GB/T 38413-2019 PDF EnglishUS$150.00 · In stock · Download in 9 seconds
GB/T 38413-2019: Textiles - Test methods for filtration of particulate matter Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
Similar standardsGB/T 38413-2019: Textiles - Test methods for filtration of particulate matter---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT38413-2019GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 56.080.30 W 04 Textiles - Test methods for filtration of particulate matter ISSUED ON: DECEMBER 31, 2019 IMPLEMENTED ON: JULY 01, 2020 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of ContentsForeword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Terms and definitions ... 4 4 Principle ... 5 5 Test equipment ... 5 6 Materials and reagents ... 8 7 Sample ... 8 8 Test conditions ... 10 9 Test procedure ... 10 10 Test data processing ... 13 11 Test report ... 14 References ... 15 Textiles - Test methods for filtration of particulate matter1 ScopeThis Standard specifies the test method for determining the filtration of particulate matter of textiles. This Standard applies to products such as fabrics for air filtration and masks.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document. GB/T 6529, Textiles - Standard atmospheres for conditioning and testing GB/T 6682, Water for analytical laboratory use - Specification and test methods GB/T 8629-2017, Textiles - Domestic washing and drying procedures for textile testing GB/T 10586, Specification for damp heat testing chambers GB/T 10589, Specifications for low temperature test chambers GB/T 11158, Specifications for high temperature test chambers3 Terms and definitionsThe following terms and definitions are applicable to this document. 3.1 Particulate matter PM2.5 Particulate matter whose aerodynamic equivalent diameter is less than or equal to 2.5 μm in ambient air. 3.2 Filtration efficiency It shall be able to generate non-oily particles and oily particles that meet the test requirements; it shall be able to neutralize the charge of the generated particles, and ensure that the particles are evenly distributed at the sampling port before filtration. 5.1.2.2 Non-oily particles Sodium chloride (NaCl) particles. The count median diameter (CMD) of the particle is 0.075 μm ± 0.020 μm; the geometric standard deviation of the particle size distribution is not greater than 1.86. The concentration of non-oily particles is set according to the product use environment. The concentration of general industrial products is not more than 200 mg/m3; the concentration of civil products is not more than 30 mg/m3. According to product needs, other test concentrations can also be set. 5.1.2.3 Oily particles Diisooctyl sebacate (DEHS), dioctyl phthalate (DOP) or other applicable oils (such as paraffin oil) particles. The count median diameter (CMD) of the particle is 0.185 μm ± 0.020 μm; the geometric standard deviation of the particle size distribution is not greater than 1.60. The concentration of oily particles is set according to the product use environment. The concentration of general industrial products is 50 mg/m3 ~ 200 mg/m3; the concentration of civil products is not more than 30 mg/m3. According to product needs, other test concentrations can also be set. 5.1.3 Test system 5.1.3.1 General requirements It shall include sample fixtures, photometers, pressure gauges and flow meters; the sampling frequency is ≥ 1 times/min; the detection range of filtration efficiency is 0% ~ 99.999%; the resolution is at least 0.003%. 5.1.3.2 Sample fixture It shall be made of corrosion-resistant metal materials and composed of upper and lower holders. The fixture shall ensure that the sample has a circular measured area of 100 cm2 ± 1 cm2, unless otherwise specified. There shall be no leakage at the edge of the sample after clamping; the used sealing ring shall not change the measured area of the sample. The surface of the fixture that is in contact with the test aerosol shall be clean, easy to clean, corrosion-resistant, conductive and grounded. 5.1.3.3 Photometer 7.2 Temperature and humidity pretreatment 7.2.1 Equipment The sample temperature and humidity pretreatment equipment requirements are as follows: a) The technical performance of the damp heat testing chamber shall meet the requirements of GB/T 10586; b) The technical performance of the high temperature test chamber shall meet the requirements of GB/T 11158; b) The technical performance of the low temperature test chamber shall meet the requirements of GB/T 10589; 7.2.2 Method Take the sample out of the original packaging and proceed as follows: a) Place it in an environment at 38.0 °C ± 2.5 °C, where the relative humidity is (85 ± 5) %, for 24 h ± 1 h; b) Place it in a dry environment at 70 °C ± 3 °C for 24 h ± 1 h; c) Place it in an environment at -30 °C ± 3 °C for 24 h ± 1 h. Before proceeding to the above-mentioned b) and c) treatment steps, the sample temperature shall be restored to room temperature for at least 4 h before proceeding to the subsequent steps. After the step c), the sample shall be placed in an airtight container and tested within 10 h. 7.3 Washing pretreatment According to the type-A standard washing machine in GB/T 8629-2017, washing procedure 4H, use standard detergent to continuously wash the sample 3 times; after washing, hang to dry. According to product standards or negotiated by interested parties, the number of washes can also be specified separately, which needs to be stated in the test report. 7.4 Sampling requirements 7.4.1 Sampling Cut a circular sample, whose diameter is at least 150 mm, uniformly from the fabric for filtration, or a square sample whose side length is at least 150 mm. 9.1.4 When performing a non-oily aerosol test, turn on the heater, to dry the aerosol to form NaCl particles. When performing an oily aerosol test, it’s unnecessary to turn on the heater. 9.1.5 After the instrument is turned on, it takes at least 30 min to make the instrument in a stable state. 9.2 Set air flow The air flow setting range shall be 0 L/min ~ 100 L/min. Under normal circumstances, the air flow of the mask is 85 L/min (if multiple filter elements are used, the flow shall be divided equally; for example, for dual filter elements, the detection air flow of each filter element shall be 42.5 L/min; if multiple filter elements are possible to be used separately, it shall be tested according to the detection conditions of a single filter element); the air flow rate of the filter fabric for the air filter is 32 L/min. The air flow rate can also be set according to product standard requirements or customer requirements, which must be given in the test report. 9.3 Start test 9.3.1 Mask 9.3.1.1 Place the sample on the sample fixture and fix it, so that the dust-facing surface of the sample faces the direction of the airflow; prevent the sample from twisting or edge gas leakage during the test. Note 1: Test the mask as a whole without damage. Note 2: A hot melt glue gun can be used to completely seal the breathing valve cover of the mask, so as to prevent gas leakage at the edge of the respirator valve. 9.3.1.2 Start the test button, and the gas will flow through the sample; observe and record the pre-test filtration efficiency E of the sample; the result is accurate to 0.1%. Use electronic pressure sensor or pressure gauge (5.1.3.4) to measure the pressure difference on both sides of the sample; obtain the initial resistance drop of the sample and record; the result is accurate to 0.1 Pa. Note: It takes about 15 s to measure the pre-test filtration efficiency E and the initial pressure drop. 9.3.1.3 Calculate the estimated filter time according to Formula (1); stop the test immediately after the actual test time reaches the estimated filter time T. Use the minimum filtration efficiency that is obtained during the entire filter time T as the filtration efficiency of the sample; the result is accurate to 0.1%. Note: Determine the final pressure drop according to product standards or negotiated by interested parties. 9.3.2.4 Test the remaining samples in sequence according to the requirements of 9.3.2.1 ~ 9.3.2.3.10 Test data processing10.1 Filtration efficiency Take the average value of the filtration efficiency of 3 samples as the test result of filtration efficiency of the sample; express in percentages (%). When the average value is less than 90%, retain the result to one decimal place; when the average value is 90% ~ 99%, retain the result to two decimal places; when the average value is greater than or equal to 99%, retain the result to three decimal places. 10.2 Initial pressure drop Use the average value of initial pressure drop of 3 samples as the test result of initial pressure drop of the sample, in Pascals (Pa); retain the result to one decimal place. 10.3 Filter time For the fabric for filtration, take the average of filter time of 3 samples as the test result of filter time of the sample, in minutes (min); retain the result to one decimal place. 10.4 Final pressure drop For the fabric for filtration, if the final pressure drop is selected to be twice the initial pressure drop, then, directly calculate twice the value of the initial pressure drop of 10.2, as the test result of final pressure drop of the sample, in Pascals (Pa); retain the result to one decimal place. If the final pressure drop is determined by the product standard or negotiated by interested parties, take the value as the test result, in Pascals (Pa); retain the result to one decimal place. 10.5 Dust-hold capacity For the fabric for filtration, respectively calculate the dust-hold capacity of each sample according to Formula (2); take the average of dust-hold capacity of 3 samples as the test result of dust-hold capacity of the sample; retain the result to one decimal place. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 38413-2019 be delivered?Answer: The full copy PDF of English version of GB/T 38413-2019 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 38413-2019_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 38413-2019_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 38413-2019 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of GB/T 38413-2019?A step-by-step guide to download PDF of GB/T 38413-2019_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 38413-2019". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |