GB/T 37505-2019 PDF EnglishUS$110.00 · In stock · Download in 9 seconds
GB/T 37505-2019: Surface active agents - Determination of quinoline content in dispersing agents Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
Similar standardsGB/T 37505-2019: Surface active agents - Determination of quinoline content in dispersing agents---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT37505-2019NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 71.100.40 G 72 Surface active agents - Determination of quinoline content in dispersing agents ISSUED ON: JUNE 04, 2019 IMPLEMENTED ON: MAY 01, 2020 Issued by: State Administration for Market Regulation; Standardization Administration of the People's Republic of China. Table of ContentsForeword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Principle ... 4 4 Reagents ... 4 5 Instruments and devices ... 5 6 Determination methods ... 6 7 Detection limit, recovery rate and precision ... 10 8 Test report ... 11 Annex A (informative) GC-FID chromatogram of quinoline standard product 12 Annex B (informative) GC-MS total ion chromatogram and mass spectrum of quinoline standard product ... 13 Surface active agents - Determination of quinoline content in dispersing agents1 ScopeThis Standard specifies the determination method for quinoline content in surface active dispersing agents. This Standard is applicable to various surface-active dispersing agents that are produced from coal chemical raw materials.2 Normative referencesThe following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682, Water for analytical laboratory use - Specification and test methods GB/T 8170, Rules of rounding off for numerical values & expression and judgement of limiting values GB/T 9722-2006, Chemical reagent - General rules for the gas chromatography3 PrincipleDisperse and dissolve the sample in water. Use ethyl acetate to extract the quinoline in it. Use gas chromatography or gas chromatography-mass spectrometry to detect. Use peak area external standard method to quantify.4 Reagents4.1 General provisions Unless otherwise stated, use analytical reagents that meet national standards. The test water shall meet the specifications for grade three water in GB/T 6682. 5.7 Organic phase needle filter The specification is 13mm × 0.45μm. 5.8 Pipette The capacity is 20mL.6 Determination methods6.1 Sample pre-treatment Weigh 0.5g of sample (to the nearest of 0.0001g). Place in the extractor (see 5.6). Add 20mLof water. Shake vigorously till dissolved or fully wetted and dispersed. Use the pipette (see 5.8) to accurately add 20mL of ethyl acetate (see 4.2). Shake the extractor for 0.5min to make the aqueous phase and the organic phase fully contact. It may also use ultrasonic-assisted extraction. Conduct static layering (if the emulsification is serious and the layering is slower, it can be centrifuged at 3000r/min for 10min). Take the supernatant. For the sample solution that is filtered through the organic phase needle filter (see 5.7), use gas chromatograph or GC/MS to analyze. If the sample concentration exceeds the linear range of the instrument, it needs to dilute the sample to the linear range. 6.2 Gas chromatography 6.2.1 Gas chromatography analysis conditions Since the test results depend on the instrument used, it is not possible to give general parameters for chromatographic analysis. It may choose the best analysis conditions according to different equipment. Use the following parameters that have been proved suitable for the test. The parameters are as follows: - Chromatographic column: HP-5, 30m × 0.32mm × 0.25μm, or equivalent; - Carrier gas: nitrogen, constant flow, flow rate of 1mL/min; - Inlet temperature: 270°C; - Detector (FID) temperature: 300°C; - Hydrogen flow: 40mL/min; - Air flow: 400mL/min; - Compensation gas: nitrogen, 30mL/min; milligrams per kilogram (mg/kg): Where, A - Peak area of quinoline in sample solution; V - Volume of sample solution, in milliliters (mL); a, b - Standard curve constants; m - Sample mass, in grams (g); F - Dilution factor. The calculation result is rounded off to the integer according to GB/T 8170. 6.3 Gas chromatography-mass spectrometry (arbitration method) 6.3.1 GC-MS analysis conditions Since the test results depend on the instrument used, it is not possible to give general parameters for chromatographic analysis. It may choose the best analysis conditions according to different equipment. Use the following parameters that have been proved suitable for the test. The parameters are as follows: - Chromatographic column: HP-5MS, 30m × 0.25mm × 0.25μm, or equivalent; - Carrier gas: nitrogen, constant flow, flow rate of 1mL/min; - Inlet temperature: 260°C; - Auxiliary interface temperature: 280°C; - Injection volume: 1μL; - Injection method: injection without flow division; - Heating program: maintain at 80°C for 2min, rise at 10°C/min to 180°C for 2min; - Solvent delay: 4min; - Ion source temperature: 230°C; Where, A - Quinoline quantitative ion peak area; c - Quinoline concentration, in milligrams per liter (mg/L); a, b - Standard curve constants. After each instrument maintenance or replacement of parts, it shall redraw the standard curve. It is recommended that before each test of sample solution, use the quinoline standard solution with a known concentration to verify the curve. When the error exceeds 5%, it shall redraw the standard curve. 6.3.4 Sample determination steps Analyze the sample solution that has been well processed according to the chromatographic conditions (see 6.3.1). Record the quinoline quantitative ion peak area A in the sample solution. 6.3.5 Result calculation The quinoline content in surface active agent is calculated according to formula (4). The quinoline content X in surface active agent is calculated according to formula (4), in milligrams per kilogram (mg/kg): A - Peak area of quinoline quantifier ion in sample solution; V - Volume of extract liquid, in milliliters (mL); a, b - Standard curve constants; m - Sample mass, in grams (g); F - Dilution factor. The calculation result is rounded off to the integer according to GB/T 8170.7 Detection limit, recovery rate and precision7.1 Detection limit GC-FID detection limit is 20mg/kg. GC-MS detection limit is 5mg/kg. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 37505-2019 be delivered?Answer: The full copy PDF of English version of GB/T 37505-2019 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 37505-2019_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 37505-2019_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 37505-2019 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of GB/T 37505-2019?A step-by-step guide to download PDF of GB/T 37505-2019_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 37505-2019". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |