GB/T 39951-2021 PDF EnglishUS$195.00 · In stock · Download in 9 seconds
GB/T 39951-2021: Evaluation method for degradability of disposable paper products Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
Similar standardsGB/T 39951-2021: Evaluation method for degradability of disposable paper products---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT39951-2021GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 85.010 Y 30 Evaluation method for degradability of disposable paper products ISSUED ON: MARCH 09, 2021 IMPLEMENTED ON: OCTOBER 01, 2021 Issued by: State Administration for Market Regulation; Standardization Administration of the People's Republic of China. Table of ContentsForeword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Terms and definitions ... 4 4 Principle ... 5 5 Tests... 6 6 Evaluation rules ... 17 7 Test report ... 17 Annex A (informative) Example of biodegradability test system ... 19 Annex B (normative) Ecotoxicity test ... 20 Evaluation method for degradability of disposable paper products WARNING - Personnel using this Standard shall have practical experience working in a formal chemical laboratory. This Standard does not point out all possible safety issues. The user is responsible for taking appropriate safety and health measures and ensuring compliance with the conditions stipulated by relevant national laws and regulations.1 ScopeThis Standard specifies evaluation methods for biodegradability, degree of disintegration and ecotoxicity of disposable paper products under aerobic composting conditions. This Standard is applicable to evaluation for degradability of disposable paper products and raw materials such as diapers (sheets, pads), sanitary napkins (pads), wet wipes, paper cups, paper tableware, paper bags, paper boxes, pulp molded products. It is also applicable to paper-based composite materials and products.2 Normative referencesThe following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682, Water for analytical laboratory use - Specification and test methods GB/T 30903, Inorganic chemicals for industrial use - Determination of impurity element - Inductively coupled plasma mass spectrometry (ICP-MS)3 Terms and definitionsFor the purposes of this document, the following terms and definitions apply. 3.1 compost passing through the 2mm test sieve to the total dry solids. During ecotoxicity test, the compost obtained after the disintegration of the specimen is mixed with the reference culture soil in a precise ratio. Place in the tray. Evaluate the ecotoxicity of the specimen by inspecting the number of germination of seeds.5 Tests5.1 Biodegradability test 5.1.1 Reagents and materials Unless otherwise specified, the reagents used in this Standard refer to analytically-pure reagents. Microbiology reagents shall meet the requirements of microbiology. 5.1.1.1 Water: GB/T6682, grade three. 5.1.1.2 Trace element solution: the solute concentrations are: boric acid: 500mg/L, potassium iodide: 100mg/L, ferric chloride: 200mg/L, manganese sulfate: 400mg/L, ammonium heptamolybdate: 200mg/L, ferrous sulfate: 400mg/L. 5.1.1.3 Mineral solution: Measure 1mL of calcium chloride solution with a concentration of 0.1g/L, 1mL of sodium chloride solution with a concentration of 0.1g/L, 1mL of trace element solution (5.1.1.2). Weigh 1.0g of potassium dihydrogen phosphate and 0.5g of magnesium sulfate. Use water to set volume to 1000mL. 5.1.1.4 Compost extract: Use the compost produced in the composting device such as organic matter in municipal solid waste, garden and farmland waste to add into water. The mass volume ratio is 1:5. Place for 30min. Use a filter screen with a pore size of about 1mm or a medium-speed qualitative filter paper to filter and remove the residue. Or use a centrifuge to centrifuge at 1000r/min for 15min. Or directly use commercial special inoculants for composting. Prepare according to instructions for use. 5.1.1.5 Inoculum: Measure 500mL of mineral solution (5.1.1.3) and 500mL of compost extract (5.1.1.4). Mix well. Add 10.0g of peptone, 3.0g of beef dipping powder, 5.8g of urea, 20.0g of corn starch, 20.0g of cellulose powder. 5.1.1.6 Reference material: Use thin layer chromatography (TLC) microcrystalline cellulose as a positive control reference material. The particle size is less than 20μm. 5.1.2.10 High-speed pulverizer: Speed is ≥8000r/min. 5.1.2.11 pH meter: The reading is to the nearest of 0.1 or higher. 5.1.3 Specimen processing Do not touch the specimen with hands. Wear clean powder-free protective gloves when processing specimens. Cut the specimen into small pieces of about 10mm×10mm with scissors. Mix well. Use the high-speed crusher (5.1.2.10) to crush the fragments into flocs. Avoid specimen loss during crushing. Prepare three specimens. The weight of each specimen is within 30g~70g. Try to ensure that each specimen contains an integer number (pieces) of all the components of the specimen. If the mass of a single (piece) specimen is greater than 70g, then take 30g~70g of specimen. Ensure that the specimens taken are representative. NOTE: Specimens also include powder, granular or other simple shapes. 