurately pipette a certain volume of the mixed standard stock solution (5.8) and dilute with acetonitrile (5.2) to obtain series mixed standard working solutions of at least 5 different concentrations. When using HPLC- DAD for analysis, prepare mixed standard working solutions of a series of concentrations, such as 5.0 mg/L, 10.0 mg/L, 20.0 mg/L, 50.0 mg/L, and 100.0 mg/L; when using HPLC-MS/MS for analysis, prepare mixed standard working solutions of a series of concentrations, such as 0.05 mg/L, 0.10 mg/L, 0.20 mg/L, 0.50 mg/L, and 1.00 mg/L. This solution is prepared and used immediately. 5.10 Ammonium acetate solution. Weigh 7.70 g of ammonium acetate (5.5) and place in a beaker, add water (5.1) to dissolve and dilute to 1000 mL, adjust the pH to 5.0 with glacial acetic acid (5.6), and filter with an aqueous filter membrane (5.13). 5.11 0.1 % formic acid solution. Pipette 1 mL of formic acid (5.4) into a 1000 mL volumetric flask and make up to the mark with water (5.1). 5.12 Organic phase filter membrane. pore size 0.22 μm, made of polytetrafluoroethylene (PTFE). 5.13 Aqueous phase filter membrane. pore size 0.22 μm, made of mixed cellulose ester (MCE).6 Instruments6.1 High performance liquid chromatograph (HPLC). equipped with a diode array detector (DAD). 6.2 High performance liquid chromatography-tandem mass spectrometer (HPLC- MS/MS). equipped with an electrospray ionization source (ESI). 6.3 Analytical balance. the graduation values are 0.01 g and 0.0001 g. 6.4 Ultrasonic water bath generator. the working frequency is (40 ± 5) kHz, the water bath temperature can be controlled at (60 ± 3) ℃. 6.5 pH meter. the graduation value is 0.01. 6.6 Glass container. 40 mL ~ 60 mL, made of hard glass, with a screw-on sealing cover. 6.7 Volumetric flask. 1000 mL.7 Test steps7.1 Sample preparation Take a representative sample, cut it into pieces less than 5 mm × 5 mm, and mix it thoroughly. 7.2 Sample extraction Weigh (1 ± 0.1) g of sample, accurate to 0.01 g, place in a glass container (6.6), add 20 mL of acetonitrile (5.2), tighten the sealing cover, place in a (60 ± 3) ℃ ultrasonic water bath generator (6.4) for ultrasonic extraction for (30 ± 1) min, take out the glass container (6.6) and cool to room temperature, take part of the extract and filter through the organic phase filter membrane (5.12), and the filtrate is used as the test liquid for analysis on the instrument. 7.3 HPLC-DAD analysis Under the same test conditions, take equal volumes of the test solution obtained in 7.2 and the mixed standard working solution (5.9) and alternately inject them for determination. The HPLC-DAD analysis conditions are shown in Annex B. Qualitative analysis is performed by comparing the retention time of the chromatographic peak at a specific detection wavelength and the ultraviolet absorption spectrum. If the relative deviation between the retention time of the target analyte in the test solution and the retention time corresponding to the standard substance is within the range of ±2.5 %, the ultraviolet absorption spectrum is consistent with that of the standard substance, and the maximum absorption wavelength deviation is within the range of ±2 nm, it can be determined that the corresponding target analyte exists in the sample. Under the HPLC-DAD analysis conditions given in Annex B, the chromatogram and spectrum of benzalkonium chloride obtained are shown in Annex C. According to the content of the target analyte in the test solution, select a mixed standard working solution (5.9) with a similar response value for analysis. With the response peak area of the target analyte as the vertical axis and the concentration of the target analyte as the horizontal axis, plot a standard working curve, and perform quantitative analysis according to the external standard method. The response values of the target analyte in the mixed standard working solution (5.9) and the test solution obtained in 7.2 shall be within the linear response range of the instrument. If the content exceeds the range of the standard curve, dilute with acetonitrile to an appropriate concentration before determination. 7.4 HPLC-MS/MS analysis Under the same test conditions, take equal volumes of the test solution obtained in 7.2 and the mixed standard working solution (5.9) and alternately inject them for determination. The HPLC-MS/MS analysis conditions are shown in Annex D. Compare the retention times of the mass chromatographic peaks of the test solution and the mixed standard working solution (5.9). If the relative deviation between the retention time of the target analyte in the test solution and the retention time corresponding to the standard substance is within the range of ±2.5 %, and the deviation between the relative ion abundance of the qualitative ion pair and the relative ion abundance of the standard working solution with equivalent concentration do not exceed the range specified in Table 1, it can be determined that the corresponding target analyte exists in the sample. Under the HPLC-MS/MS analysis conditions given in Annex D, the multiple reaction monitoring selected ion current chromatogram of each benzalkonium chloride is shown in Annex E. According to the content of the target analyte in the test solution, select a mixed standard working solution (5.9) with a similar response value for analysis. Use the response peak area of the target analyte as the vertical axis and the concentration of the target analyte as the horizontal axis, plot a standard working curve, and perform quantitative calculation according to the external standard method. The response values of the target analyte in the mixed standard working solution (5.9) and the test solution obtained in 7.2 shall be within the linear response range of the instrument. If the content exceeds the range of the standard curve, dilute with acetonitrile to an appropriate concentration before determination. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 43721-2024 be delivered?Answer: The full copy PDF of English version of GB/T 43721-2024 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 43721-2024_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 43721-2024_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 43721-2024 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of GB/T 43721-2024?A step-by-step guide to download PDF of GB/T 43721-2024_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 43721-2024". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |