Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 37040-2018 PDF English

US$135.00 · In stock · Download in 9 seconds
GB/T 37040-2018: Limit and determination of carcinogenic dyes in dye product
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
GB/T 37040-2018135 Add to Cart Auto, 9 seconds. Limit and determination of carcinogenic dyes in dye product Valid

Similar standards

GB/T 41071   GB/T 37280   GB/T 36908   GB/T 44009   

GB/T 37040-2018: Limit and determination of carcinogenic dyes in dye product

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT37040-2018
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 71.100.01;87.060.10 G 55 Limit and determination of carcinogenic dyes in dye product ISSUED ON: DECEMBER 28, 2018 IMPLEMENTED ON: NOVEMBER 01, 2019 Issued by: State Administration for Market Regulation; Standardization Administration of the People's Republic of China.

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Requirements ... 4 4 Principle ... 4 5 Test methods ... 5 6 Minimum detection limit, precision and recovery rate ... 9 7 Test report ... 9 Annex A (normative) Detection wavelength of HPLC-DAD method of carcinogenic dye and characteristic ion of HPLC-MS method ... 11 Annex B (informative) Schematic diagram of HPLC-DAD method chromatogram of standard working solution at different detection wavelengths ... 12 Limit and determination of carcinogenic dyes in dye product WARNING - The personnel using this Standard shall have practical experience in formal laboratory work. This Standard does not point out all possible safety issues. The user is responsible for taking appropriate safety and health measures and ensuring compliance with the conditions stipulated by relevant national laws and regulations.

1 Scope

This Standard specifies limits and determination methods of 12 carcinogenic dyes (see Annex A) in dye product. This Standard is applicable to various formulations of dye products.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682-2008, Water for analytical laboratory use - Specification and test methods (ISO 3696:1987, MOD) GB/T 8170-2008, Rules of rounding off for numerical values & expression and judgement of limiting values

3 Requirements

The content of each carcinogenic dye (see Annex A) in the dye product shall not exceed 150mg/kg.

4 Principle

After the sample is dissolved (or extracted), use high performance liquid chromatography-diode array detector (HPLC-DAD) to determine the nature; use peak area external standard method to quantify carcinogenic dyes. For Prepare the single-component carcinogenic dye standard stock methanol solution listed in Annex A of which the effective concentration is 200mg/L. Store it in the freezer of a refrigerator from light. It shall be valid for 1 year. 5.4.2 Standard working solution Group A: Take 0.5mL from the basic violet 14 standard stock solution and place it in a 50mL volumetric flask. Use methanol to dilute and set it to a constant volume. Group B: Respectively take 0.5mL from the remaining 11 standard stock solutions and place them in 50mL volumetric flasks. Standard working solution can be prepared into other suitable concentrations as required. Prepare when required. 5.5 Preparation of sample solution Methanol soluble dye: Weigh 0.5g of sample (to the nearest of 0.0001g). Place it in a 50mL volumetric flask. Use methanol to dissolve. Dilute and set it to a constant volume. Vibrate in an ultrasonic generator. Fully dissolve and make it ready for use. Methanol insoluble dye: Weigh 0.5g of sample (to the nearest of 0.0001g). Place it in a 100mL conical flask with grinding mouth stopper. Accurately add 50mL of methanol. In an ultrasonic generator, conduct 30min extraction. Cool to room temperature. Use 0.45μm PTFE membrane filter head to filter the extract for use. 5.6 Spectrum analysis 5.6.1 HPLC-DAD analysis method 5.6.1.1 HPLC-DAD chromatographic conditions 5.6.1.1.1 Since the test results depend on the instrument used, it is impossible to give general parameters for chromatographic analysis. The following parameters have been proved to be suitable for testing. It may, according to different instruments and equipment, select the best analysis conditions. 5.6.1.1.2 Chromatographic column: Stainless steel column of which the length is 150mm, the inner diameter is 3.9mm, the stationary phase is RP18, the particle size is 5μm. 5.6.1.1.3 Detection wavelength: 200nm~700nm. 5.6.1.1.4 Quantitative wavelength: 400nm, 500nm, 540nm, 590nm, 620nm. Turn on the liquid chromatography-mass spectrometer. After the various operating conditions of the instrument are stable, use a micro syringe to pipette 20μL of sample solution and standard working solutions A, B to respectively inject into injection valves. After the last component flows out (see Annex B), use chromatography workstation to process the result. Through characteristic ion and comparation on the retention time of the chromatographic peak of the sample and the standard sample, determine the nature. 5.7 Chromatogram Refer to Annex B for the liquid chromatogram of carcinogenic dyes determined by this method.

6 Minimum detection limit, precision and recovery rate

6.1 Minimum detection limit The minimum detection limit of each carcinogenic dye in this method is 10mg/kg. 6.2 Precision In the same laboratory, the same operator uses the same equipment according to the same test method. Within a short time, independently test the same testing object. The absolute difference between the two independent test results obtained is not more than 10% of its arithmetic mean. 6.3 Recovery rate Use standard addition method. Add 1mL of the standard stock solution to the sample that has been determined by this method not contain carcinogenic dyes. Operate according to Clause 5. The measured recovery rate of carcinogenic dyes shall be 70%~130%.

7 Test report

The test report shall at least give the following information: a) Sample description; b) Standard reference number used; c) Test result; d) Deviation from standard; ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of GB/T 37040-2018 be delivered?Answer: The full copy PDF of English version of GB/T 37040-2018 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 37040-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 37040-2018_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 37040-2018 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of GB/T 37040-2018?

A step-by-step guide to download PDF of GB/T 37040-2018_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 37040-2018".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9