5.1.4 Test steps 5.1.4.1 Method A: Aerobic composting method 5.1.4.1.1 Determination of total organic carbon content 5.1.4.1.1.1 Total organic carbon content of specimen According to the instructions for use of the total organic carbon analyzer (5.1.2.9), preheat and calibrate. Prepare another specimen according to 5.1.3. Use a balance to take 50mg~100mg (depending on the test range and accuracy of the instrument), to the nearest of 0.1mg. Put it into the high temperature resistant specimen cup for testing. Test for 10 times in total. Take the average of 10 test results as the total organic carbon content of the specimen. The result is rounded to 0.0001g/g. 5.1.4.1.1.2 Total organic carbon content of reference material Refer to 5.1.4.1.1.1 to test the total organic carbon content of the reference material (5.1.1.6). Test twice in total. Take the average value as the total organic carbon content of the reference material. The result is rounded to 0.0001g/g. 5.1.4.1.2 Test preparation stage 5.1.4.1.2.1 Preparation of activated vermiculite Mix the vermiculite (5.1.1.7) with the inoculum (5.1.1.5) at a ratio of 1:3 (mass : volume). Place it in the vermiculite activation reactor (5.1.2.7). Incubate at (50±2)°C for 3d~4d. If necessary, use water to make up to the initial mass by required moisture content by adding water or draining water, passing in wet air or dry air. If adjustments are made, the amount of carbon dioxide emitted shall be closely monitored. Compost cultivation until the specimen reaches the maximum level of biodegradation. The composting cycle generally does not exceed 6 months. If obvious biological decomposition can be observed, then the test period shall be extended to the constant plateau stage. If the plateau stage occurs earlier, that is, when the level of biodegradation no longer increases, then it can shorten the test cycle and stop the test. NOTE: If the pH is lower than 7.0, it is because the easily decomposed sample quickly decomposes to acidify the compost, which will inhibit the biological decomposition of the material. To prevent acidification, it can increase the amount of compost in all compost containers. Or decrease the specimen, increase the compost, and repeat the test. 5.1.4.1.4 Carbon dioxide emission test During the test, regularly use the carbon dioxide analysis equipment (5.1.2.6) to measure the carbon dioxide content in the exhaust gas of each compost container. Calculate the cumulative amount of carbon dioxide released. The number of measurements depends on the method used, the accuracy of the required biodegradation curve, and the biodegradability of the specimen. If the measurement method of carbon dioxide analysis instrument is used, measure at least 2 times a day in the biodegradation stage. In the steady phase, measure at least once a day. The gas flow rate at the outlet shall be accurately measured. If the measurement method of sodium hydroxide absorption and release of carbon dioxide is used, then measure dissolved inorganic carbon once a day in the biological decomposition stage; in the stationary phase, measure 2 times a week. 5.1.4.2 Method B: Component analysis method For multi-component products, the level of biodegradation of the product shall be calculated based on the level of biodegradation of each component (material). For components with unknown level of biodegradation, then use method A (5.1.4.1) to determine the level of biodegradation of each component. Calculate the level of biodegradation of the sample according to 5.1.5.2, of which the mass of each component is accurate to 0.001g. 5.1.5 Calculation and presentation of results 5.1.5.1 Calculation of level of biodegradation of aerobic composting 5.1.5.1.1 Level of biodegradation of specimen Calculate the level of biodegradation of specimen according to formula (1): 5.2 Disintegration degree test 5.2.1 Instruments and equipment 5.2.1.1 Compost container The volume of the compost container shall be large enough (the smallest volume is 140L), so as to ensure that natural heating can occur. The material shall be made of strong, high-temperature resistant, and non-biodegradable materials. Does not affect the composting process or the quality of compost when used. The bottom layer of the compost container has at least a 5cm thick drip plate to form a drainage system. Use suitable air supply system to provide adequate and continuous ventilation conditions for each compost container. 5.2.1.2 Temperature measuring equipment The reading is to the nearest of 0.1°C. 5.2.1.3 pH meter The reading is to the nearest of 0.1 or higher. 5.2.1.4 Oxygen test equipment The reading is to the nearest of 0.1%. 5.2.1.5 Sieve Use a test sieve with a suitable shape and 2mm mesh. 5.2.2 Test steps 5.2.2.1 Test preparation stage 5.2.2.1.1 Preparation of biomass waste Use the used biomass waste as carrier substrate. Try to take samples from the inputs of composting equipment that mainly treats municipal waste. The sample can also be directly sourced from biomass waste from households or grocery stores. NOTE: The typical artificial biomass waste containing the following ingredients can be selected: - Fresh fruit and vegetable mixed waste; - Rabbit feed (seeds and extruded dried vegetable pellets); four weeks, conduct once a week. Conduct once every two weeks after that until the test ends. If a specimen grid is used, open the grid and turn the ingredients inside. 5.2.2.2.2 Ventilation Regularly measure the oxygen content of composted materials or the air consumed. Measure at least once every working day during the first month of the test. Conduct once a week thereafter. The oxygen content in the composted material shall be higher than 10%. If the oxygen content is less than 10%, ventilate the biomass waste. The air flow rate per kilogram of total dry solids shall be less than 15L/h. NOTE: Air flow can control the temperature and moisture content of the compost container. The air flow to ventilate the compost container shall be consistent with the actual composting equipment. If an excessively high air flow rate is used in practical applications, the amount of ammonia lost with the air can be supplemented by adding some substances (such as urea). 5.2.2.2.3 Moisture content and pH After turning, take specimens from each test series to measure moisture content and pH. If the moisture content (mass fraction less than 40%) is too low, it will not be conducive to the normal progress of the composting process. Water shall be added at this time. 5.2.2.2.4 Temperature Measure the temperature in the middle of the compost, at least once every working day. 5.2.2.3 Termination of test 5.2.2.3.1 Cycle The cultivation cycle is 3 months. 5.2.2.3.2 Residual material Use a 2mm mesh sieve to sieve all materials. Use running water to wash carefully as much as possible. The washed pellets are dried to constant weight at 105°C (materials with a melting point lower than 105°C is at 40°C). Determine the total dry solids of fragments larger than 2mm. 5.2.3 Calculation Weigh the mass of the specimen collected in fragments larger than 2mm. Compare with the mass of the starting specimen (5.2.2.1.2). Calculate the 5.4.2 Test methods When fluorine content is measured, the specimen is calcined in a high- temperature furnace at 1000°C for 15min under the condition of water vapor and oxygen. Collect condensate. Then use ion chromatograph to test. Other elements are tested according to GB/T 30903.6 Evaluation rules6.1 If the product needs to provide proof of biodegradability (degradation) performance, a biodegradability test shall be carried out. 6.2 If the product needs to provide a certificate of compostability, it shall carry out biodegradability test, disintegration test and ecotoxicity test. The content of heavy metals, toxic and harmful substances in the product shall meet the requirements of Table 1.7 Test reportThe test report shall contain the followings: a) Reference to this Standard; b) Source of vermiculite and compost extract in the biodegradability test; c) Total organic carbon content of the reference material in the biodegradability test and its biodegradation rate in 45d; d) Total organic carbon content of the specimen in the biodegradability test and its maximum level of biodegradation; e) Source of the biomass waste in the disintegration test and the results of all the analyses performed at the beginning of the test; f) Degree of disintegration of the specimen in the disintegration test; g) Source of reference culture soil in the ecotoxicity test; h) Germination rate of blank compost in the ecotoxicity test; i) Ratio of germination number between compost specimen and blank compost in the ecotoxicity test; j) Content of heavy metals, toxic and harmful substances;Annex B(normative) Ecotoxicity test B.1 Simulation of reference culture soil Any soil that can make seeds germinate and plants grow normally can be used as a reference cultivation soil. No additional fertilizer shall be added to the reference culture soil. B.2 Sample preparation Use 50% (mass fraction or volume fraction, stated in the report) compost and reference culture soil to prepare a mixture (sample). The "compost sample" is a mixture of the final product obtained after the disintegration of the specimen and the reference culture soil. The "blank compost" is the reference culture soil without adding the specimen after disintegration. B.3 Plant species Use mung bean and wheat in plant species to conduct eco-toxicity test separately. B.4 Test steps Take at least 12 trays to test mung bean and wheat separately. Each plant requires 3 to hold compost samples and 3 to hold blank compost. Each tray is filled with at least 200g of sample (B.2). Add at least 100 seeds (B.3) on the upper surface. Use thin layer of inert material to cover seeds, such as silicate sand or perlite. Conduct three sets of parallel tests for each sample. Add water to 70%~100% of the water retention capacity. Regularly replenish the water lost due to evaporation throughout the test period. NOTE: Tray size is about 30cm×20cm×5cm (length × width × height). During germination, place the tray in a dark place or cover it. B.5 Result evaluation Check the number of sprouts of compost samples and blank compost. Use the number value of plant germination to calculate the ratio of the number of sprouts between the compost sample and the blank compost, expressed in percentage. B.6 Validity of results ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 39951-2021 be delivered?Answer: The full copy PDF of English version of GB/T 39951-2021 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 39951-2021_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 39951-2021_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 39951-2021 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of GB/T 39951-2021?A step-by-step guide to download PDF of GB/T 39951-2021_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 39951-2021". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |